CoChat

The Accuracy of the CGMS ™ in Children with Type 1 Diabetes: Results of the Diabetes Research in Children Network (DirecNet) Accuracy Study

Open access
· 2003 · Diabetes Technology & Therapeutics
Cited by 113

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The accuracy of the Continuous Glucose Monitoring System, CGMS (Medtronic MiniMed, Northridge, CA) was assessed in children and adolescents with type 1 diabetes mellitus (T1DM) when compared with reference serum glucose levels during spontaneous fluctuations in glucose levels over 24 h and during acute hyper- and hypoglycemia. Ninety-one subjects with type 1 diabetes (3.5-17.7 years old) wore one or two CGMSs while blood samples were obtained for serum glucose determinations (made at a central laboratory) hourly during the day, every 30 min overnight, and every 5 min during meal-induced hyperglycemia and insulin-induced hypoglycemia tests, resulting in 6778 CGMS-reference glucose pairs. CGMS function was assessed on each of the 3 days of sensor life. The median relative absolute difference (RAD) between the CGMS and reference values was 18% (25th, 75th percentiles = 8%, 34%). Similar results were obtained on each of the 3 days of sensor life. Accuracy was worse during hypoglycemia than during hyperglycemia. Modified sensors that first became available in November 2002 were more accurate than were the original sensors (median RAD = 11% vs. 19%) and had better precision (r = 0.92 vs. r = 0.77) during time periods in which two CGMSs were simultaneously used. The CGMS sensors that have been in clinical use until recently are often inaccurate in quantifying glucose values in children with T1DM. However, recent modifications to the sensor have resulted in substantially better accuracy and reliability. This improved function, if confirmed by additional data, may enhance the clinical utility of the CGMS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/152091503322526987

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 113

Metadata

Venue
Diabetes Technology & Therapeutics
Published
2003-10
Volume
5
Issue
5
Pages
781-789
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W4253301460
Cited by
113
References
3
FWCI
9.32
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Accuracy of the CGMS ™ in Children with Type 1 Diabetes: Results of the Diabetes Research in Children Network (DirecNet) Accuracy Study. https://app.cochat.ai/papers/10.1089/152091503322526987
The paper
The Accuracy of the CGMS ™ in Children with Type 1 Diabetes: Results of the Diabetes Research in Children Network (DirecNet) Accuracy Study. (2003). Diabetes Technology & Therapeutics. https://doi.org/10.1089/152091503322526987

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.