Artificial Pancreas: Past, Present, Future
Open accessAbstract
The artificial pancreas (AP), known as closed-loop control of blood glucose in diabetes, is a system combining a glucose sensor, a control algorithm, and an insulin infusion device. AP developments can be traced back 50 years to when the possibility for external blood glucose regulation was established by studies in individuals with type 1 diabetes using intravenous glucose measurement and infusion of insulin and glucose. After the pioneering work by Kadish (1) in 1964, expectations for effectively closing the loop were inspired by the nearly simultaneous work of five teams reporting closed-loop control results between 1974 and 1978: Albisser et al. (2), Pfeiffer et al. (3), Mirouze et al. (4), Kraegen et al. (5), and Shichiri et al. (6). In 1977, one of these realizations (3) resulted in the first commercial device—the Biostator (7; Fig. 1), followed by another inpatient system, the Nikkiso STG-22 Blood Glucose Controller, now in use in Japan (8). FIG. 1. The Biostator (courtesy of William Clarke, University of Virginia). Although the intravenous route of glucose sensing and insulin infusion is unsuitable for outpatient use, these devices proved the feasibility of external glucose control and stimulated further technology development. Figure 2 presents key milestones in the timeline of AP progress. FIG. 2. Key milestones in the timeline of AP progress. EU, Europe; IP, intraperitoneal; NIH, National Institutes of Health; SC, subcutaneous. In 1979, landmark studies by Pickup et al. (9) and Tamborlane et al. (10) showed that the subcutaneous route was feasible for continuous insulin delivery. Three years later, Shichiri et al. (11) tested a prototype of a wearable AP, which was further developed in subsequent studies (12,13). In the late 1980s, an implantable system was introduced using intravenous glucose sensing and intraperitoneal insulin infusion (14). This technology was further developed, leading to clinical trials and …
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The development of artificial pancreas control algorithms in the past few years has been accelerated by computer simulation.
“The development of artificial pancreas control algorithms in the past few years has been accelerated by computer simulation; for example, in silico testing has provided directions for clinical studies and ruling out of ineffective control scenarios in a cost-effective manner. 1,2”
From The UVA/PADOVA Type 1 Diabetes Simulator: New Features (2014) · cites this paper as [2]
In “A step forward: in silico experiments replacing animal trials” (page unavailable), the paper says simulation is already used to test control algorithms efficiently and at a fraction of the time and cost of animal trials. But it says simulation *will* greatly accelerate future artificial-pancreas development; it does not establish that algorithm development had already accelerated in the past few years. (LLM, conf=0.85)
Experimental — accuracy not yet measuredIn silico testing has provided directions for clinical studies and ruling out of ineffective control scenarios in a cost-effective manner.
“in silico testing has provided directions for clinical studies and ruling out of ineffective control scenarios in a cost-effective manner. 1,2”
From The UVA/PADOVA Type 1 Diabetes Simulator: New Features (2014) · cites this paper as [2]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
HEPATOCELLULAR CARCINOMA AND HEPATITIS B VIRUS
Beasley, R. P., Lin, C., Hwang, L., & Chien, C. (1981) · The Lancet · doi:10.1016/s0140-6736(81)90585-7 · Cited by 2,856 · see citing works
Quantitative estimation of insulin sensitivity.
Bergman, R. N., Ider, Y. Z., Bowden, C. R., & Cobelli, C. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.236.6.e667 · Cited by 1,874 · see citing works
Self-citationContinuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559 · see citing works
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274 · see citing works
Meal Simulation Model of the Glucose-Insulin System
Dalla Man, C., Rizza, R. A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893506 · Cited by 955 · see citing works
Self-citation<i>In Silico</i> Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760 · see citing works
Self-citationKlonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 725 · see citing works
WEINZIMER, S. A., Steil, G. M., Swan, K. L., Dziura, J., Kurtz, N., & Tamborlane, W. V. (2008) · Diabetes Care · doi:10.2337/dc07-1967 · Cited by 567 · see citing works
Continuous subcutaneous insulin infusion: an approach to achieving normoglycaemia.
