Tissue Reaction to Polypyrrole-Coated Polyester Fabrics: An in Vivo Study in Rats
The DOI matches its Crossref record.
Abstract
Electrically conductive polypyrrole is very attractive for tissue engineering because of its potential to modulate cellular activities through electrical stimulation. However, its in vivo behaviors have not been fully studied. This paper investigates the in vivo biocompatibility and biostability of PPy-coated polyester fabrics. Three PPy-coated fabrics were prepared using phosphonylation (PPy-Phos), plasma activation (PPy-Plas), and plasma activation plus heparin treatment (PPy-Plas-HE). Virgin and fluoropassivated fabrics (F-PET) were controls. The specimens were implanted subcutaneously in the back of rats for 3-90 days, then harvested and processed for enzymatic, histological, and morphological analyses. A noninvasive MRI method was used to continuously monitor the inflammation. The level of acid and alkaline phosphatase showed a similar or a less intensive cellular reaction by the PPy-coated fabrics, when compared to the controls. Histology supported the enzymatic results and showed a fast collagen infiltration at 28 days for the PPy-Phos fabric. MRI reported an overall decrease of inflammation over time, with the PPy-coated fabrics showing a similar or mild inflammation in contrast to the non-coated fabrics. PPy clusters and excessive PPy laminary coating on the PPy-Plas and PPy-Plas-HE were lost with the implantation. This experiment suggests a similar in vivo biocompatibility of the PPy-coated and noncoated polyester fabrics and the importance of achieving a thin, uniform PPy coating.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Conductive polymers: Towards a smart biomaterial for tissue engineering
Balint, R., Cassidy, N. J., & Cartmell, S. H. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.015 · Cited by 1,777
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Biodegradable synthetic polymers: Preparation, functionalization and biomedical application
Tian, H., Tang, Z., Zhuang, X., Chen, X., & Jing, X. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.06.004 · Cited by 1,293
Electrospinning polyaniline-contained gelatin nanofibers for tissue engineering applications
Li, M., Guo, Y., Wei, Y., MacDiarmid, A. G., & Lelkes, P. I. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.037 · Cited by 856
Polypyrrole-coated electrospun PLGA nanofibers for neural tissue applications
Lee, J. Y., Bashur, C. A., Goldstein, A. S., & Schmidt, C. E. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.04.042 · Cited by 735
Metadata
- Authors
- Jiang, X., Marois, Y., Traoré, A., Tessier, D., Dao, L. H., Guidoin, R., & Zhang, Z.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2002-08
- Volume
- 8
- Issue
- 4
- Pages
- 635-647
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2175063949
- Cited by
- 124
- References
- 0
- FWCI
- 4.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tissue Reaction to Polypyrrole-Coated Polyester Fabrics: An in Vivo Study in Rats. https://app.cochat.ai/papers/10.1089/107632702760240553
- The paper
- Jiang, X., Marois, Y., Traoré, A., Tessier, D., Dao, L. H., Guidoin, R., & Zhang, Z. (2002). Tissue Reaction to Polypyrrole-Coated Polyester Fabrics: An in Vivo Study in Rats. Tissue Engineering. https://doi.org/10.1089/107632702760240553
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.