CoChat

Enabling peristalsis of human colon tumor organoids on microfluidic chips

Open access

The DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.

Abstract

Peristalsis in the digestive tract is crucial to maintain physiological functions. It remains challenging to mimic the peristaltic microenvironment in gastrointestinal organoid culture. Here, we present a method to model the peristalsis for human colon tumor organoids on a microfluidic chip. The chip contains hundreds of lateral microwells and a surrounding pressure channel. Human colon tumor organoids growing in the microwell were cyclically contracted by pressure channel, mimicking the in vivo mechano-stimulus by intestinal muscles. The chip allows the control of peristalsis amplitude and rhythm and the high throughput culture of organoids simultaneously. By applying 8% amplitude with 8 ∼ 10 times min −1 , we observed the enhanced expression of Lgr5 and Ki67. Moreover, ellipticine-loaded polymeric micelles showed reduced uptake in the organoids under peristalsis and resulted in compromised anti-tumor efficacy. The results indicate the importance of mechanical stimuli mimicking the physiological environment when using in vitro models to evaluate nanoparticles. This work provides a method for attaining more reliable and representative organoids models in nanomedicine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1758-5090/ac2ef9

Cites

68 of 68 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 68 references

Cited by

Metadata

Authors
Fang, G., Lu, H., Al-Nakashli, R., Chapman, R., Zhang, Y., Ju, L. A., Lin, G., Stenzel, M. H., & Jin, D.
Affiliations
  • University of Technology Sydney (AU)
  • UNSW Sydney (AU)
  • University of Newcastle Australia (AU)
  • The University of Sydney (AU)
Venue
Biofabrication
Published
2021-10-25
Volume
14
Issue
1
Pages
015006
ISSN
  • 1758-5082 (ISSN-L)
  • 1758-5090
OpenAlex
W3206340469
Cited by
77
References
68
Citations by year
2026: 6 · 2025: 17 · 2024: 20 · 2023: 25 · 2022: 8 · 2021: 1
FWCI
4.11
Type
journal article
Language
en
Open access
Licence
Locations
  • Biofabrication (publishedVersion)
  • PubMed (publishedVersion)
  • NOVA (University of Newcastle Australia) (submittedVersion)
Funders
  • ARC Linkage Infrastructure, Equipment and Facilities (LIEF) Project (LE180100043)
  • China Scholarship Council (201708140082)
  • ARC Industry Transformational Research Hub Scheme (IH150100028)
  • Science and Technology Cooperation Fund between Chinese and Australian Governments (2017YFE0132300)
  • National Health and Medical Research Council (GNT1160635)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
peristalsis, microfluidics, microwells, mechanical stimulation, Lgr5, Ki-67, ellipticine, polymeric micelles, nanoparticle uptake, antitumor efficacy, nanomedicine, in vitro tumor model
MeSH terms
Colonic Neoplasms, Humans, Organoids, Peristalsis, Microfluidics, Lab-On-A-Chip Devices, Tumor Microenvironment

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.