Pickup, J. C., KEEN, H., PARSONS, J. A., & Alberti, K. G. M. M. (1978) · BMJ · doi:10.1136/bmj.1.6107.204 · Cited by 563 · see citing works
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539 · see citing works
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511 · see citing works
Self-citationA model-based algorithm for blood glucose control in Type I diabetic patients
Parker, R. S., Doyle, F., & Peppas, N. A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.740877 · Cited by 500 · see citing works
Feasibility of Automating Insulin Delivery for the Treatment of Type 1 Diabetes
Steil, G. M., Rebrin, K., Darwin, C. H., Hariri, F., & Saad, M. F. (2006) · Diabetes · doi:10.2337/db06-0419 · Cited by 473 · see citing works
[Lys(B28), Pro(B29)]-Human Insulin: A Rapidly Absorbed Analogue of Human Insulin
Howey, D. C., Bowsher, R. R., Brunelle, R. L., & Woodworth, J. R. (1994) · Diabetes · doi:10.2337/diab.43.3.396 · Cited by 471 · see citing works
Hovorka, R., Allen, J. M., Elleri, D., Chassin, L. J., Harris, J. R., Xing, D., Kollman, C., Hovorka, T., Larsen, A. M. F., Nodale, M., et al. (2010) · The Lancet · doi:10.1016/s0140-6736(09)61998-x · Cited by 448 · see citing works
Continuous glucose monitoring and closed‐loop systems
Hovorka, R. (2005) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 440 · see citing works
Improvement in Glycemic Excursions With a Transcutaneous, Real-Time Continuous Glucose Sensor
Garg, S. K., Zisser, H., Schwartz, S. L., Bailey, T. S., Kaplan, R. A., Ellis, S. L., & Jovanovič, L. (2006) · Diabetes Care · doi:10.2337/diacare.29.01.06.dc05-1686 · Cited by 429 · see citing works
Tamborlane, W. V., Sherwin, R. S., Genel, M., & Felig, P. (1979) · New England Journal of Medicine · doi:10.1056/nejm197903153001101 · Cited by 411 · see citing works
Boyne, M. S., Silver, D. M., Kaplan, J., & Saudek, C. D. (2003) · Diabetes · doi:10.2337/diabetes.52.11.2790 · Cited by 404 · see citing works
A physiological model of glucose-insulin interaction in type 1 diabetes mellitus
Lehmann, E. D., & Deutsch, T. (1992) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(92)90058-s · Cited by 403 · see citing works
A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
El-Khatib, F. H., Russell, S. J., Nathan, D. M., Sutherlin, R. G., & Damiano, E. R. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000619 · Cited by 403 · see citing works
Continuous Subcutaneous Insulin Infusion at 25 Years
Pickup, J. C., & KEEN, H. (2002) · Diabetes Care · doi:10.2337/diacare.25.3.593 · Cited by 397 · see citing works
The MiniMed Continuous Glucose Monitoring System
Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050214078 · Cited by 393 · see citing works
An Artificial Endocrine Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W. (1974) · Diabetes · doi:10.2337/diab.23.5.389 · Cited by 379 · see citing works
Rebrin, K., Steil, G. M., van Antwerp, W. P., & Mastrototaro, J. J. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.277.3.e561 · Cited by 367 · see citing works
Model Predictive Control of Type 1 Diabetes: An <i>in Silico</i> Trial
Magni, L., Raimondo, D. M., Bossi, L., Dalla Man, C., De Nicolao, G., Kovatchev, B., & Cobelli, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100603 · Cited by 317 · see citing works
Self-citationWEARABLE ARTIFICIAL ENDOCRINE PANCREAS WITH NEEDLE-TYPE GLUCOSE SENSOR
Shichiri, M., Yamasaki, Y., Kawamori, R., Hakui, N., & Abe, H. (1982) · The Lancet · doi:10.1016/s0140-6736(82)92788-x · Cited by 314 · see citing works
Closed-loop insulin delivery—the path to physiological glucose control
Steil, G. M. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.011 · Cited by 310 · see citing works
Bequette, B. W. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.28 · Cited by 271 · see citing works
GIM, Simulation Software of Meal Glucose–Insulin Model
Dalla Man, C., Raimondo, D. M., Rizza, R. A., & Cobelli, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100303 · Cited by 253 · see citing works
Self-citationPhysiological Differences Between Interstitial Glucose and Blood Glucose Measured in Human Subjects
Kulcu, E., Tamada, J. A., Reach, G., Potts, R. O., & Lesho, M. J. (2003) · Diabetes Care · doi:10.2337/diacare.26.8.2405 · Cited by 252 · see citing works
