Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Open accessAbstract
Annual deaths in the U.S. attributed to diabetes are expected to increase from 280,210 in 2015 to 385,840 in 2030. The increase in the number of people affected by diabetes has made it one of the major public health challenges around the world. Better management of diabetes has the potential to decrease yearly medical costs and deaths associated with the disease. Non-invasive methods are in high demand to take the place of the traditional finger prick method as they can facilitate continuous glucose monitoring. Research groups have been trying for decades to develop functional commercial non-invasive glucose measurement devices. The challenges associated with non-invasive glucose monitoring are the many factors that contribute to inaccurate readings. We identify and address the experimental and physiological challenges and provide recommendations to pave the way for a systematic pathway to a solution. We have reviewed and categorized non-invasive glucose measurement methods based on: (1) the intrinsic properties of glucose, (2) blood/tissue properties and (3) breath acetone analysis. This approach highlights potential critical commonalities among the challenges that act as barriers to future progress. The focus here is on the pertinent physiological aspects, remaining challenges, recent advancements and the sensors that have reached acceptable clinical accuracy.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The major problem with non-invasive optical sensors is the specific measurement of glucose with sufficient analytical quality.
“The major problem with non‐invasive optical sensors is the specific measurement of glucose with sufficient analytical quality 109.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [109]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
IDF Diabetes Atlas: Global estimates of diabetes prevalence for 2017 and projections for 2045
Cho, N. H., Shaw, J. E., Karuranga, S., Huang, Y., da Rocha Fernandes, J. D., Ohlrogge, A. W., & Malanda, B. (2018) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2018.02.023 · Cited by 7,283 · see citing works
Insulin signalling and the regulation of glucose and lipid metabolism
Saltiel, A. R., & Kahn, C. R. (2001) · Nature · doi:10.1038/414799a · Cited by 5,326 · see citing works
Gabriel, S., Lau, R.-W.-M., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,487 · see citing works
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008 · see citing works
2. Classification and Diagnosis of Diabetes: <i>Standards of Medical Care in Diabetes—2018</i>
American Diabetes Association (2018) · Diabetes Care · doi:10.2337/dc18-s002 · Cited by 3,159 · see citing works
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435 · see citing works
Raman and infrared spectroscopy of carbohydrates: A review
Wiercigroch, E., Szafraniec, E., Czamara, K., Pacia, M. Z., Majzner, K., Kochan, K., Kaczor, A., Barańśka, M., & Małek, K. (2017) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2017.05.045 · Cited by 1,078 · see citing works
The definition of anemia: what is the lower limit of normal of the blood hemoglobin concentration?
Beutler, E., & Waalen, J. (2005) · Blood · doi:10.1182/blood-2005-07-3046 · Cited by 971 · see citing works
Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
Pogue, B. W., & Patterson, M. S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2335429 · Cited by 842 · see citing works
Gonzales, W. V., Mobashsher, A. T., & Abbosh, A. M. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 788 · see citing works
Glucose Sensing for Diabetes Monitoring: Recent Developments
Bruen, D., Delaney, C., Florea, L., & Diamond, D. (2017) · Sensors · doi:10.3390/s17081866 · Cited by 778 · see citing works
Diabetes 2030: Insights from Yesterday, Today, and Future Trends
Rowley, W. R., Bezold, C., Arikan, Y., Byrne, E. N., & Krohe, S. (2016) · Population Health Management · doi:10.1089/pop.2015.0181 · Cited by 662 · see citing works
Dieringer, J. A., McFarland, A. D., Shah, N. C., Stuart, D. A., Whitney, A. V., Yonzon, C. R., Young, M. A., Zhang, X., & Duyne, R. P. V. (2005) · Faraday Discussions · doi:10.1039/b513431p · Cited by 598 · see citing works
Wearable non-invasive epidermal glucose sensors: A review
Kim, J., Campbell, A. S., & Wang, J. (2017) · Talanta · doi:10.1016/j.talanta.2017.08.077 · Cited by 585 · see citing works
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584 · see citing works
Anatomy and Physiology of the Skin
Kolarsick, P. A. J., Kolarsick, M. A., & Goodwin, C. (2011) · Journal of the Dermatology Nurses' Association · doi:10.1097/jdn.0b013e3182274a98 · Cited by 578 · see citing works
Diabetic emergencies - ketoacidosis, hyperglycaemic hyperosmolar state and hypoglycaemia
Umpierrez, G., & Korytkowski, M. (2016) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2016.15 · Cited by 563 · cited 1× · see citing works
“Very high and dangerous levels of blood ketones can decrease plasma pH to low levels, and this can lead to coma or death if not reversed [41].”
