The DOI matches its Crossref record.
Characterization of Nasal Spray Pumps and Deposition Pattern in a Replica of the Human Nasal Airway
Abstract
Deposition patterns are described of a nasal spray formulation for a novel rhinovirus protease inhibitor. These patterns, which were generated from different nasal spray pumps, were characterized using a multisectional nasal airway model. A human nasal replica was made from an in vivo magnetic resonance imaging (MRI) scan of an adult male human. The nasal replica consisted of 77 acrylic plastic sections, 1.5-mm thick. Our data showed that the aerosols were deposited mainly in the anterior and turbinate regions with little passing beyond the nasopharyngeal region. Detailed deposition information from the turbinate region indicated that deposition was high toward the anterior portion where most deposition was concentrated on the inferior meatus. Spray droplets were also deposited in spots of the middle and posterior portions of the turbinate region, and this nonuniform deposition pattern may be correlated with the flow pattern. The spray angle and droplet size of the nasal spray were found to be important in influencing the deposition pattern in the nasal airway. The droplet size was determined by a laser-diffraction technique and the spray angle by high-speed photography. Larger droplets and a wider spray angle increased deposition in the anterior region of the nasal airway, which prevented more material from depositing in the turbinate region.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guastella, A. J., Hickie, I. B., McGuinness, M. M., Otis, M., Woods, E. A., Disinger, H. M., Chan, H.-K., Chen, T. F., & Banati, R. B. (2013) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2012.11.019 · Cited by 357
Kelly, J. T., Asgharian, B., Kimbell, J. S., & Wong, B. A. (2004) · Aerosol Science and Technology · doi:10.1080/027868290883360 · Cited by 294
Wingrove, J., Swedrowska, M., Scherließ, R., Parry, M., Ramjeeawon, M., Taylor, D., Gauthier, G., Brown, L., Amiel, S., Zelaya, F., et al. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.03.032 · Cited by 67
Metadata
- Authors
- Cheng, Y. S., Holmes, T. D., Gao, J., Guilmette, R. A., Li, S., Surakitbanharn, Y., & Rowlings, C.
- Venue
- Journal of Aerosol Medicine
- Publisher
- SAGE Publications
- Published
- 2001-06
- Volume
- 14
- Issue
- 2
- Pages
- 267-280
- ISSN
- 0894-2684 (ISSN-L)
- 1557-9026
- OpenAlex
- W2099525843
- Cited by
- 233
- References
- 0
- FWCI
- 3.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of Nasal Spray Pumps and Deposition Pattern in a Replica of the Human Nasal Airway. https://app.cochat.ai/papers/10.1089/08942680152484199
- The paper
- Cheng, Y. S., Holmes, T. D., Gao, J., Guilmette, R. A., Li, S., Surakitbanharn, Y., & Rowlings, C. (2001). Characterization of Nasal Spray Pumps and Deposition Pattern in a Replica of the Human Nasal Airway. Journal of Aerosol Medicine. https://doi.org/10.1089/08942680152484199
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.