Hovorka, R., Kumareswaran, K., Harris, J., Allen, J. M., Elleri, D., Xing, D., Kollman, C., Nodale, M., Murphy, H. R., Dunger, D. B., et al. (2011) · BMJ · doi:10.1136/bmj.d1855 · Cited by 244 · see citing works
Pfeiffer, E. F., Thum, C., & Clemens, A. (1974) · Hormone and Metabolic Research · doi:10.1055/s-0028-1093841 · Cited by 238 · see citing works
Comparison of the Numerical and Clinical Accuracy of Four Continuous Glucose Monitors
Kovatchev, B. P., Anderson, S. M., Heinemann, L., & Clarke, W. L. (2008) · Diabetes Care · doi:10.2337/dc07-2401 · Cited by 236 · see citing works
Self-citationThe intravenous route to blood glucose control
Parker, R. S., Doyle, F., & Peppas, N. A. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.897829 · Cited by 235 · see citing works
Novel Use of Glucagon in a Closed-Loop System for Prevention of Hypoglycemia in Type 1 Diabetes
Castle, J. R., Engle, J. M., Youssef, J. E., Massoud, R. G., Yuen, K. C. J., Kagan, R., & Ward, W. K. (2010) · Diabetes Care · doi:10.2337/dc09-2254 · Cited by 232 · see citing works
Can Interstitial Glucose Assessment Replace Blood Glucose Measurements?
Rebrin, K., & Steil, G. M. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050194332 · Cited by 220 · see citing works
Zone Model Predictive Control: A Strategy to Minimize Hyper- and Hypoglycemic Events
Grosman, B., Dassau, E., Zisser, H., Jovanovic, L. G., & Doyle, F. J. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400428 · Cited by 204 · see citing works
Kovatchev, B., Cobelli, C., Renard, E., Anderson, S., Breton, M., Patek, S., Clarke, W., Bruttomesso, D., Maran, A., Costa, S., et al. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400611 · Cited by 200 · see citing works
Self-citationBode, B. W., Gross, K. M., Rikalo, N., Schwartz, S. L., Wahl, T. O., Page, C. W., Gross, T. M., & Mastrototaro, J. J. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504773731285 · Cited by 190 · see citing works
The development of Biostator, a Glucose Controlled Insulin Infusion System (GCIIS).
Clemens, A. H., Chang, P. H., & Myers, R. W. (1977) · PubMed · Cited by 190 · see citing works
Aussedat, B., Dupire-Angel, M., Gifford, R., Klein, J. C., Wilson, G. S., & Reach, G. (2000) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2000.278.4.e716 · Cited by 186 · see citing works
Feldman, B., Brazg, R., Schwartz, S. L., & Weinstein, R. L. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322526978 · Cited by 184 · see citing works
Renard, É., Place, J., Cantwell, M., Chevassus, H., & Palerm, C. C. (2009) · Diabetes Care · doi:10.2337/dc09-1080 · Cited by 176 · see citing works
Implantable closed-loop glucose-sensing and insulin delivery: the future for insulin pump therapy
Renard, É. (2002) · Current Opinion in Pharmacology · doi:10.1016/s1471-4892(02)00216-3 · Cited by 151 · see citing works
Interstitial fluid glucose dynamics during insulin-induced hypoglycaemia
Steil, G. M., Rebrin, K., Hariri, F., Jinagonda, S., Tadros, S. S., Darwin, C. H., & Saad, M. F. (2005) · Diabetologia · doi:10.1007/s00125-005-1852-x · Cited by 148 · see citing works
Cobelli, C., & Mari, A. (1983) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442625 · Cited by 140 · see citing works
Self-citationThe subcutaneous route to insulin dependent diabetes therapy
Bellazzi, R., Nucci, G., & Cobelli, C. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.897828 · Cited by 139 · see citing works
Self-citationMelki, V., Renard, É., Lassmann-Vague, V., Boivin, S., Guerci, B., Hanaire, H. P., Bringer, J., Bélicar, P., Jeandidier, N., Meyer, L., et al. (1998) · Diabetes Care · doi:10.2337/diacare.21.6.977 · Cited by 137 · see citing works
Hirsch, I. B., Armstrong, D. U., Bergenstal, R. M., Buckingham, B. A., Childs, B. P., Clarke, W. L., Peters, A. L., & Wolpert, H. A. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0016 · Cited by 136 · see citing works
Andreassen, S., Benn, J. J., Hovorka, R., Olesen, K. G., & Carson, E. R. (1994) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(94)90052-3 · Cited by 135 · see citing works
Preventing Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension
Buckingham, B. A., Cobry, E. C., Clinton, P. K., Gage, V., Caswell, K., Kunselman, E. L., Cameron, F., & Chase, H. P. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0032 · Cited by 132 · see citing works
A Preliminary Trial of the Programmable Implantable Medication System for Insulin Delivery
Saudek, C. D., Sélam, J.-L., Pitt, H. A., et al. (1989) · New England Journal of Medicine · doi:10.1056/nejm198908313210904 · Cited by 130 · see citing works
Run-to-run control of blood glucose concentrations for people with type 1 diabetes mellitus
Owens, C., Zisser, H., Jovanovič, L., Srinivasan, B., Bonvin, D., & Doyle, F. J. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.872818 · Cited by 122 · see citing works
Evaluation of Factors Affecting CGMS Calibration
Diabetes Research In Children Network (Direcnet) Study Group (2006) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.8.318 · Cited by 116 · see citing works
A run-to-run control strategy to adjust basal insulin infusion rates in type 1 diabetes
Palerm, C. C., Zisser, H., Jovanovic, L. G., & Doyle, F. J. (2007) · Journal of Process Control · doi:10.1016/j.jprocont.2007.07.010 · Cited by 113 · see citing works
(2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322526987 · Cited by 113 · see citing works
Run-to-Run Tuning of Model Predictive Control for Type 1 Diabetes Subjects: In Silico Trial
Magni, L., Forgione, M., Toffanin, C., Man, C. D., Kovatchev, B. P., Nicolao, G. D., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300512 · Cited by 106 · see citing works
Self-citationPoscia, A., Mascini, M., Moscone, D., Luzzana, M., Caramenti, G., Cremonesi, P., Valgimigli, F., Bongiovanni, C., & Varalli, M. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00216-6 · Cited by 101 · see citing works
Kinetic Modeling of the Glucoregulatory System to Improve Insulin Therapy
Salzsieder, E., Albrecht, G., Fischer, U., & Freyse, E. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325500 · Cited by 101 · see citing works
Physiologic insulin delivery with insulin feedback: A control systems perspective
Palerm, C. C. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2010.06.007 · Cited by 97 · see citing works
The Extended Kalman Filter for Continuous Glucose Monitoring
Knobbe, E. J., & Buckingham, B. A. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.15 · Cited by 95 · see citing works
Hypoglycemia Prediction and Detection Using Optimal Estimation
Palerm, C. C., Willis, J. P., Desemone, J., & Bequette, B. W. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.3 · Cited by 94 · see citing works
AUTOMATION CONTROL OF BLOOD SUGAR. I. A SERVOMECHANISM FOR GLUCOSE MONITORING AND CONTROL.
Kadish, A. H. (1964) · PubMed · Cited by 94 · see citing works
Garg, S. K., Smith, J. G. W., Beatson, C. R., Lopez-Baca, B., Voelmle, M. K., & Gottlieb, P. A. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0109 · Cited by 93 · see citing works
Devices for Insulin Administration
Sélam, J.-L., & Charles, M. A. (1990) · Diabetes Care · doi:10.2337/diacare.13.9.955 · Cited by 91 · see citing works
Clinical Trial of Programmable Implantable Insulin Pump For Type I Diabetes
Sélam, J.-L., Micossi, P., Dunn, F. L., Nathan, D. M., & Implantable Insulin Pump Trial Study Group (1992) · Diabetes Care · doi:10.2337/diacare.15.7.877 · Cited by 90 · see citing works
Hughes, C. S., Patek, S. D., Breton, M. D., & Kovatchev, B. P. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400513 · Cited by 89 · see citing works
Self-citationFrench multicentre experience of implantable insulin pumps
Broussolle, C. (1994) · The Lancet · doi:10.1016/s0140-6736(94)91462-1 · Cited by 87 · see citing works
Mirouze, J., Selam, J. L., Pham, T. C., & Cavadore, D. (1977) · Diabetologia · doi:10.1007/bf01219712 · Cited by 86 · see citing works
The Artificial Pancreas: How Sweet Engineering Will Solve Bitter Problems
Klonoff, D. C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100112 · Cited by 84 · see citing works
Hanaire, H. P., Broussolle, C., Jeandidier, N., et al. (1995) · Diabetes Care · doi:10.2337/diacare.18.3.388 · Cited by 83 · see citing works
Control to Range for Diabetes: Functionality and Modular Architecture