BackgroundArtificial intelligence for diabetes management and decision support: Literature review
Contreras, I., & Vehi, J. (2018) · Journal of Medical Internet Research · doi:10.2196/10775 · Cited by 560 · see citing works
Diabetes mellitus and electrolyte disorders
Liamis, G. L. (2014) · World Journal of Clinical Cases · doi:10.12998/wjcc.v2.i10.488 · Cited by 406 · see citing works
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390 · see citing works
Electric Properties of Tissues
Damijan Miklavčič, A., Pavšelj, N., & Hart, F. X. (2006) · Wiley Encyclopedia of Biomedical Engineering · doi:10.1002/9780471740360.ebs0403 · Cited by 379 · see citing works
Optical glucose sensing in biological fluids: an overview
McNichols, R. J., & Coté, G. L. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429962 · Cited by 369 · see citing works
Wiley Encyclopedia of Biomedical Engineering
Çetin, A. E., & Gerek, O. N. (2006) · Wiley eBooks · doi:10.1002/9780471740360 · Cited by 369 · see citing works
Tuchin, V. V. (2007) · SPIE eBooks · doi:10.1117/3.684093 · Cited by 349 · see citing works
An overview of dielectric properties measuring techniques
Raghavan, M. S. V. A. G. S. V. (2005) · Cited by 331 · see citing works
Maier, J., Walker, S. A., Fantini, S., Franceschini, M. A., & Gratton, E. (1994) · Optics Letters · doi:10.1364/ol.19.002062 · Cited by 318 · see citing works
Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor
Choi, H., Naylon, J. A., Luzio, S. D., Beutler, J., Birchall, J. C., Martin, C., & Porch, A. (2015) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2015.2472019 · Cited by 313 · see citing works
Gioia, A. L., Porter, E., Merunka, I., Shahzad, A., Salahuddin, S., Jones, M., & O’Halloran, M. (2018) · Diagnostics · doi:10.3390/diagnostics8020040 · Cited by 305 · see citing works
Electrical impedance spectroscopy study of biological tissues
Dean, D. A., Ramanathan, T., Machado, D., & Sundararajan, R. (2008) · Journal of Electrostatics · doi:10.1016/j.elstat.2007.11.005 · Cited by 300 · see citing works
Noninvasive Blood Glucose Monitoring With Optical Coherence Tomography
Larin, K. V., Eledrisi, M. S., Motamedi, M., & Esenaliev, R. O. (2002) · Diabetes Care · doi:10.2337/diacare.25.12.2263 · Cited by 293 · see citing works
Noninvasive Monitoring of Blood Glucose with Raman Spectroscopy
Pandey, R., Paidi, S. K., Valdez, T. A., Zhang, C., Spegazzini, N., Dasari, R. R., & Barman, I. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00472 · Cited by 290 · see citing works
Microwave-Based Noninvasive Concentration Measurements for Biomedical Applications
Hofmann, M., Fischer, G., Weigel, R., & Kissinger, D. (2013) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2013.2250516 · Cited by 289 · see citing works
Sensors for glucose monitoring: technical and clinical aspects
Koschinsky, T., & Heinemann, L. (2001) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.188 · Cited by 288 · see citing works
Sensing Technologies for Detection of Acetone in Human Breath for Diabetes Diagnosis and Monitoring
Saasa, V., Malwela, T., Beukes, M., Mokgotho, M. P., Liu, C.-P., & Mwakikunga, B. W. (2018) · Diagnostics · doi:10.3390/diagnostics8010012 · Cited by 288 · see citing works
Tura, A., Maran, A., & Pacini, G. (2007) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2006.10.027 · Cited by 283 · see citing works
Continuous Glucose Monitoring Systems: A Review
Vashist, S. (2013) · Diagnostics · doi:10.3390/diagnostics3040385 · Cited by 261 · see citing works
Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 256 · see citing works
Analysis of optical coherence tomography systems based on the extended Huygens–Fresnel principle
Thrane, L., Yura, H. T., & Andersen, P. E. (2000) · Journal of the Optical Society of America A · doi:10.1364/josaa.17.000484 · Cited by 248 · see citing works
First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system
Caduff, A., Hirt, E., Feldman, Y. D., Ali, Z., & Heinemann, L. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00196-9 · Cited by 248 · see citing works
Functionalized conjugated polymers for sensing and molecular imprinting applications
Anantha-Iyengar, G., Shanmugasundaram, K., Nallal, M., Lee, K.-P., Whitcombe, M. J., Lakshmi, D., & Saianand, G. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.08.001 · Cited by 239 · see citing works
Wang, C., Mbi, A., & Shepherd, M. D. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2035730 · Cited by 236 · see citing works
Dielectric measurements with an open-ended coaxial probe
Marsland, T. P., & Evans, S. D. (1987) · IEE Proceedings H Microwaves Antennas and Propagation · doi:10.1049/ip-h-2.1987.0068 · Cited by 231 · see citing works
Breath Ethanol and Acetone as Indicators of Serum Glucose Levels: An Initial Report
Galassetti, P. R., Novak, B., Nemet, D., Rose-Gottron, C. M., Cooper, D. M., Meinardi, S., Newcomb, R. L., Zaldivar, F. P., & Blake, D. R. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.115 · Cited by 229 · see citing works
