Rapid-prototyped PLGA/β-TCP/hydroxyapatite nanocomposite scaffolds in a rabbit femoral defect model
The DOI matches its Crossref record.
Abstract
Bone tissue engineering scaffolds composed of poly(d,l-lactide:glycolide) (DL-PLGA) and β-tricalcium phosphate (β-TCP) nanocomposites were prepared and characterized. Scaffolds with two specific architectures were produced via fused deposition modeling (FDM), a type of extrusion freeform fabrication. Microfilaments deposited at angles of 0° and 90° were designated as the 'simple' scaffold architecture, while those deposited at angles alternating between 0°, 90°, 45° and -45° were designated as the 'complex' scaffold architecture. In addition, the simple and complex scaffolds were coated with hydroxyapatite (HA). The surface morphology of the scaffolds was assessed before and after HA coating and uniform distribution of HA coating on the surface was observed by scanning electron microscopy. The scaffolds were implanted into rabbit femoral unicortical bone defects according to four treatment groups based on pore structure and HA coating. After 6 and 12 weeks, scaffolds and host bone were recovered and processed for histology. Data suggest that all configurations of the scaffolds integrated with the host bone and were biocompatible and thus may offer an exciting new scaffold platform for delivery of biologicals for bone regeneration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
3D printing of polymer matrix composites: A review and prospective
Wang, X., Jiang, M., Zhou, Z., Gou, J., & Hui, D. (2017) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2016.11.034 · Cited by 3,325
Recent advances in 3D printing of biomaterials
Chia, H. N., & Wu, B. M. (2015) · Journal of Biological Engineering · doi:10.1186/s13036-015-0001-4 · Cited by 1,734
Additive manufacturing of biomaterials
Bose, S., Ke, D., Sahasrabudhe, H., & Bandyopadhyay, A. (2018) · Progress in Materials Science · doi:10.1016/j.pmatsci.2017.08.003 · Cited by 738
A critical review on the fused deposition modeling of thermoplastic polymer composites
Penumakala, P. K., Santo, J., & Thomas, A. (2020) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2020.108336 · Cited by 704
Fused deposition modeling: process, materials, parameters, properties, and applications
Rajan, K., Samykano, M., Kadirgama, K., Harun, W. S. W., & Rahman, M. M. (2022) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-022-08860-7 · Cited by 426
Metadata
- Authors
- Kim, J., McBride, S., Tellis, B., Alvarez-Urena, P., Song, Y.-H., Dean, D. D., Sylvia, V. L., Elgendy, H., Ong, J., & Hollinger, J. O.
- Venue
- Biofabrication
- Publisher
- IOP Publishing
- Published
- 2012-03-19
- Volume
- 4
- Issue
- 2
- Pages
- 025003
- ISSN
- 1758-5082 (ISSN-L)
- 1758-5090
- OpenAlex
- W2096824872
- Cited by
- 153
- References
- 0
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid-prototyped PLGA/β-TCP/hydroxyapatite nanocomposite scaffolds in a rabbit femoral defect model. https://app.cochat.ai/papers/10.1088/1758-5082/4/2/025003
- The paper
- Kim, J., McBride, S., Tellis, B., Alvarez-Urena, P., Song, Y.-H., Dean, D. D., Sylvia, V. L., Elgendy, H., Ong, J., & Hollinger, J. O. (2012). Rapid-prototyped PLGA/β-TCP/hydroxyapatite nanocomposite scaffolds in a rabbit femoral defect model. Biofabrication. https://doi.org/10.1088/1758-5082/4/2/025003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.