Continuous Glucose Monitoring with Glucose Sensors: Calibration and Assessment Criteria
The DOI matches its Crossref record.
Abstract
Continuous glucose monitoring (CM) by means of minimally invasive or noninvasive glucose sensors can help to further optimize metabolic control in patients with diabetes without need for frequent capillary blood glucose measurements. Most glucose sensors measure glucose concentration in the interstitial fluid (ISF). Because of the varying conditions in this compartment, a general in vitro calibration ( = factory calibration) by the manufacturer appears not to be possible. Therefore, calibration of the sensor signal must be performed by the patient himself repeatedly. The calibration procedure can be performed by means of conventional capillary blood glucose measurements in order to transform the sensor signals obtained from the specific compartment (e.g., ISF) into "blood" glucose values. A number of aspects can influence the validity of this procedure. The relationship between changes in blood glucose and in ISF glucose, in both time and concentration dimensions, is not well understood, especially during dynamic changes. The physical lag time, which critically depends on the glucose sensor technology used, can also introduce a systematic calibration error. After the first calibration, usually performed some hours after the application of a given glucose sensor, recalibration at certain intervals is necessary. Therefore, patients should critically assess the values displayed by a CM system. In the case of implausible glucose values they should verify the results by means of a conventional capillary glucose measurement. Up to now there is no consensus on assessment criteria to be used for evaluation of CM system performance and calibration quality. Existing methods of displaying CM values against corresponding reference values, including linear regression analysis and error grid analysis, as well as numeric criteria such as System Error, Predicted Error Sum of Squares (in %), and Mean Absolute Deviation are not generally applicable to CM. It appears as if they do not allow sufficient description of data obtained with CM systems. There is a pressing need to develop novel adequate assessment criteria enabling a better characterization of CM system performance. If these were used uniformly by all manufacturers and scientists assessing CM systems, this would allow a fair comparison of the performance of different systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285
Continuous Glucose Monitoring: Real-Time Algorithms for Calibration, Filtering, and Alarms
Bequette, B. W. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400222 · Cited by 192
“ ŷk = −a1 ŷk−1 −− aN ŷk− N + b0 yk + b1yk−1 ++ bM yk− M, (13)”
Limits to the Evaluation of the Accuracy of Continuous Glucose Monitoring Systems by Clinical Trials
Schrangl, P., Reiterer, F., Heinemann, L., Freckmann, G., & Del Re, L. (2018) · Biosensors · doi:10.3390/bios8020050 · Cited by 46
“This allows for a simple calibration procedure of the glucose sensor of the CGM system by using corresponding SMBG values [33,34].”
MethodSelf-citation
Metadata
- Authors
- Lodwig, V., & Heinemann, L.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2003-08
- Volume
- 5
- Issue
- 4
- Pages
- 572-586
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2095569161
- Cited by
- 63
- References
- 0
- FWCI
- 2.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.