EM-Wave Biosensors: A Review of RF, Microwave, mm-Wave and Optical Sensing
Mehrotra, P., Chatterjee, B., & Sen, S. (2019) · Sensors · doi:10.3390/s19051013 · Cited by 222 · see citing works
Recent advances in noninvasive glucose monitoring
Chung, J. W. Y., So, H., Choi, K., & Wong, T. K. S. (2012) · Medical Devices Evidence and Research · doi:10.2147/mder.s28134 · Cited by 221 · see citing works
Jeong, J. W., Arnob, M. M. P., Baek, K. M., Lee, S. Y., Shih, W., & Jung, Y. S. (2016) · Advanced Materials · doi:10.1002/adma.201602603 · Cited by 221 · see citing works
Hepatic and whole-body fat synthesis in humans during carbohydrate overfeeding
Aarsland, A. A., Chinkes, D. L., & Wolfe, R. R. (1997) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/65.6.1774 · Cited by 202 · see citing works
Rothwell, E. J., Frasch, J. L., Ellison, S. M., Chahal, P. P., & Ouedraogo, R. O. (2016) · Electromagnetic waves · doi:10.2528/pier16071706 · Cited by 201 · see citing works
Radio-Frequency and Microwave Techniques for Non-Invasive Measurement of Blood Glucose Levels
Yilmaz, T., Foster, R., & Hao, Y. (2019) · Diagnostics · doi:10.3390/diagnostics9010006 · Cited by 195 · see citing works
Lazebnik, M., Converse, M., Booske, J. H., & Hagness, S. C. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/7/022 · Cited by 194 · see citing works
Turner, C., Walton, C., Hoashi, S., & Evans, M. L. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/4/046004 · Cited by 183 · see citing works
Neural Network-Based Real-Time Prediction of Glucose in Patients with Insulin-Dependent Diabetes
Pappada, S. M., Cameron, B. D., Rosman, P. M., Bourey, R. E., Papadimos, T. J., Olorunto, W. A., & Borst, M. J. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0104 · Cited by 182 · see citing works
Juan, C. G., Bronchalo, E., Potelon, B., Quendo, C., Ávila-Navarro, E., & Sabater-Navarro, J. M. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2866743 · Cited by 177 · see citing works
Saha, S. C., Cano-Garcia, H., Sotiriou, I., Lipscombe, O., Gouzouasis, I. A., Κουτσουπίδου, Μ., Palikaras, G. K., Mackenzie, R., Reeve, T., Kosmas, P., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-06926-1 · Cited by 174 · see citing works
In Vivo Blood Glucose Quantification Using Raman Spectroscopy
Shao, J., Lin, M., Li, Y.-Q., Li, X., Liu, J., Liang, J., & Yao, H. (2012) · PLoS ONE · doi:10.1371/journal.pone.0048127 · Cited by 172 · see citing works
Yilmaz, T., Foster, R., & Hao, Y. (2014) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2014.2313139 · Cited by 168 · see citing works
Optical coherence tomography angiography: a review of current and future clinical applications
Ang, M., Tan, A. C. S., Cheung, C. M. G., Keane, P. A., Dolz‐Marco, R., Sng, C. C. A., & Schmetterer, L. F. (2018) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-017-3896-2 · Cited by 167 · see citing works
Exhaled methyl nitrate as a noninvasive marker of hyperglycemia in type 1 diabetes
Novak, B., Blake, D. R., Meinardi, S., Rowland, F. S., Pontello, A. M., Cooper, D. M., & Galassetti, P. R. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706533104 · Cited by 164 · see citing works
Sim, J. Y., Ahn, C.-G., Jeong, E.-J., & Kim, B. K. (2018) · Scientific Reports · doi:10.1038/s41598-018-19340-y · Cited by 164 · see citing works
Smolinska, A., Klaassen, E. M. M., Dallinga, J. W., van de Kant, K. D. G., Jöbsis, Q., Moonen, E. J. C., van Schayck, O. C. P., Dompeling, E., & van Schooten, F. (2014) · PLoS ONE · doi:10.1371/journal.pone.0095668 · Cited by 163 · see citing works
Caduff, A., Dewarrat, F., Talary, M., Stalder, G., Heinemann, L., & Feldman, Y. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.031 · Cited by 155 · see citing works
The Appearance of Human Skin: A Survey
Igarashi, T., Nishino, K., & Nayar, S. K. (2007) · Foundations and Trends® in Computer Graphics and Vision · doi:10.1561/0600000013 · Cited by 154 · see citing works
Electromagnetic Characterisation of Materials by Using Transmission/Reflection (T/R) Devices
Costa, F., Borgese, M., Degiorgi, M., & Monorchio, A. (2017) · Electronics · doi:10.3390/electronics6040095 · Cited by 154 · see citing works
Atchudan, R., Nallal, M., Edison, T. N. J. I., Perumal, S., Vinodh, R., Park, K. H., & Lee, Y. R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.049 · Cited by 153 · see citing works
Busher, J. T. (1990) · Cited by 149 · see citing works
Silicon-Based Sensors for Biomedical Applications: A Review
Xu, Y., Hu, X., Kundu, S., Nag, A., Afsarimanesh, N., Sapra, S., Mukhopadhyay, S. C., & Han, T. (2019) · Sensors · doi:10.3390/s19132908 · Cited by 148 · see citing works
Larin, K. V., Motamedi, M., Ashitkov, T. V., & Esenaliev, R. O. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/10/310 · Cited by 147 · see citing works
Linear birefringence of the central human cornea.
