The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
High-sensitivity operation of single-beam optically pumped magnetometer in a kHz frequency range
Open accessAbstract
Optically pumped magnetometers (OPM) can be used in various applications, from magnetoencephalography to magnetic resonance imaging and nuclear quadrupole resonance (NQR). OPMs provide high sensitivity and have the significant advantage of non-cryogenic operation. To date, many magnetometers have been demonstrated with sensitivity close to 1 fT, but most devices are not commercialized. Most recently, QuSpin developed a model of OPM that is low cost, high sensitivity, and convenient for users, which operates in a single-beam configuration. Here we developed a theory of single-beam (or parallel two-beam) magnetometers and showed that it is possible to achieve good sensitivity beyond their usual frequency range by tuning the magnetic field. Experimentally we have tested and optimized a QuSpin OPM for operation in the frequency range from DC to 1.7 kHz, and found that the performance was only slightly inferior despite the expected decrease due to deviation from the spin-exchange relaxation-free regime.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“OPMs on the other hand, like the QZFM series by QuSpin (QuSpin Inc., Louisville, CO, USA), represent a promising, emerging technology that combines near-SQUID sensitivity with room-temperature operation while offering scalability towards wearable and multi-subject recording [25,26,44,45].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [44]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Induction coil sensors—a review
Tumanski, S. (2007) · Measurement Science and Technology · doi:10.1088/0957-0233/18/3/r01 · Cited by 590
Improved Limit on the Permanent Electric Dipole Moment ofHg199
Griffith, W. C., Swallows, M. D., Loftus, T. H., Romalis, M. V., Heckel, B. R., & Fortson, E. N. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.101601 · Cited by 489
Tunable Atomic Magnetometer for Detection of Radio-Frequency Magnetic Fields
Savukov, I. M., Seltzer, S. J., Romalis, M. V., & Sauer, K. L. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.063004 · Cited by 313
Self-citationSpin-exchange relaxation-free magnetometry using elliptically polarized light
Shah, V., & Romalis, M. V. (2009) · Physical Review A · doi:10.1103/physreva.80.013416 · Cited by 273
Self-citationNMR Detection with an Atomic Magnetometer
Savukov, I. M., & Romalis, M. V. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.123001 · Cited by 250
Self-citationSubfemtotesla radio-frequency atomic magnetometer for detection of nuclear quadrupole resonance
Lee, S.-K., Sauer, K. L., Seltzer, S. J., Alem, O., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2390643 · Cited by 176
Magnetic resonance imaging with an optical atomic magnetometer
Xu, S., Yashchuk, V. V., Donaldson, M. H., Rochester, S. M., Budker, D., & Pines, A. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0605396103 · Cited by 168
Detection of NMR signals with a radio-frequency atomic magnetometer
Savukov, I., Seltzer, S. J., & Romalis, M. V. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.12.012 · Cited by 153
Self-citation
Cited by
Tang, J., Zhai, Y., Li, C., Zhang, Y., Li, L., Zhao, B., Zhou, B., Han, B., & Liu, G. (2021) · Optics Express · doi:10.1364/oe.425851 · Cited by 125
Miniaturized Magnetic Sensors for Implantable Magnetomyography
Zuo, S., Heidari, H., Farina, D., & Nazarpour, K. (2020) · Advanced Materials Technologies · doi:10.1002/admt.202000185 · Cited by 114
Parameter Modeling Analysis of a Cylindrical Ferrite Magnetic Shield to Reduce Magnetic Noise
Ma, D., Lu, J., Fang, X., Yang, K., Wang, K., Zhang, N., Han, B., & Ding, M. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3050351 · Cited by 99
Quantum‐Based Magnetic Field Sensors for Biosensing
Bao, B., Hua, Y., Wang, R., & Li, D. (2023) · Advanced Quantum Technologies · doi:10.1002/qute.202200146 · Cited by 108
Three-axis closed-loop optically pumped magnetometer operated in the SERF regime
Yan, Y., Lu, J., Zhang, S., Lu, F., Yin, K., Wang, K., Zhou, B., & Liu, G. (2022) · Optics Express · doi:10.1364/oe.458367 · Cited by 89
Metadata
- Authors
- Savukov, I., Kim, Y. J., Shah, V, & Boshier, M. G.
- Affiliations
- Los Alamos National Laboratory (US)
- QuSpin (United States) (US)
- Corresponding author
- Savukov, I
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2017-02-02
- Volume
- 28
- Issue
- 3
- Pages
- 035104
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2573282927
- Cited by
- 86
- References
- 21
- Citations by year
- 2026: 7 · 2025: 9 · 2024: 12 · 2023: 10 · 2022: 17 · 2021: 14 · 2020: 6 · 2019: 8 · 2018: 3
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- creativecommons.org/licenses/by/3.0/ (vor)
- Locations
- Measurement Science and Technology (publishedVersion, cc-by)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- U.S. DOE through the LANL/LDRD
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Mechanical and Optical Resonators
- Keywords
- optically pumped magnetometers, high sensitivity, magnetic field tuning
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-sensitivity operation of single-beam optically pumped magnetometer in a kHz frequency range. https://app.cochat.ai/papers/10.1088/1361-6501/aa58b4
- The paper
- Savukov, I., Kim, Y. J., Shah, V, & Boshier, M. G. (2017). High-sensitivity operation of single-beam optically pumped magnetometer in a kHz frequency range. Measurement Science and Technology. https://doi.org/10.1088/1361-6501/aa58b4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.