Kovatchev, B. P., Patek, S. D., Dassau, E., Doyle, F. J., Magni, L., Nicolao, G. D., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300509 · Cited by 83 · see citing works
Self-citationCobelli, C., & Ruggeri, A. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325203 · Cited by 82 · see citing works
Self-citationHashiguchi, Y., Sakakida, M., Nishida, K., Uemura, T., Kajiwara, K., & Shichiri, M. (1994) · Diabetes Care · doi:10.2337/diacare.17.5.387 · Cited by 82 · see citing works
Modular Artificial β-Cell System: A Prototype for Clinical Research
Dassau, E., Zisser, H., Palerm, C. C., Buckingham, B. A., Jovanovic, L. G., & Doyle, F. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200518 · Cited by 80 · see citing works
Artificial β-cell: clinical experience toward an implantable closed-loop insulin delivery system
Renard, É., Costalat, G., Chevassus, H., & Bringer, J. (2006) · Diabetes & Metabolism · doi:10.1016/s1262-3636(06)72802-6 · Cited by 78 · see citing works
Run-to-Run Control of Meal-Related Insulin Dosing
Zisser, H., Jovanovič, L., Doyle, F., Ospina, P., & Owens, C. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.48 · Cited by 78 · see citing works
Yatabe, T., Yamazaki, R., Kitagawa, H., Okabayashi, T., Yamashita, K., Hanazaki, K., & Yokoyama, M. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e318206b9ad · Cited by 73 · see citing works
Continuous Glucose Sensors: Continuing Questions about Clinical Accuracy
Clarke, W. L., & Kovatchev, B. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100510 · Cited by 71 · see citing works
Self-citationEnhanced Accuracy of Continuous Glucose Monitoring by Online Extended Kalman Filtering
Facchinetti, A., Sparacino, G., & Cobelli, C. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0158 · Cited by 70 · see citing works
Self-citationFacchinetti, A., Sparacino, G., & Cobelli, C. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400102 · Cited by 67 · see citing works
Self-citationShichiri, M., Sakakida, M., Nishida, K., & Shimoda, S. (1998) · Artificial Organs · doi:10.1046/j.1525-1594.1998.06043.x · Cited by 66 · see citing works
Srinivasan, R., Kadish, A. H., & Sridhar, R. (1970) · Computers and Biomedical Research · doi:10.1016/0010-4809(70)90021-2 · Cited by 65 · see citing works
King, C., Anderson, S. M., Breton, M. D., Clarke, W. L., & Kovatchev, B. P. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100302 · Cited by 65 · see citing works
Self-citationClinical Utility of the Continuous Glucose Monitoring System
Bode, B. W. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050214104 · Cited by 64 · see citing works
Shishko, P. I., Kovalev, P. A., Goncharov, V. G., & Zajarny, I. U. (1992) · Diabetes · doi:10.2337/diab.41.9.1042 · Cited by 63 · see citing works
Botz, C. K., LEIBEL, B. S., Zingg, W., et al. (1976) · Diabetes · doi:10.2337/diab.25.8.691 · Cited by 63 · see citing works
An Online Self-Tunable Method to Denoise CGM Sensor Data
Facchinetti, A., Sparacino, G., & Cobelli, C. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2033264 · Cited by 62 · see citing works
Self-citationComparison of Algorithms for the Closed-Loop Control of Blood Glucose Using the Artificial Beta Cell
Broekhuyse, H. M., Nelson, H. D., Zinman, B., & Albisser, A. M. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324661 · Cited by 61 · see citing works
McGarraugh, G. V., & Bergenstal, R. M. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0047 · Cited by 61 · see citing works
Stout, P. J., Racchini, J. R., & Hilgers, M. E. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.635 · Cited by 59 · see citing works
Guerci, B., Meyer, L., Sallé, A., Charrié, A., Dousset, B., Ziegler, O., & Drouin, P. (1999) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.84.8.5912 · Cited by 58 · see citing works
A Dual-Rate Kalman Filter for Continuous Glucose Monitoring
Kuure-Kinsey, M., Palerm, C. C., & Bequette, B. W. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260057 · Cited by 58 · see citing works
Control of Blood Glucose in Diabetics using an Artificial Pancreas*
Kraegen, E. W., Campbell, L. V., Chia, Y. O., Meier, H., & Lazarus, L. (1977) · Australian and New Zealand Journal of Medicine · doi:10.1111/j.1445-5994.1977.tb03687.x · Cited by 57 · see citing works
