Mechanical characterization of bioprinted in vitro soft tissue models
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Recent development in bioprinting technology enables the fabrication of complex, precisely controlled cell-encapsulated tissue constructs. Bioprinted tissue constructs have potential in both therapeutic applications and nontherapeutic applications such as drug discovery and screening, disease modelling and basic biological studies such as in vitro tissue modelling. The mechanical properties of bioprinted in vitro tissue models play an important role in mimicking in vivo the mechanochemical microenvironment. In this study, we have constructed three-dimensional in vitro soft tissue models with varying structure and porosity based on the 3D cell-assembly technique. Gelatin/alginate hybrid materials were used as the matrix material and cells were embedded. The mechanical properties of these models were assessed via compression tests at various culture times, and applicability of three material constitutive models was examined for fitting the experimental data. An assessment of cell bioactivity in these models was also carried out. The results show that the mechanical properties can be improved through structure design, and the compression modulus and strength decrease with respect to time during the first week of culture. In addition, the experimental data fit well with the Ogden model and experiential function. These results provide a foundation to further study the mechanical properties, structural and combined effects in the design and the fabrication of in vitro soft tissue models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The design of scaffolds for use in tissue engineering. Part I. Traditional factors
Yang, S., Leong, K.-F., Du, Z., & Chua, C.-K. (2001) · Tissue Engineering · doi:10.1089/107632701753337645 · Cited by 2,234
Three-Dimensional Photopatterning of Hydrogels Containing Living Cells
Liu, V. A., & Bhatia, S. N. (2002) · Biomedical Microdevices · doi:10.1023/a:1020932105236 · Cited by 399
Cited by
3D bioprinting for engineering complex tissues
Mandrycky, C., Wang, Z., Kim, K., & Kim, D.-H. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.12.011 · Cited by 1,754
Bioinks for 3D bioprinting: an overview
Gungor-Ozkerim, P. S., Inci, I., Zhang, Y. S., Khademhosseini, A., & Dokmeci, M. R. (2018) · Biomaterials Science · doi:10.1039/c7bm00765e · Cited by 1,428
Progress in 3D bioprinting technology for tissue/organ regenerative engineering
Matai, I., Kaur, G., Seyedsalehi, A., McClinton, A., & Laurencin, C. T. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2019.119536 · Cited by 1,156
Crosslinking Strategies for 3D Bioprinting of Polymeric Hydrogels
GhavamiNejad, A., Ashammakhi, N., Wu, X. Y., & Khademhosseini, A. (2020) · Small · doi:10.1002/smll.202002931 · Cited by 400
Bioprinting and its applications in tissue engineering and regenerative medicine
Aljohani, W., Ullah, M. W., Zhang, X., & Yang, G. (2018) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2017.08.171 · Cited by 335
Metadata
- Authors
- Zhang, T., Yan, K. C., Ouyang, L., & Sun, W.
- Venue
- Biofabrication
- Publisher
- IOP Publishing
- Published
- 2013-11-26
- Volume
- 5
- Issue
- 4
- Pages
- 045010
- ISSN
- 1758-5082 (ISSN-L)
- 1758-5090
- OpenAlex
- W2050866007
- Cited by
- 79
- References
- 2
- FWCI
- 2.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.