Knighton, R. W., & Huang, X.-R. (2002) · PubMed · Cited by 147 · see citing works
Enhanced acetone sensing properties of titanium dioxide nanoparticles with a sub-ppm detection limit
Navale, S. T., Yang, Z., Liu, C., Cao, P., Patil, V. B., Ramgir, N. S., Mane, R. S., & Stadler, F. J. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.08.186 · Cited by 147 · see citing works
Non-Invasive Glucose Monitoring: A Review of Challenges and Recent Advances
Lin, T. (2017) · Current Trends in Biomedical Engineering & Biosciences · doi:10.19080/ctbeb.2017.06.555696 · Cited by 144 · see citing works
Dielectric spectroscopy study of specific glucose influence on human erythrocyte membranes
Hayashi, Y., Livshits, L., Caduff, A., & Feldman, Y. D. (2003) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/36/4/307 · Cited by 142 · see citing works
Rapid acetone detection using indium loaded WO3/SnO2 nanohybrid sensor
Tomer, V. K., Singh, K., Kaur, H., Shorie, M., & Sabherwal, P. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.06.179 · Cited by 137 · see citing works
A microwave frequency sensor for non-invasive blood-glucose measurement
Jean, B. R., Green, E. C., & McClung, M. J. (2008) · IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas.2008.4472932 · Cited by 133 · see citing works
Mid-Infrared Photoacoustic Detection of Glucose in Human Skin: Towards Non-Invasive Diagnostics
Kottmann, J., Rey, J. M., & Sigrist, M. W. (2016) · Sensors · doi:10.3390/s16101663 · Cited by 133 · see citing works
Multivariate calibration of NIR spectroscopic sensors for continuous glucose monitoring
Goodarzi, M., Sharma, S., Ramón, H., & Saeys, W. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.12.005 · Cited by 132 · see citing works
Microscopic Imaging and Spectroscopy with Scattered Light
Boustany, N. N., Boppart, S. A., & Backman, V. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124811 · Cited by 131 · see citing works
PrFeO3 hollow nanofibers as a highly efficient gas sensor for acetone detection
Ma, L., Ma, S. Y., Shen, X. F., Wang, T. T., Jiang, X., Chen, Q., Qiang, Z., Yang, H., & Chen, H. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.09.060 · Cited by 128 · see citing works
Glucose-dependent dielectric properties of blood plasma
Topsakal, E., Karacolak, T., & Moreland, E. C. (2011) · doi:10.1109/ursigass.2011.6051324 · Cited by 127 · see citing works
The Appearance of Human Skin: A Survey
Igarashi, T., Nishino, K., & Nayar, S. K. (2007) · now publishers, Inc. eBooks · doi:10.1561/9781601980878 · Cited by 124 · see citing works
Continuous Noninvasive Glucose Monitoring Technology Based on “Occlusion Spectroscopy”
Amir, O., Weinstein, D., Zilberman, S., Less, M., Perl‐Treves, D., Primack, H., Weinstein, A., Gabis, E., Fikhte, B. A., & Karasik, A. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100403 · Cited by 123 · see citing works
Noninvasive glucose monitoring using mid-infrared absorption spectroscopy based on a few wavenumbers
Kasahara, R., Kino, S., Soyama, S., & Matsuura, Y. (2017) · Biomedical Optics Express · doi:10.1364/boe.9.000289 · Cited by 123 · see citing works
Measuring airway exchange of endogenous acetone using a single-exhalation breathing maneuver
Anderson, J. C., Lamm, W. J., & Hlastala, M. P. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00868.2005 · Cited by 118 · see citing works
Götzinger, E., Pircher, M., Sticker, M., FERCHER, A. F., & Hitzenberger, C. K. F. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1629308 · Cited by 118 · see citing works
En face optical coherence tomography: a technology review [Invited]
Leitgeb, R. A. (2019) · Biomedical Optics Express · doi:10.1364/boe.10.002177 · Cited by 118 · see citing works
A Deep Learning Approach to Diabetic Blood Glucose Prediction
Mhaskar, H. N., Pereverzev, S. V., & van der Walt, M. D. (2017) · Frontiers in Applied Mathematics and Statistics · doi:10.3389/fams.2017.00014 · Cited by 117 · see citing works
Song, K., Ha, U., Park, S., Bae, J., & Yoo, H. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2384037 · Cited by 115 · see citing works
BEVING, H. F. G., Eriksson, L. E. G., Davey, C. L., & Kell, D. B. (1994) · European Biophysics Journal · doi:10.1007/bf01007612 · Cited by 113 · see citing works
Near-infrared LED based non-invasive blood glucose sensor
Yadav, J., Rani, A., Singh, V., & Murari, B. M. (2014) · International Conference on Signal Processing and Integrated Networks (SPIN) · doi:10.1109/spin.2014.6777023 · Cited by 112 · see citing works
Glucose Sensing Using Surface-Enhanced Raman-Mode Constraining