The Accuracy of the Guardian ® RT Continuous Glucose Monitor in Children with Type 1 Diabetes
The Diabetes Research in Children Network (DirecNet) Study Group (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0279 · Cited by 56 · see citing works
LYS(B28)PRO(B29)-HUMAN INSULIN
Ciszak, E. M., Beals, J. M., Frank, B., et al. (1995) · Worldwide Protein Data Bank · doi:10.2210/pdb1lph/pdb · Cited by 55 · see citing works
Wentholt, I. M. E., Hart, A. A. M., Hoekstra, J. B. L., & DeVries, J. H. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.0007 · Cited by 54 · see citing works
Kovatchev, B. P., & Clarke, W. L. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200125 · Cited by 54 · see citing works
Self-citationNathan, D. M., Dunn, F. L., Bruch, J. S., McKitrick, C., Larkin, M., Haggan, C., Lavin-Tompkins, J. M., Norman, D., Rogers, D., & Simon, D. A. (1996) · The American Journal of Medicine · doi:10.1016/s0002-9343(97)89516-2 · Cited by 53 · see citing works
Peritoneal and subcutaneous absorption of insulin in type I diabetic subjects
Giacca, A., Caumo, A., Galimberti, G. A., Petrella, G., Librenti, M. C., Scavini, M., Pozza, G., & Micossi, P. (1993) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.77.3.8370695 · Cited by 52 · see citing works
Chase, J. G., Hann, C. E., Jackson, M. I., Lin, J., Lotz, T., Wong, X., & Shaw, G. M. (2006) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2006.03.004 · Cited by 49 · see citing works
Nelson, J. A., Stephen, R. L., Landau, S. T., Wilson, D. E., & Tyler, F. H. (1982) · Metabolism · doi:10.1016/0026-0495(82)90136-6 · Cited by 49 · see citing works
Renard, É., Bouteleau, S., Jacques-Apostol, D., et al. (1996) · Diabetes Care · doi:10.2337/diacare.19.8.812 · Cited by 45 · see citing works
Olsen, C. L., Chan, E. K., Turner, D. S., et al. (1994) · Diabetes Care · doi:10.2337/diacare.17.3.169 · Cited by 43 · see citing works
Renard, E., Guerci, B., Leguerrier, A.-M., & Boizel, R. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0073 · Cited by 42 · see citing works
Self-citationOskarsson, P., Lins, P. E., Bäckman, L., et al. (2000) · PubMed · Cited by 42 · see citing works
OmniPod Insulin Management System
Zisser, H., & Jovanovič, L. (2006) · Diabetes Care · doi:10.2337/dc06-0986 · Cited by 38 · see citing works
Catargi, B., Meyer, L., Melki, V., et al. (2002) · PubMed · Cited by 38 · see citing works
Guerci, B. (1999) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.84.8.2673 · Cited by 34 · see citing works
Hughes, C. S., Patek, S. D., Breton, M. D., & Kovatchev, B. P. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2010.04.011 · Cited by 33 · see citing works
Self-citationNoujaim, S. E., Horwitz, D. L., Sharma, M., & Marhoul, J. C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100509 · Cited by 29 · see citing works
Juvenile Diabetes Research Foundation Artificial Pancreas Consortium Update
Kowalski, A. J., & Lum, J. W. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300531 · Cited by 28 · see citing works
A Simulation Study on a Self-Tuning Portable Controller of Blood Glucose
Brunetti, P., Cobelli, C., Cruciani, P., et al. (1993) · The International Journal of Artificial Organs · doi:10.1177/039139889301600111 · Cited by 26 · see citing works
Self-citationBlackshear, P. J., Shulman, G. I., Roussell, A. M., Nathan, D. M., Minaker, K. L., Rowe, J. W., Robbins, D. C., & Cohen, A. M. (1985) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-61-4-753 · Cited by 25 · see citing works
Glycemic Control with Closed-Loop Intraperitoneal Insulin in Type I Diabetes
Leblanc, H., Chauvet, D., Lombrail, P., & Robert, J. J. (1986) · Diabetes Care · doi:10.2337/diacare.9.2.124 · Cited by 23 · see citing works
Oskarsson, P., Lins, P. E., Henriksson, H., et al. (1999) · PubMed · Cited by 23 · see citing works
Hypoglycemia Warning Signal and Glucose Sensors: Requirements and Concepts
Heise, T., Koschinsky, T., Heinemann, L., & Lodwig, V. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322250587 · Cited by 22 · see citing works
Quality Control of Self-Monitoring of Blood Glucose: Why and How?
