The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Breath Ethanol and Acetone as Indicators of Serum Glucose Levels: An Initial Report
Open accessAbstract
BACKGROUND: Many volatile organic compounds are present in exhaled breath and may represent by-products of endogenous biological processes. Ethanol is produced via alcoholic fermentation of glucose by gut bacteria and yeast, while acetone derives from oxidations of free fatty acids, influenced by glucose metabolism. We hypothesized that the integrated analysis of breath ethanol and acetone would provide a good approximation of the blood glucose profile during a glucose load. METHODS: We collected simultaneous exhaled breath gas, ambient air, and serum glucose and insulin samples from 10 healthy volunteers at baseline and during an oral glucose tolerance test (OGTT) (ingestion of 75 g of glucose followed by 120 min of sampling). Gas samples were analyzed by gas chromatography/mass spectrometry. RESULTS: Mean glucose values displayed a typical OGTT pattern (rapid increase, peak values at 30-60 min, and gradual return to near baseline by 120 min). Breath ethanol displayed a similar pattern early in the test, with peak values at 30 min; this was followed by a fast return to basal levels by 60 min. Breath acetone decreased progressively below basal levels, with lowest readings obtained at 120 min. A multiple regression analysis of glucose, ethanol, and acetone was used to estimate glucose profiles that correlated with measured glucose values with an average individual correlation coefficient of 0.70, and not lower than 0.41 in any subject. CONCLUSION: The integrated analysis of multiple exhaled gases may serve as a marker of blood glucose levels. Further studies are needed to assess the usefulness of this method in different populations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
6Ketosis of starvation: A revisit and new perspectives
Owen, O. E., Caprio, S., Reichard, G. A., Mozzoli, M. A., Boden, G., & Owen, R. S. (1983) · Clinics in Endocrinology and Metabolism · doi:10.1016/s0300-595x(83)80046-2 · Cited by 116
Cited by
Sensors for Breath Testing: From Nanomaterials to Comprehensive Disease Detection
Konvalina, G., & Haick, H. (2014) · Accounts of Chemical Research · doi:10.1021/ar400070m · Cited by 561
Oxygen vacancy defects engineering on Ce-doped α-Fe2O3 gas sensor for reducing gases
Wang, X., Wang, T., Si, G., Li, Y., Zhang, S., Deng, X., & Xu, X. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2019.127165 · Cited by 367
Clinical Application of Volatile Organic Compound Analysis for Detecting Infectious Diseases
Sethi, S., Nanda, R., & Chakraborty, T. (2013) · Clinical Microbiology Reviews · doi:10.1128/cmr.00020-13 · Cited by 331
Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Shokrekhodaei, M., & Quinones, S. (2020) · Sensors · doi:10.3390/s20051251 · Cited by 221
Raninen, K., Lappi, J., Kolehmainen, M., Kolehmainen, M., Mykkänen, H., Poutanen, K., & Raatikainen, O. (2017) · International Journal of Food Sciences and Nutrition · doi:10.1080/09637486.2017.1312296 · Cited by 15
Metadata
- Authors
- Galassetti, P. R., Novak, B., Nemet, D., Rose-Gottron, C., Cooper, D. M., Meinardi, S., Newcomb, R., Zaldivar, F., & Blake, D. R.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2005-02
- Volume
- 7
- Issue
- 1
- Pages
- 115-123
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2015273834
- Cited by
- 229
- References
- 1
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Breath Ethanol and Acetone as Indicators of Serum Glucose Levels: An Initial Report. https://app.cochat.ai/papers/10.1089/dia.2005.7.115
- The paper
- Galassetti, P. R., Novak, B., Nemet, D., Rose-Gottron, C., Cooper, D. M., Meinardi, S., Newcomb, R., Zaldivar, F., & Blake, D. R. (2005). Breath Ethanol and Acetone as Indicators of Serum Glucose Levels: An Initial Report. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2005.7.115
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.