Cited by 11Atomic and Subatomic Physics ResearchQuantum Information and CryptographyMechanical and Optical Resonators

A modular optically pumped magnetometer system

Open access
Coussens, T, Gialopsou, A, Abel, C, Bason, M G, James, T M, Evans, W, Woodley, M T M, Nightingale, D +4 more·2024·Quantum Science and Technology

Abstract

To address the demands in healthcare and industrial settings for spatially resolved magnetic imaging, we present a modular optically pumped magnetometer (OPM) system comprising a multi-sensor array of highly sensitive quantum magnetometers. This system is designed and built to facilitate fast prototyping and testing of new measurement schemes by enabling quick reconfiguration of the self-contained laser and sensor modules as well as allowing for the construction of various array layouts with a shared light source. The modularity of this system facilitates the development of methods for managing high-density arrays for magnetic imaging. The magnetometer sensitivity and bandwidth are first characterised in both individual channel and differential gradiometer configurations before testing in a real-world magnetoencephalography environment by measuring alpha rhythms from the brain of a human participant. We demonstrate the OPM system in a first-order axial gradiometer configuration with a magnetic field gradient sensitivity of 10 fT / cm / Hz at a baseline of 4.5 cm. Single-channel operation achieved a sensitivity of 65 fT / Hz . Bandwidths exceeding 200 Hz were achieved for two independent modules. The system’s increased temporal resolution allows for the measurement of spinal cord signals, which we demonstrate by using phantom signal trials and comparing with an existing commercial sensor.

Integrity signals

Registry

Crossref · 10.1088/2058-9565/ad4e60

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Coussens, T., Gialopsou, A., Abel, C., Bason, M. G., James, T. M., Evans, W., Woodley, M. T. M., Nightingale, D., Nicolau, D., Page, L., Oručević, F., & Krüger, P.
Affiliations
  • Physikalisch-Technische Bundesanstalt (DE)
  • Brighton and Sussex Medical School (GB)
  • University of Sussex (GB)
  • Rutherford Appleton Laboratory (GB)
Venue
Quantum Science and Technology
Published
2024-06-19
Volume
9
Issue
3
Pages
035045
ISSN
2058-9565 (ISSN-L)
OpenAlex
W4398159183
Cited by
11
References
4
Citations by year
2026: 5 · 2025: 4 · 2024: 2
FWCI
1.75
Type
journal article
Language
en
Open access
Locations
  • Quantum Science and Technology (publishedVersion, cc-by)
  • arXiv (Cornell University) (submittedVersion)
  • Figshare (submittedVersion, cc-by)
  • Science and Technology Facilities Council (submittedVersion, cc-by)
  • arXiv (Cornell University)
Funders
  • University of Sussex Strategic Development Fund
  • Engineering and Physical Sciences Research Council (EP/T001046/1)
  • Innovate UK (42186)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
  • Physical Sciences › Computer Science › Artificial Intelligence › Quantum Information and Cryptography
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Mechanical and Optical Resonators
Keywords
optically pumped magnetometers, quantum magnetometers, multi-sensor array, magnetic imaging, magnetoencephalography, alpha rhythm, axial gradiometer, magnetometer sensitivity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review