Yang, D., Afroosheh, S., Lee, J. O., Cho, H., Kumar, S., Siddique, R. H., Narasimhan, V., Yoon, Y.-Z., Zayak, A. T., & Choo, H. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03420 · Cited by 111 · see citing works
Caduff, A., Talary, M. S., Mueller, M. C., Dewarrat, F., Klisic, J., Donath, M. Y., Heinemann, L., & Stahel, W. A. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.02.001 · Cited by 109 · see citing works
Yi, J., & Backman, V. (2012) · Optics Letters · doi:10.1364/ol.37.004443 · Cited by 106 · see citing works
Zarkogianni, K., Mitsis, K., Litsa, E. E., Arredondo, M. T., Fico, G., Fioravanti, A., & Nikita, K. S. (2015) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1320-9 · Cited by 106 · see citing works
Precision of measurement of tissue optical properties with optical coherence tomography
Kholodnykh, A. I., Petrova, I. Y., Larin, K. V., Motamedi, M., & Esenaliev, R. O. (2003) · Applied Optics · doi:10.1364/ao.42.003027 · Cited by 106 · see citing works
Li, N., Zang, H., Sun, H., Jiao, X., Wang, K., Liu, T. C., & Meng, Y. (2019) · Molecules · doi:10.3390/molecules24081500 · Cited by 103 · see citing works
Rydosz, A. M. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815572366 · Cited by 100 · see citing works
Reagentless Near-Infrared Determination of Glucose in Whole Blood Using Multivariate Calibration
Haaland, D. M., Robinson, M., Koepp, G. W., Thomas, E. V., & Eaton, R. P. (1992) · Applied Spectroscopy · doi:10.1366/000370292789619232 · Cited by 99 · see citing works
Dielectric properties of blood: an investigation of haematocrit dependence
Jaspard, F., Nadi, M., & Rouane, A. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/1/310 · Cited by 98 · see citing works
Temperature-Corrected Fluidic Glucose Sensor Based on Microwave Resonator
Jang, C., Park, J., Lee, H., Yun, G., & Yook, J. (2018) · Sensors · doi:10.3390/s18113850 · Cited by 97 · see citing works
A Novel Noninvasive Blood Glucose Monitor
Malchoff, C. D., Shoukri, K., Landau, J. I., & Buchert, J. M. (2002) · Diabetes Care · doi:10.2337/diacare.25.12.2268 · Cited by 96 · see citing works
Towards Accurate Dielectric Property Retrieval of Biological Tissues for Blood Glucose Monitoring
Yilmaz, T., Foster, R., & Hao, Y. (2014) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2014.2365019 · Cited by 94 · see citing works
Linear techniques to correct for temperature-induced spectral variation in multivariate calibration
Wülfert, F., Kok, W. T., de Noord, O. E., & Smilde, A. K. (2000) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(00)00069-1 · Cited by 92 · see citing works
Pendra goes Dutch: lessons for the CE mark in Europe
Wentholt, I. M. E., Hoekstra, J. B. L., Zwart, A., & DeVries, J. H. (2005) · Diabetologia · doi:10.1007/s00125-005-1754-y · Cited by 90 · see citing works
Advances in surface-enhanced Raman spectroscopy for analysis of pharmaceuticals: A review
Alula, M. T., Mengesha, Z. T., & Mwenesongole, E. M. (2018) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2018.06.013 · Cited by 90 · see citing works
A Noninvasive Measurement of Blood Glucose Concentration by UWB Microwave Spectrum
Xiao, X., & Li, Q. (2016) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2016.2618946 · Cited by 86 · see citing works
Harman‐Boehm, I., Gal, A., Raykhman, A. M., Naidis, E., & Mayzel, Y. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400312 · Cited by 85 · see citing works
Noninvasive Polarimetric-Based Glucose Monitoring: An in Vivo Study
Purvinis, G., Cameron, B. D., & Altrogge, D. M. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500227 · Cited by 83 · see citing works
Cobelli, C., Schiavon, M., Man, C. D., Basu, A., & Basu, R. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0112 · Cited by 83 · see citing works
Critical-depth Raman spectroscopy enables home-use non-invasive glucose monitoring
Lundsgaard-Nielsen, S. M., Pors, A., Banke, S. O., Henriksen, J. E., Hepp, D. K., & Weber, A. (2018) · PLoS ONE · doi:10.1371/journal.pone.0197134 · Cited by 83 · see citing works
Dielectric properties of blood: an investigation of temperature dependence
Jaspard, F., & Nadi, M. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/3/306 · Cited by 82 · see citing works
Study of the Exhaled Acetone in Type 1 Diabetes Using Quantum Cascade Laser Spectroscopy
Reyes-Reyes, A., Horsten, R., Urbach, H. P., & Bhattacharya, N. (2014) · Analytical Chemistry · doi:10.1021/ac504235e · Cited by 81 · see citing works
Quantifying the Composition of Human Skin for Glucose Sensor Development
Groenendaal, W., von Basum, G., Schmidt, K. A., Hilbers, P. A. J., & van Riel, N. A. W. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400502 · Cited by 79 · see citing works
