CoChat

Clinical Comparison of Whole-Body Radioiodine Scan and Serum Thyroglobulin After Stimulation with Recombinant Human Thyrotropin

Haugen, Bryan R., Ridgway, E. Chester, McLaughlin, Beverly A., McDermott, Michael T. · 2002 · Thyroid
Cited by 98

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Sensitive monitoring for thyroid cancer recurrence or persistence includes whole-body radioiodine scanning (WBS) and measurement of serum thyroglobulin (Tg) after endogenous or exogenous thyrotropin (TSH) stimulation. We reviewed our experience using recombinant human thyrotropin (rhTSH) in 83 patients to compare the clinical relevance of a positive WBS and/or Tg. Ten patients had a positive WBS; eight of these patients had activity limited to the thyroid bed. rhTSH-stimulated Tg was 2 ng/mL or more in 25 and 5 ng/mL or more in 13 patients. Of the patients with a negative WBS, 11 of 20 patients with a Tg 2 ng/mL or more and 7 of 9 patients with a Tg 5 ng/mL or more received therapy or further evaluation based on the Tg alone. Conversely, only 1 of 5 patients with a serum Tg less than 2 ng/mL received therapy or further evaluation based on a positive WBS alone. Three of the patients who did not receive therapy or further evaluation, had subsequent negative WBS 10-12 months later, suggesting lack of clinically significant disease. Twenty patients had a negative WBS and serum Tg 2 ng/mL or more. Eleven of 20 patients had a Tg less than 5 ng/mL and 4 of these patients had further evaluation with a neck ultrasound. One patient had a biopsy-proven recurrence (rhTSH-stimulated Tg 4 ng/mL). Subsequent evaluations (> or = 6 months later) have been negative for 8 patients. Of the nine patients with a Tg 5 ng/mL or more and a negative WBS, 7 had further evaluation and 6 of 7 had identified disease. In summary, rhTSH-stimulated WBS and Tg are complementary, but Tg is a more sensitive indicator of disease recurrence or persistence. In our practice, an rhTSH-stimulated Tg greater than 4-5 ng/mL often resulted in further evaluation, while a Tg less than 4 ng/mL rarely resulted in further immediate evaluation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/105072502753451959

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 98

Metadata

Authors
Haugen, B. R., Ridgway, E. C., McLaughlin, B. A., & McDermott, M. T.
Venue
Thyroid
Published
2002-01
Volume
12
Issue
1
Pages
37-43
ISSN
  • 1050-7256 (ISSN-L)
  • 1557-9077
OpenAlex
W1968467130
Cited by
98
References
1
FWCI
5.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical Comparison of Whole-Body Radioiodine Scan and Serum Thyroglobulin After Stimulation with Recombinant Human Thyrotropin. https://app.cochat.ai/papers/10.1089/105072502753451959
The paper
Haugen, B. R., Ridgway, E. C., McLaughlin, B. A., & McDermott, M. T. (2002). Clinical Comparison of Whole-Body Radioiodine Scan and Serum Thyroglobulin After Stimulation with Recombinant Human Thyrotropin. Thyroid. https://doi.org/10.1089/105072502753451959

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.