Solnica, B., & Naskalski, J. W. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100204 · Cited by 19 · see citing works
Pharmacokinetics of insulin infused intra-peritoneally via portable pumps.
Jl, S., Raymond, M., Jl, J., et al. (1985) · PubMed · Cited by 19 · see citing works
Analysis:The Role of New Technology in the Early Detection of Hypoglycemia
Ward, W. K. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504773731294 · Cited by 14 · see citing works
Cobelli, C., & Ruggeri, A. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442404 · Cited by 11 · see citing works
Self-citationRenard, É., Bruttomesso, D., Magni, L., et al. (2011) · Cited by 2 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- [119]Micheletto F, Dalla Man C, Vella A, Cobelli C. A model of glucagon secretion and action in healthy subjects. Proceedings of the 10th Diabetes Technology Meeting, Bethesda, MD, 2010, A105
Cited by
Sorted by citations
Atkinson, M. A., Eisenbarth, G. S., & Michels, A. W. (2014) · The Lancet · doi:10.1016/s0140-6736(13)60591-7 · Cited by 2,713 · see citing works
The UVA/PADOVA Type 1 Diabetes Simulator: New Features
Man, C. D., Micheletto, F., Lv, D., Breton, M., Kovatchev, B., & Cobelli, C. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813514502 · Cited by 791 · see citing works
Self-citationFully Integrated Artificial Pancreas in Type 1 Diabetes
Breton, M., Farret, A., Bruttomesso, D., Anderson, S., Magni, L., Patek, S., Dalla Man, C., Place, J., Demartini, S., Del Favero, S., et al. (2012) · Diabetes · doi:10.2337/db11-1445 · Cited by 315 · see citing works
Self-citationArtificial intelligence in diabetes management: Advancements, opportunities, and challenges
Guan, Z., Li, H., Liu, R., Cai, C., Liu, Y., Li, J., Wang, X., Huang, S., Wu, L., Liu, D., et al. (2023) · Cell Reports Medicine · doi:10.1016/j.xcrm.2023.101213 · Cited by 287 · see citing works
A review of personalized blood glucose prediction strategies for T1DM patients
Oviedo, S., Vehí, J., Calm, R., & Armengol, J. (2017) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2833 · Cited by 279 · see citing works
Assessing Sensor Accuracy for Non-Adjunct Use of Continuous Glucose Monitoring
Kovatchev, B. P., Patek, S. D., Ortiz, E. A., & Breton, M. D. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0272 · Cited by 234 · see citing works
Self-citationModeling the glucose sensor error
Facchinetti, A., Del Favero, S., Sparacino, G., Castle, J. R., Ward, W. K., & Cobelli, C. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2284023 · Cited by 130 · see citing works
Breton, M. D., Brown, S. A., Karvetski, C. H., Kollar, L., Topchyan, K. A., Anderson, S. M., & Kovatchev, B. P. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0333 · Cited by 128 · see citing works
Self-citationMultinational Home Use of Closed-Loop Control Is Safe and Effective
Anderson, S. M., Raghinaru, D., Pinsker, J. E., Boscari, F., Renard, E., Buckingham, B. A., Nimri, R., Doyle, F. J., Brown, S. A., Keith-Hynes, P., et al. (2016) · Diabetes Care · doi:10.2337/dc15-2468 · Cited by 120 · see citing works
Self-citationCircadian Variability of Insulin Sensitivity: Physiological Input for In Silico Artificial Pancreas
Visentin, R., Dalla Man, C., Kudva, Y. C., Basu, A., & Cobelli, C. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0192 · Cited by 113 · see citing works
Self-citationRenard, E., Farret, A., Kropff, J., Bruttomesso, D., Messori, M., Place, J., Visentin, R., Calore, R., Toffanin, C., Di Palma, F., et al. (2016) · Diabetes Care · doi:10.2337/dc16-0008 · Cited by 104 · see citing works
Self-citationFirst use of model predictive control in outpatient wearable artificial pancreas
Del Favero, S., Bruttomesso, D., Di Palma, F., Lanzola, G., Visentin, R., Filippi, A., Scotton, R., Toffanin, C., Messori, M., Scarpellini, S., et al. (2014) · Diabetes Care · doi:10.2337/dc13-1631 · Cited by 103 · see citing works
