Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 283

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Tissue-Engineered Fabrication of an Osteochondral Composite Graft Using Rat Bone Marrow-Derived Mesenchymal Stem Cells

Gao, Jizong, Dennis, James E., Solchaga, Luis A., Awadallah, Amad S., Goldberg, Victor M., Caplan, Arnold I.·2001·Tissue Engineering

Abstract

This study tested the tissue engineering hypothesis that construction of an osteochondral composite graft could be accomplished using multipotent progenitor cells and phenotype-specific biomaterials. Rat bone marrow-derived mesenchymal stem cells (MSCs) were culture-expanded and separately stimulated with transforming growth factor-beta1 (TGF-beta1) for chondrogenic differentiation or with an osteogenic supplement (OS). MSCs exposed to TGF-beta1 were loaded into a sponge composed of a hyaluronan derivative (HYAF-11) for the construction of the cartilage component of the composite graft, and MSCs exposed to OS were loaded into a porous calcium phosphate ceramic component for bone formation. Cell-loaded HYAFF-11 sponge and ceramic were joined together with fibrin sealant, Tisseel, to form a composite osteochondral graft, which was then implanted into a subcutaneous pocket in syngeneic rats. Specimens were harvested at 3 and 6 weeks after implantation, examined with histology for morphologic features, and stained immunohistochemically for type I, II, and X collagen. The two-component composite graft remained as an integrated unit after in vivo implantation and histologic processing. Fibrocartilage was observed in the sponge, and bone was detected in the ceramic component. Observations with polarized light indicated continuity of collagen fibers between the ceramic and HYAFF-11 components in the 6-week specimens. Type I collagen was identified in the neo-tissue in both sponge and ceramic, and type II collagen in the fibrocartilage, especially the pericellular matrix of cells in the sponge. These data suggest that the construction of a tissue-engineered composite osteochondral graft is possible with MSCs and different biomaterials and bioactive factors that support either chondrogenic or osteogenic differentiation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/10763270152436427

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 283

Metadata

Authors
Gao, J., Dennis, J. E., Solchaga, L. A., Awadallah, A. S., Goldberg, V. M., & Caplan, A. I.
Venue
Tissue Engineering
Published
2001-08
Volume
7
Issue
4
Pages
363-371
ISSN
  • 1076-3279 (ISSN-L)
  • 1557-8690
OpenAlex
W2017544519
Cited by
283
References
34
FWCI
12.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tissue-Engineered Fabrication of an Osteochondral Composite Graft Using Rat Bone Marrow-Derived Mesenchymal Stem Cells. https://app.cochat.ai/papers/10.1089/10763270152436427
The paper
Gao, J., Dennis, J. E., Solchaga, L. A., Awadallah, A. S., Goldberg, V. M., & Caplan, A. I. (2001). Tissue-Engineered Fabrication of an Osteochondral Composite Graft Using Rat Bone Marrow-Derived Mesenchymal Stem Cells. Tissue Engineering. https://doi.org/10.1089/10763270152436427

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.