The Continuous Glucose Monitoring System During Pregnancy of Women with Type 1 Diabetes Mellitus: Accuracy Assessment
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The Continuous Glucose Monitoring System (CGMS, Medtronic MiniMed, Northridge, CA) allows close monitoring of glucose patterns and might be helpful in explaining the persistence of high complication rates in pregnancies of women with type 1 diabetes. It was the aim of this study to determine whether the CGMS accurately reflects glucose levels in pregnant women with type 1 diabetes mellitus. METHODS: Fifteen pregnant women with type 1 diabetes used the CGMS and were asked to determine at least seven fingerstick blood glucose levels each day, of which four were used for calibration. The patients were asked to keep a diary of the non-calibration blood glucose values. The accuracy of the CGMS was studied by comparing the non-calibration blood glucose values with simultaneously measured sensor glucose values using the Pearson correlation coefficient, the mean of absolute differences, and the Clarke error grid analysis. RESULTS: A total of 239 non-calibration blood glucose values were analyzed. The correlation coefficient between non-calibration blood glucose and sensor glucose value was 0.94 (P < 0.001). The mean of the absolute difference was 0.74 mmol/L. Of the non-calibration data 93.8% fell in the clinically acceptable zone of the Clarke error grid analysis. CONCLUSIONS: The CGMS is an accurate tool for additional glucose monitoring in pregnant women with type 1 diabetes mellitus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Management of dyslipidemia in children and adolescents with diabetes
American Diabetes Association (2003) · Diabetes Care · doi:10.2337/diacare.26.7.2194 · Cited by 438
Suhonen, L., Hiilesmaa, V., & Teramo, K. (2000) · Diabetologia · doi:10.1007/s001250050010 · Cited by 302
Evers, I. M., ter Braak, E. W. M. T., de Valk, H. W., van der Schoot, B., Janssen, N., & Visser, G. H. A. (2002) · Diabetes Care · doi:10.2337/diacare.25.3.554 · Cited by 152
Self-citationAccuracy of home blood glucose monitors
Tate, P. F., Clements, C. A., & Walters, J. E. (1992) · Diabetes Care · doi:10.2337/diacare.15.4.536 · Cited by 41
Cited by
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390
Farrar, D., Tuffnell, D. J., West, J., & West, H. M. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005542.pub3 · Cited by 194
The role of continuous glucose monitoring in clinical decision-making in diabetes in pregnancy
McLACHLAN, K., JENKINS, A., & O’NEAL, D. (2007) · Australian and New Zealand Journal of Obstetrics and Gynaecology · doi:10.1111/j.1479-828x.2007.00716.x · Cited by 82
Postprandial walking reduces glucose levels in women with gestational diabetes mellitus
Coe, D. P., Conger, S. A., Kendrick, J. M., Howard, B. C., Thompson, D. L., Bassett, D. R., & White, J. D. (2018) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2017-0494 · Cited by 34
Metadata
- Authors
- Kerssen, A., De Valk, H. W., & Visser, G. H. A.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2004-10
- Volume
- 6
- Issue
- 5
- Pages
- 645-651
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2166566671
- Cited by
- 56
- References
- 4
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.