Self-citationThe Artificial Pancreas in 2016: A Digital Treatment Ecosystem for Diabetes
Kovatchev, B., Tamborlane, W. V., Cefalu, W. T., & Cobelli, C. (2016) · Diabetes Care · doi:10.2337/dc16-0824 · Cited by 95 · see citing works
Self-citationManohar, C., Levine, J. A., Nandy, D. K., Saad, A., Dalla Man, C., McCrady-Spitzer, S. K., Basu, R., Cobelli, C., Carter, R. E., Basu, A., et al. (2012) · Diabetes Care · doi:10.2337/dc11-2381 · Cited by 89 · see citing works
Self-citationFacchinetti, A., Del Favero, S., Sparacino, G., & Cobelli, C. (2015) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-014-1226-y · Cited by 80 · see citing works
Self-citationPsychosocial impact of the bionic pancreas during summer camp
Weissberg-Benchell, J., Hessler, D., Polonsky, W. H., & Fisher, L. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816640289 · Cited by 47 · see citing works
Advancing Our Understanding of the Glucose System via Modeling: A Perspective
Cobelli, C., Dalla Man, C., Pedersen, M. G., Bertoldo, A., & Toffolo, G. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2310514 · Cited by 46 · see citing works
Self-citationA comparison among three maximal mathematical models of the glucose-insulin system
Pompa, M., Panunzi, S., Borri, A., & De Gaetano, A. (2021) · PLOS ONE · doi:10.1371/journal.pone.0257789 · Cited by 24 · see citing works
Panunzi, S., Pompa, M., Borri, A., Piemonte, V., & De Gaetano, A. (2020) · PLoS ONE · doi:10.1371/journal.pone.0237215 · Cited by 21 · see citing works
Modeling Glucagon Action in Patients With Type 1 Diabetes
Emami, A., Youssef, J. E., Rabasa-Lhoret, R., Pineau, J., Castle, J. R., & Haidar, A. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2593630 · Cited by 20 · see citing works
Schiavon, M., Galderisi, A., Basu, A., Kudva, Y. C., Cengiz, E., & Dalla Man, C. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0397 · Cited by 8 · see citing works
Robustness evaluation of computer-aided clinical trials for medical devices
Jang, K. J., Pant, Y. V., Zhang, B., Weimer, J., & Mangharam, R. (2019) · Proceedings of the 10th ACM/IEEE International Conference on Cyber-Physical Systems · doi:10.1145/3302509.3311058 · Cited by 6 · see citing works
- Authors
- Cobelli, C., Renard, E., & Kovatchev, B.
- Affiliations
- University of Padua (IT)
- Department of Endocrinology, Diabetes, Nutrition, Montpellier University Hospital, Montpellier, France
- University of Virginia (US)
- Corresponding author
- Cobelli, Claudio
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 2011-10-17
- Volume
- 60
- Issue
- 11
- Pages
- 2672-2682
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- PMC
- PMC3198099
- OpenAlex
- W2162557622
- Cited by
- 600
- References
- 123
- Citations by year
- 2026: 23 · 2025: 31 · 2024: 37 · 2023: 28 · 2022: 32 · 2021: 29 · 2020: 45 · 2019: 47 · 2018: 56 · 2017: 58 · 2016: 34 · 2015: 50 · 2014: 57 · 2013: 43 · 2012: 29
- FWCI
- 5.73
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Diabetes (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Funders
- Juvenile Diabetes Research Foundation International
- Ministero dell'Università e della Ricerca
- National Institutes of Health
- University of California, Santa Barbara
- U.S. Public Health Service (R01 085623)
- National Institute of Diabetes and Digestive and Kidney Diseases (R01DK085623)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- artificial pancreas, closed-loop glucose control, type 1 diabetes, insulin infusion, continuous glucose monitoring, subcutaneous insulin administration, intraperitoneal insulin infusion, Biostator
- MeSH terms
- Animals, Blood Chemical Analysis, Blood Glucose, Computer Simulation, Diabetes Mellitus, Type 1, Humans, Insulin, Insulin Infusion Systems, Pancreas, Artificial
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review