Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 699

The DOI matches its Crossref record.

ROC Analysis Applied to the Evaluation of Medical Imaging Techniques

SWETS, JOHN A.·1979·Investigative Radiology

Abstract

Analysis in terms of the relative operating characteristic (ROC) has recently been applied to several studies of medical decision-making, primarily to decisions based on imaging techniques. This paper presents a brief description of the ROC, and shows how it provides a measure of diagnostic accuracy that is free of judgmental bias. The results of medical studies are reviewed, and the main questions of theory and method that have arisen in the medical context are identified. Certain of these questions are basic to any psychophysical test, in which case an attempt has been made to present the best available answers. Other questions are of special medical importance and relevant reports are reviewed along with a description of current efforts to provide answers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004424-197903000-00002

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 699

Metadata

Authors
SWETS, J. A.
Venue
Investigative Radiology
Published
1979-03
Volume
14
Issue
2
Pages
109-121
ISSN
0020-9996 (ISSN-L)
OpenAlex
W2060136512
Cited by
699
References
0
FWCI
7.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ROC Analysis Applied to the Evaluation of Medical Imaging Techniques. https://app.cochat.ai/papers/10.1097/00004424-197903000-00002
The paper
SWETS, J. A. (1979). ROC Analysis Applied to the Evaluation of Medical Imaging Techniques. Investigative Radiology. https://doi.org/10.1097/00004424-197903000-00002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.