Microwave noninvasive blood glucose monitoring sensor: Human clinical trial results
Choi, H., Luzio, S. D., Beutler, J., & Porch, A. (2017) · IEEE MTT-S International Microwave Symposium digest · doi:10.1109/mwsym.2017.8058721 · Cited by 77 · see citing works
Effect of temperature, pH, and corneal birefringence on polarimetric glucose monitoring in the eye
Baba, J. S., Cameron, B. D., & Coté, G. L. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1484163 · Cited by 76 · see citing works
Rogers, J. D., Radosevich, A. J., Yi, J., & Backman, V. (2013) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2013.2280999 · Cited by 76 · see citing works
Maruo, K., & Yamada, Y. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.4.047003 · Cited by 73 · see citing works
Storer, M., Dummer, J. F., Lunt, H., Scotter, J., McCartin, F., Cook, J., Swanney, M. P., Kendall, D., Logan, F. J., & Epton, M. (2011) · Journal of Breath Research · doi:10.1088/1752-7155/5/4/046011 · Cited by 72 · see citing works
Infrared Spectroscopy in Clinical and Diagnostic Analysis
Shaw, R. A., & Mantsch, H. H. (2000) · Encyclopedia of Analytical Chemistry · doi:10.1002/9780470027318.a0106 · Cited by 72 · see citing works
Impedance spectroscopy of solutions at physiological glucose concentrations
Tura, A., Sbrignadello, S., Barison, S., Conti, S., & Pacini, G. (2007) · Biophysical Chemistry · doi:10.1016/j.bpc.2007.06.001 · Cited by 70 · see citing works
Measurements of the corneal birefringence with a liquid-crystal imaging polariscope
Bueno, J. M., & Vargas-Martı́n, F. (2002) · Applied Optics · doi:10.1364/ao.41.000116 · Cited by 70 · see citing works
A novel multicomponent redox polymer nanobead based high performance non-enzymatic glucose sensor
Gopalan, A., Nallal, M., Komathi, S., & Lee, K.-P. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.079 · Cited by 68 · see citing works
Cylindrical Dielectric Resonator Antenna Sensor for Non-Invasive Glucose Sensing Application
Hasan, M. N., Tamanna, S., Singh, P., Nadeem, M. D., & Rudramuni, M. (2019) · International Conference on Signal Processing and Integrated Networks (SPIN) · doi:10.1109/spin.2019.8711633 · Cited by 68 · see citing works
Fibroblast Cells: A Sensing Bioelement for Glucose Detection by Impedance Spectroscopy
Tlili, C., Reybier, K., Géloën, A., Ponsonnet, L., Martelet, C., Ouada, H. B., Lagarde, M., & Jaffrezic-Renault, N. J. (2003) · Analytical Chemistry · doi:10.1021/ac0340861 · Cited by 66 · see citing works
Reyes-Vera, E., Acevedo-Osorio, G., Arias-Correa, M., & Senior, D. E. (2019) · Sensors · doi:10.3390/s19081936 · Cited by 66 · see citing works
Investigation of the effect of dehydration on tissue dielectric properties in ex vivo measurements
Shahzad, A., Khan, S., Jones, M., Dwyer, R. M., & O’Halloran, M. (2017) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aa74c4 · Cited by 64 · see citing works
Nirala, N., Periyasamy, R., Singh, B. K., & Kumar, A. (2018) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2018.09.007 · Cited by 63 · see citing works
Glucose Concentration Measurement in Human Blood Plasma Solutions with Microwave Sensors
Juan, C. G., Bronchalo, E., Potelon, B., Quendo, C., & Sabater-Navarro, J. M. (2019) · Sensors · doi:10.3390/s19173779 · Cited by 63 · see citing works
Monitoring of glucose permeability in monkey skin in vivo using Optical Coherence Tomography
Ghosn, M. G., Sudheendran, N., Wendt, M., Glasser, A., Tuchin, V. V., & Larin, K. V. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910075 · Cited by 63 · see citing works
A Biophysically‐Based Model of the Optical Properties of Skin Aging
Iglesias-Guitián, J. A., Aliaga, C., Jarabo, A., & Gutiérrez, D. (2015) · Computer Graphics Forum · doi:10.1111/cgf.12540 · Cited by 62 · see citing works
Millimeter-wave non-invasive monitoring of glucose in anesthetized rats
Siegel, P. H., Lee, Y., & Pikov, V. (2014) · International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz) · doi:10.1109/irmmw-thz.2014.6956294 · Cited by 62 · see citing works
Turgul, V., & Kale, İ. (2016) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2016.7520546 · Cited by 62 · see citing works
Geng, Z., Tang, F., Ding, Y., Li, S., & Wang, X. (2017) · Scientific Reports · doi:10.1038/s41598-017-13018-7 · Cited by 61 · see citing works
Sun, M., Chen, Z., Gong, Z., Zhao, X., Jiang, C., Yuan, Y., Wang, Z., Li, Y., & Wang, C. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-8401-8 · Cited by 61 · see citing works
Song, K., Ha, U., Park, S., & Yoo, H. (2014) · Symposium on VLSI Circuits · doi:10.1109/vlsic.2014.6858407 · Cited by 60 · see citing works
Li, J., Igbe, T., Liu, Y., Nie, Z., Qin, W., Wang, L., & Hao, Y. (2018) · IEEE Access · doi:10.1109/access.2018.2866601 · Cited by 60 · see citing works
