CoChat

A Simple Statistical Parameter for Use in Evaluation and Validation of High Throughput Screening Assays.

Open access

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

The ability to identify active compounds (³hits²) from large chemical libraries accurately and rapidly has been the ultimate goal in developing high-throughput screening (HTS) assays. The ability to identify hits from a particular HTS assay depends largely on the suitability or quality of the assay used in the screening. The criteria or parameters for evaluating the ³suitability² of an HTS assay for hit identification are not well defined and hence it still remains difficult to compare the quality of assays directly. In this report, a screening window coefficient, called ³Z-factor,² is defined. This coefficient is reflective of both the assay signal dynamic range and the data variation associated with the signal measurements, and therefore is suitable for assay quality assessment. The Z-factor is a dimensionless, simple statistical characteristic for each HTS assay. The Z-factor provides a useful tool for comparison and evaluation of the quality of assays, and can be utilized in assay optimization and validation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/108705719900400206

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Figures

FIG. 1 Typical assay data from a single screen run in two different formats, A and B. The solid horizontal lines show the means of the sample and control (background) data in the two formats. Broken lines display 3 standard deviations (SD) from the mean of each data set. This data illustrates how the S/N or S/B ratios may be misleading in choosing the best format for the screen. The sample data in A has a mean of 50 with a 3 SD of 10, and in B the sample data has a mean of 100 with a 3 SD of 70. The control in both data sets has a mean of 10 with a 3 SD of 10. The S/N ratios are 12 and 27 and the S/B ratios are 5 and 10 for A and B respectively. By either S/N or S/B ratio, it would appear that the screen format that generated the data in B would be preferable for the screen. This error is due to the fact that neither the S/N nor the S/B ratio takes into account the variability in the sample data (which in many cases is different from that of the background). Empirically, and by calculation using the Z-factor, it is obvious that the screen format that generated the data in A is preferable for the screen.
FIG. 1 Typical assay data from a single screen run in two different formats, A and B. The solid horizontal lines show the means of the sample and control (background) data in the two formats. Broken lines display 3 standard deviations (SD) from the mean of each data set. This data illustrates how the S/N or S/B ratios may be misleading in choosing the best format for the screen. The sample data in A has a mean of 50 with a 3 SD of 10, and in B the sample data has a mean of 100 with a 3 SD of 70. The control in both data sets has a mean of 10 with a 3 SD of 10. The S/N ratios are 12 and 27 and the S/B ratios are 5 and 10 for A and B respectively. By either S/N or S/B ratio, it would appear that the screen format that generated the data in B would be preferable for the screen. This error is due to the fact that neither the S/N nor the S/B ratio takes into account the variability in the sample data (which in many cases is different from that of the background). Empirically, and by calculation using the Z-factor, it is obvious that the screen format that generated the data in A is preferable for the screen.CC-BY-NC-ND · From the PDF
FIG. 2 A normal distribution of test samples (A) with a chosen "hit limit"(solid vertical line) and sample points (broken lines) taken at X on either side of the hit limit. Compounds with activity the same as the hit limit (B) will have an approximately 50% chance of being declared a hit (shaded area in B). Compounds with activities at (hit limit + X) or (hit limit – X) will have a much higher or lower probability of being declared a hit (C and D), respectively.
FIG. 2 A normal distribution of test samples (A) with a chosen "hit limit"(solid vertical line) and sample points (broken lines) taken at X on either side of the hit limit. Compounds with activity the same as the hit limit (B) will have an approximately 50% chance of being declared a hit (shaded area in B). Compounds with activities at (hit limit + X) or (hit limit – X) will have a much higher or lower probability of being declared a hit (C and D), respectively.CC-BY-NC-ND · From the PDF
FIG. 3 The probability of correctly declaring a hit near the set "hit limit" of an HTS assay. In this diagram, the sample mean of the screened library lies somewhere to the left of the hit limit line (refer to Fig. 2). The horizontal axis displays activity away from the hit limit (h) in standard deviation (SD) units. The solid line (—) indicates the probability of a compound identified from the initial screen with activity greater than "h" being confirmed active on retest. The dashed line (----) indicates the probability of a compound being declared as having an activity above "h" in the primary assay when its "true" activity would be below "h" (false-positive), i.e., not confirmed on retest. The dotted line (…) indicates the probability of a compound with an activity less than "h" in the initial screen having a ""true" activity greater than "h"(false-negative). (Note that bias is built in because the compounds initially found below the hit limit aoxead + , e e o e ( s o oe es ar assay would have a 99.85% chance of having an activity greater than "h."A compound with an initial activity at "h" would have only a 50% chance of having an activity greater than "h" on retest. A compound with initial activity of "h - 1" would have a 16% chance of having an activity greater than "h."
FIG. 3 The probability of correctly declaring a hit near the set "hit limit" of an HTS assay. In this diagram, the sample mean of the screened library lies somewhere to the left of the hit limit line (refer to Fig. 2). The horizontal axis displays activity away from the hit limit (h) in standard deviation (SD) units. The solid line (—) indicates the probability of a compound identified from the initial screen with activity greater than "h" being confirmed active on retest. The dashed line (----) indicates the probability of a compound being declared as having an activity above "h" in the primary assay when its "true" activity would be below "h" (false-positive), i.e., not confirmed on retest. The dotted line (…) indicates the probability of a compound with an activity less than "h" in the initial screen having a ""true" activity greater than "h"(false-negative). (Note that bias is built in because the compounds initially found below the hit limit aoxead + , e e o e ( s o oe es ar assay would have a 99.85% chance of having an activity greater than "h."A compound with an initial activity at "h" would have only a 50% chance of having an activity greater than "h" on retest. A compound with initial activity of "h - 1" would have a 16% chance of having an activity greater than "h."CC-BY-NC-ND · From the PDF
FIG. 4 Illustration of the defined data variation band and separation band in an HTS assay. The letter denotation is the same as described in the text. Both the sample and control data is assumed to obey a normal distribution profile. This should be a good approximation for large unbiased sample sets. For a small sample set, a t-distribution model may need to be considered.
FIG. 4 Illustration of the defined data variation band and separation band in an HTS assay. The letter denotation is the same as described in the text. Both the sample and control data is assumed to obey a normal distribution profile. This should be a good approximation for large unbiased sample sets. For a small sample set, a t-distribution model may need to be considered.CC-BY-NC-ND · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 6,847

