Determination of Plasma Glucose During Rapid Glucose Excursions with a Subcutaneous Glucose Sensor
The DOI matches its Crossref record.
Abstract
Continuous glucose monitoring has the potential to improve glucose management and reduce the risk of hypoglycemia in individuals with diabetes. Accurate sensors may also allow the development of a closed-loop insulin delivery system. The purpose of this work was to determine the delay time associated with a subcutaneous glucose sensor during rapidly changing glucose excursions. Subcutaneous glucose sensors (Medtronic MiniMed, Inc., Northridge, CA) were inserted in five healthy men. After a 2-h stabilization period, a 3-h hyperglycemic (approximately 11 mM) clamp was performed followed by a 90-min period in which plasma glucose was allowed to decline to as low as 2.8 mM. Sensors were calibrated using two points (basal and hyperglycemia), and the calibrated sensor glucose measurements were compared with those from a reference analyzer (Beckman Instruments, Fullerton, CA). Response time was estimated from a first-order kinetic model. Plasma glucose levels, determined with the subcutaneous sensor, were highly correlated with those obtained with the reference glucose analyzer (r(2) = 0.91, p < 0.001; mean absolute difference of approximately 8%). The half-time for the sensor response was estimated to be 4.0 +/- 1.0 min. The subcutaneous glucose sensor has the potential to facilitate the detection of hypoglycemia and improve overall glycemic control when used in a real-time monitor. The rapid response should be sufficient to allow a fully automated closed-loop insulin delivery system to be developed based on the subcutaneous sensing site.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
“This approach has been complicated by the fact hat the ratio of blood/tissue glucose is not constant, but deends on a number of factors related to physiology of glucose nd insulin (Steil et al., 2003; Aussedat et al., 2000).”
BackgroundProspects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
Yadav, J., Rani, A., Singh, V., & Murari, B. M. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.01.005 · Cited by 374
Closed-loop insulin delivery—the path to physiological glucose control
Steil, G. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.011 · Cited by 313
Self-citationAccuracy of the 5-Day FreeStyle Navigator Continuous Glucose Monitoring System
Weinstein, R. L., Schwartz, S. L., Brazg, R. L., Bugler, J. R., Peyser, T. A., & McGarraugh, G. V. (2007) · Diabetes Care · doi:10.2337/dc06-1602 · Cited by 228
“6 min, consistent with previously published studies using multicompartment diffusion models (13,20,21).”
Real-Time Continuous Glucose Monitoring in Critically Ill Patients
Holzinger, U., Warszawska, J., Kitzberger, R., Wewalka, M., Miehsler, W., Herkner, H., & Madl, C. (2010) · Diabetes Care · doi:10.2337/dc09-1352 · Cited by 212
Metadata
- Authors
- Steil, G. M., Rebrin, K., Mastrototaro, J., Bernaba, B., & Saad, M. F.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2003-02
- Volume
- 5
- Issue
- 1
- Pages
- 27-31
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W1966352630
- Cited by
- 104
- References
- 0
- FWCI
- 4.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of Plasma Glucose During Rapid Glucose Excursions with a Subcutaneous Glucose Sensor. https://app.cochat.ai/papers/10.1089/152091503763816436
- The paper
- Steil, G. M., Rebrin, K., Mastrototaro, J., Bernaba, B., & Saad, M. F. (2003). Determination of Plasma Glucose During Rapid Glucose Excursions with a Subcutaneous Glucose Sensor. Diabetes Technology & Therapeutics. https://doi.org/10.1089/152091503763816436
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.