Jiang, C., Sun, M., Wang, Z., Chen, Z., Zhao, X., Yuan, Y., Li, Y., & Wang, C. (2016) · Sensors · doi:10.3390/s16081199 · Cited by 60 · see citing works
A cross-sectional study of breath acetone based on diabetic metabolic disorders
Li, W., Liu, Y., Lu, X., Huang, Y., Liu, Y., Cheng, S.-Q., & Duan, Y. (2015) · Journal of Breath Research · doi:10.1088/1752-7155/9/1/016005 · Cited by 57 · see citing works
Blood Glucose Measurement Using Bioimpedance Technique
Kamat, D. K., Bagul, D., & Patil, P. M. (2014) · Advances in Electronics · doi:10.1155/2014/406257 · Cited by 56 · see citing works
Requirements for Calibration in Noninvasive Glucose Monitoring by Raman Spectroscopy
Lipson, J., Bernhardt, J., Block, U. L., Freeman, W. R., Hofmeister, R. T., Hristakeva, M., Lenosky, T. J., McNamara, R., Petrasek, D., Veltkamp, D. J., et al. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300203 · Cited by 56 · see citing works
Device and method for noninvasive glucose assessment
Segman, Y. (. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818763457 · Cited by 55 · see citing works
Stokes-Mueller matrix polarimetry system for glucose sensing
Phan, Q.-H., & Lo, Y. (2016) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2016.08.017 · Cited by 54 · see citing works
Dielectric inspection of erythrocyte morphology
Hayashi, Y., Oshige, I., Katsumoto, Y., Omori, S., Yasuda, A., & Asami, K. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/10/007 · Cited by 53 · see citing works
Jonasson, H., Fredriksson, I., Bergstrand, S., Östgren, C. J., Larsson, M., & Strömberg, T. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.12.121608 · Cited by 52 · see citing works
Review: Non-Invasive Continuous Blood Glucose Measurement Techniques
Nawaz, A., Øhlckers, P. A., Sælid, S., Jacobsen, M., & Akram, M. N. (2016) · Journal of Bioinformatics and Diabetes · doi:10.14302/issn.2374-9431.jbd-15-647 · Cited by 51 · see citing works
Forst, T., Caduff, A., Talary, M., Weder, M., Brändle, M., Kann, P., Flacke, F., Friedrich, C., & Pfützner, A. (2006) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.8.94 · Cited by 51 · see citing works
Kuranov, R. V., Sapozhnikova, V. V., Prough, D. S., Cicenaite, I., & Esenaliev, R. O. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/16/001 · Cited by 50 · see citing works
Saager, R. B., Quach, A., Rowland, R. A., Baldado, M. L., & Durkin, A. J. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.6.067001 · Cited by 49 · see citing works
Nallal, M., Gopalan, A., & Lee, K.-P. (2018) · RSC Advances · doi:10.1039/c7ra09097h · Cited by 49 · see citing works
Noninvasive measurement of glucose concentration on human fingertip by optical coherence tomography
Chen, T.-L., Lo, Y., Liao, C.-C., & Phan, Q.-H. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.4.047001 · Cited by 49 · see citing works
Computing the Surveillance Error Grid Analysis
Kovatchev, B. P., WAKEMAN, C. A., Breton, M. D., Kost, G. J., Louie, R. F., Tran, N. K., & Klonoff, D. C. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814539590 · Cited by 47 · see citing works
Conformal and Disposable Antenna-Based Sensor for Non-Invasive Sweat Monitoring
Eldamak, A. R. A. M. A., & Fear, E. C. (2018) · Sensors · doi:10.3390/s18124088 · Cited by 47 · see citing works
Lan, Y., Kuang, Y., Zhou, L. P., Wu, G., Gu, P., Wei, H., & Chen, K. (2017) · Laser Physics Letters · doi:10.1088/1612-202x/aa58c0 · Cited by 47 · see citing works
Basic Concepts in Clinical Biochemistry: A Practical Guide
Kumar, V., & Gill, K. D. (2018) · Springer eBooks · doi:10.1007/978-981-10-8186-6 · Cited by 47 · see citing works
Highly-Sensitive Glucose Concentration Sensor Exploiting Inter-resonators Couplings
Juan, C. G., Potelon, B., Quendo, C., Bronchalo, E., & Sabater-Navarro, J. M. (2019) · European Microwave Conference (EuMC) · doi:10.23919/eumc.2019.8910847 · Cited by 47 · see citing works
Cutaneous Blood Perfusion as a Perturbing Factor for Noninvasive Glucose Monitoring
Caduff, A., Talary, M. S., & Zakharov, P. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0095 · Cited by 46 · see citing works
Komathi, S., Gopalan, A., Nallal, M., & Lee, K.-P. (2017) · RSC Advances · doi:10.1039/c6ra24760a · Cited by 43 · see citing works
Torul, H., Çiftçi, H., Dudak, F. C., Adıgüzel, Y., Külah, H., Boyacı, İ. H., & Tamer, U. (2014) · Analytical Methods · doi:10.1039/c4ay00559g · Cited by 39 · see citing works
Exhaled Breath Isoprene Rises During Hypoglycemia in Type 1 Diabetes
Neupane, S., Peverall, R., Richmond, G., Blaikie, T. P. J., Taylor, D., Hancock, G., & Evans, M. L. (2016) · Diabetes Care · doi:10.2337/dc16-0461 · Cited by 39 · see citing works