Metadata

Authors
Zhang, J.-H., Chung, T. D. Y., & Oldenburg, K. R.
Affiliations
DuPont (United States) (US)
Venue
SLAS Discovery
Publisher
Elsevier BV
Published
1999-04
Volume
4
Issue
2
Pages
67-73
ISSN
2472-5552 (ISSN-L)
OpenAlex
W1991001144
Cited by
6,847
References
8
Citations by year
2026: 200 · 2025: 267 · 2024: 257 · 2023: 308 · 2022: 355 · 2021: 346 · 2020: 358 · 2019: 343 · 2018: 350 · 2017: 339 · 2016: 365 · 2015: 330 · 2014: 347 · 2013: 373 · 2012: 354
FWCI
52.99
Type
journal article
Language
en
Open access
Licence
Locations
  • SLAS DISCOVERY (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Drug Discovery › Computational Drug Discovery Methods
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
  • Health Sciences › Veterinary › Small Animals › Animal testing and alternatives
Keywords
Z' factor, high-throughput screening, hit identification, signal dynamic range, assay validation, statistical parameters, assay optimization, chemical libraries

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Simple Statistical Parameter for Use in Evaluation and Validation of High Throughput Screening Assays. https://app.cochat.ai/papers/10.1177/108705719900400206
The paper
Zhang, J.-H., Chung, T. D. Y., & Oldenburg, K. R. (1999). A Simple Statistical Parameter for Use in Evaluation and Validation of High Throughput Screening Assays. SLAS Discovery. https://doi.org/10.1177/108705719900400206

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.