A High Throughput Luminescent Assay for Glycogen Synthase Kinase-3 β Inhibitors
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A high throughput luminescent assay based on the Kinase-Glo() system (Promega, Madison, WI) has been developed for screening against glycogen synthase kinase-3beta (GSK-3beta). Careful optimization of assay parameters allowed us to develop a robust, reproducible, and sensitive assay. Its usefulness has been demonstrated in a high throughput screening run when screening 55,000 compounds. This campaign yielded five chemical classes of hits, including several highly potent GSK-3beta inhibitors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, J.-H., Chung, T. D. Y., & Oldenburg, K. R. (1999) · SLAS Discovery · doi:10.1177/108705719900400206 · Cited by 6,847
Cited by
ADP-Glo: A Bioluminescent and Homogeneous ADP Monitoring Assay for Kinases
Zegzouti, H., Zdanovskaia, M., Hsiao, K., & Goueli, S. A. (2009) · ASSAY and Drug Development Technologies · doi:10.1089/adt.2009.0222 · Cited by 273
Multitarget drug discovery for Alzheimer's disease: triazinones as BACE-1 and GSK-3β inhibitors
Prati, F., De Simone, A., Bisignano, P., Armirotti, A., Summa, M., Pizzirani, D., Scarpelli, R., Perez, D. I., Andrisano, V., Perez‐Castillo, A., et al. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201410456 · Cited by 128
Jiang, X.-Y., Chen, T.-K., Zhou, J.-T., He, S.-Y., Yang, H.-Y., Chen, Y., Qu, W., Feng, F., & Sun, H.-P. (2018) · ACS Medicinal Chemistry Letters · doi:10.1021/acsmedchemlett.7b00463 · Cited by 122
Multi-target neuroprotective effects of herbal medicines for Alzheimer's disease
Fernandes, F., Barroso, M. F., De Simone, A., Emriková, E., Dias-Teixeira, M., Pereira, J. P., Chlebek, J., Fernandes, V. C., Rodrigues, F., Andrisano, V., et al. (2022) · Journal of Ethnopharmacology · doi:10.1016/j.jep.2022.115107 · Cited by 45
Jiang, X., Zhou, J., Wang, Y., Chen, L., Duan, Y., Huang, J., Liu, C., Chen, Y., Liu, W., Sun, H., et al. (2020) · European Journal of Medicinal Chemistry · doi:10.1016/j.ejmech.2020.112751 · Cited by 39
Metadata
- Authors
- Baki, A., Bielik, A., Molnár, L., Szendrei, G., & Keserü, G. M.
- Venue
- ASSAY and Drug Development Technologies
- Publisher
- SAGE Publications
- Published
- 2007-02
- Volume
- 5
- Issue
- 1
- Pages
- 75-84
- ISSN
- 1540-658X (ISSN-L)
- 1557-8127
- OpenAlex
- W2073533877
- Cited by
- 125
- References
- 1
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A High Throughput Luminescent Assay for Glycogen Synthase Kinase-3 β Inhibitors. https://app.cochat.ai/papers/10.1089/adt.2006.029
- The paper
- Baki, A., Bielik, A., Molnár, L., Szendrei, G., & Keserü, G. M. (2007). A High Throughput Luminescent Assay for Glycogen Synthase Kinase-3 β Inhibitors. ASSAY and Drug Development Technologies. https://doi.org/10.1089/adt.2006.029
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.