CoChat

The Effect of Decreasing Digital Image Resolution on Teledermatology Diagnosis

Vidmar, Dennis A., Cruess, David, Hsieh, Paul, Dolecek, Quentin, Pak, Hon, Gwynn, Marjorie, Maggio, Kurt, Montemorano, Andrew, Powers, James, Richards, David, Sperling, Leonard, Wong, Henry, Yeager, Josef · 1999 · Telemedicine Journal
Cited by 33

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To determine the effect of degraded digital image resolution (as viewed on a monitor) on the accuracy and confidence of dermatologic interpretation. MATERIALS AND METHODS: Eight dermatologists interpreted 180 clinical cases divided into three Logical Competitor Sets (LCS) (pigmented lesions, non-pigmented lesions, and inflammatory dermatoses). Each case was digitized at three different resolutions. The images were randomized and divided into (9) 60-image sessions. The physicians were completely blinded concerning the image resolution. After 60 seconds per image, the viewer recorded a diagnosis and level of confidence. The resultant ROC curves compared the effect of LCS, level of clinical difficulty, and resolution of the digital image. One-way analysis of variance (ANOVA) compared the curves. RESULTS: The areas beneath the ROC curves did not demonstrate any consistently significant difference between the digital image resolutions for all LCS and levels of difficulty. The only significant effect observed was amongst pigmented lesions (LCS-A) where the ROC curve area was significantly smaller in the easy images at high resolution compared to low and medium resolutions. For all other ROC curve comparisons within LCS-A, at all other levels of difficulty, as well as within the other LCS at all levels of difficulty, none of the differences was significant. CONCLUSION: A 720 x 500 pixel image can be considered equivalent to a 1490 x 1000 pixel image for most store-and-forward teledermatology consultations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/107830299311943

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 8

  1. 10.1016/0190-9622(91)70178-5 · DOI
  2. Sneiderman CA, 1991, J Biocommun, 18, 22
  3. 10.1001/archderm.128.3.357 · DOI
  4. 10.1001/archderm.131.3.292 · doi:10.1001/archderm.131.3.292 · Paper page
  5. 10.1097/00004424-197903000-00002 · DOI · Paper page
  6. Goodenough DJ, 1974, Radiology, 110, 89, 10.1148/110.1.89 · DOI · Paper page
  7. 10.1016/0895-6111(94)90004-3 · DOI
  8. 10.1089/tmj.1.1996.2.131 · doi:10.1089/tmj.1.1996.2.131

Cited by

See all 33

Metadata

Authors
Vidmar, D. A., Cruess, D., Hsieh, P., Dolecek, Q., Pak, H., Gwynn, M., Maggio, K., Montemorano, A., Powers, J., Richards, D., Sperling, L., Wong, H., & Yeager, J.
Venue
Telemedicine Journal
Published
1999-12
Volume
5
Issue
4
Pages
375-383
ISSN
1078-3024 (ISSN-L)
OpenAlex
W2177251966
Cited by
33
References
1
FWCI
1.03
Type
journal article
Language
en
Open access
closed
Licence
www.liebertpub.com/nv/resources-tools/text-and-data-mining-policy/121/ (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Effect of Decreasing Digital Image Resolution on Teledermatology Diagnosis. https://app.cochat.ai/papers/10.1089/107830299311943
The paper
Vidmar, D. A., Cruess, D., Hsieh, P., Dolecek, Q., Pak, H., Gwynn, M., Maggio, K., Montemorano, A., Powers, J., Richards, D., Sperling, L., Wong, H., & Yeager, J. (1999). The Effect of Decreasing Digital Image Resolution on Teledermatology Diagnosis. Telemedicine Journal. https://doi.org/10.1089/107830299311943

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.