The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Tissue Engineering Using Magnetite Nanoparticles and Magnetic Force: Heterotypic Layers of Cocultured Hepatocytes and Endothelial Cells
Abstract
Novel technologies to establish three-dimensional, in vivo-like tissue consisting of various types of cells are required for tissue engineering. We applied magnetic force to construct a heterotypic, layered coculture system of rat hepatocytes and human aortic endothelial cells (HAECs) that was not limited by cell type. Magnetite cationic liposomes carrying a positive surface charge to improve adsorption accumulated in HAECs at a concentration of 38 pg of magnetite per cell. Magnetically labeled HAECs specifically accumulated onto hepatocyte monolayers at sites where a magnet (4000 G) was positioned, and then adhered to form a heterotypic, layered construct with tight and close contact. This cocultured construct significantly (p < 0.05) enhanced albumin secretion by hepatocytes compared with that in homotypic cultures of hepatocytes or heterotypic cocultures of hepatocytes and HAECs without magnets. These results suggest that this novel use of magnetite nanoparticles and magnetic force, which we refer to as "magnetic force-based tissue engineering" (Mag-TE), offers a major advancement in tissue engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bhatia, S. N., Balis, U. J., Yarmush, M. L., & Toner, M. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.14.1883 · Cited by 890
Cited by
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Medical application of functionalized magnetic nanoparticles
Ito, A., Shinkai, M., Honda, H., & Kobayashi, T. (2005) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.100.1 · Cited by 1,470
Self-citationInnovation in Layer-by-Layer Assembly
Richardson, J. J., Cui, J., Björnmalm, M., Braunger, J. A., Ejima, H., & Caruso, F. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00627 · Cited by 922
Advances in Magnetic Nanoparticles for Biomedical Applications
Cardoso, V. F., Francesko, A., Ribeiro, C., Bañobre‐López, M., Martins, P., & Lanceros‐Mendez, S. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700845 · Cited by 723
Iron Oxide Nanoparticles for Magnetically-Guided and Magnetically-Responsive Drug Delivery
Estelrich, J., Escribano, E., Queralt, J., & Busquets, M. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16048070 · Cited by 532
Metadata
- Authors
- Ito, A., Takizawa, Y., Honda, H., Hata, K.-I., Kagami, H., Ueda, M., & Kobayashi, T.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2004-05
- Volume
- 10
- Issue
- 5-6
- Pages
- 833-840
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2126147099
- Cited by
- 197
- References
- 1
- FWCI
- 9.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tissue Engineering Using Magnetite Nanoparticles and Magnetic Force: Heterotypic Layers of Cocultured Hepatocytes and Endothelial Cells. https://app.cochat.ai/papers/10.1089/1076327041348301
- The paper
- Ito, A., Takizawa, Y., Honda, H., Hata, K.-I., Kagami, H., Ueda, M., & Kobayashi, T. (2004). Tissue Engineering Using Magnetite Nanoparticles and Magnetic Force: Heterotypic Layers of Cocultured Hepatocytes and Endothelial Cells. Tissue Engineering. https://doi.org/10.1089/1076327041348301
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.