Modeling and Measurement of Correlation between Blood and Interstitial Glucose Changes
Shi, T., Li, D., Li, G., Zhang, Y., Xu, K., & Lu, L. (2016) · Journal of Diabetes Research · doi:10.1155/2016/4596316 · Cited by 38 · see citing works
Wan, X., Li, G., Zhang, M., Yan, W., He, G., Awelisah, Y. M., & Lin, L. (2019) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2019.1584567 · Cited by 38 · see citing works
Balaguera, E. H., López‐Dolado, E., & Polo, J. L. (2016) · RSC Advances · doi:10.1039/c5ra24535d · Cited by 38 · see citing works
Juan, C. G., García, H. G., Ávila-Navarro, E., Bronchalo, E., Galiano, V., Moreno, Ó., Orozco‐Beltrán, D., & Sabater-Navarro, J. M. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-02030-w · Cited by 36 · see citing works
Ballerstädt, R., Kholodnykh, A. I., Evans, C., Boretsky, A. R., Motamedi, M., Gowda, A., & McNichols, R. J. (2007) · Analytical Chemistry · doi:10.1021/ac0707434 · Cited by 36 · see citing works
Malik, B. H., & Coté, G. L. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3447923 · Cited by 35 · see citing works
Non-invasive monitoring of diabetes through analysis of the exhaled breath condensate (aerosol)
Karyakin, A. A., Никулина, С. В., Vokhmyanina, D. V., Karyakina, E. E., Anaev, E. K., & Чучалин, А. Г. (2017) · Electrochemistry Communications · doi:10.1016/j.elecom.2017.09.005 · Cited by 35 · see citing works
Wood, M. F. G., Côté, D. C., & Vitkin, I. A. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2968198 · Cited by 35 · see citing works
Extended Near-Infrared Optoacoustic Spectrometry for Sensing Physiological Concentrations of Glucose
Ghazaryan, A. A., Ovsepian, S. V., & Ntziachristos, V. (2018) · Frontiers in Endocrinology · doi:10.3389/fendo.2018.00112 · Cited by 34 · see citing works
Hadar, E., Chen, R., Toledano, Y., Tenenbaum-Gavish, K., Atzmon, Y., & Hod, M. (2018) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2018.1463987 · Cited by 33 · see citing works
Kinnunen, M. T., Myllylä, R. A., & Vainio, S. J. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2904957 · Cited by 33 · see citing works
Evaluation of a new noninvasive glucose monitoring device by means of standardized meal experiments
Pfützner, A., Strobl, S., Demircik, F., Redert, L., Pfützner, J., Pfützner, A. H., & Lier, A. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818758769 · Cited by 33 · see citing works
Westphal, P., Kaltenbach, J.-M., & Wicker, K. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.001160 · Cited by 33 · see citing works
Breath Acetone as Biomarker for Lipid Oxidation and Early Ketone Detection
Prabhakar, A., Ashley, Q., Wang, D., Haojiong, Z., Terrera, M., David, J., Xian, X., Francis, T., Tao, N. J., & Forzani, E. (2014) · Global Journal of Obesity Diabetes and Metabolic Syndrome · doi:10.17352/2455-8583.000003 · Cited by 33 · see citing works
Zhang, Y., Wu, G., Wei, H., Guo, Z., Yang, H., He, Y., Xie, S., & Liu, Y. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.000990 · Cited by 32 · see citing works
Singh, S. P., Mukherjee, S., Galindo, L. H., So, P. T. C., Dasari, R. R., Khan, U. Z., Kannan, R., Upendran, A., & Kang, J. W. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1244-y · Cited by 31 · see citing works
Influence of osmolarity on the optical properties of human erythrocytes
Friebel, M. F., Helfmann, J., & Meinke, M. C. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3486542 · Cited by 31 · see citing works
Instrument for near infrared emission spectroscopic probing of human fingertips in vivo
Chaiken, J., Deng, B., Bussjager, R. J., Shaheen, G., Rice, D. A., Stehlik, D., & Fayos, J. (2010) · Review of Scientific Instruments · doi:10.1063/1.3314290 · Cited by 30 · see citing works
Zanon, M., Mueller, M., Zakharov, P., Talary, M. S., Donath, M. Y., Stahel, W. A., & Caduff, A. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817740591 · Cited by 30 · see citing works
Effect on blood glucose monitoring of skin pressure exerted by an optical coherence tomography probe
Sapozhnikova, V. V., Kuranov, R. V., Cicenaite, I., Esenaliev, R. O., & Prough, D. S. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2909671 · Cited by 29 · see citing works
Optical polarimetry for noninvasive glucose sensing enabled by Sagnac interferometry
Winkler, A. M., Bonnema, G. T., & Barton, J. K. (2011) · Applied Optics · doi:10.1364/ao.50.002719 · Cited by 29 · see citing works
Non-Invasive Glucose Monitoring Techniques: A review and current trendsPreprint
Poddar, R., Andrews, J. T., Shukla, P., & Sen, P. (2008) · arXiv (Cornell University) · doi:10.48550/arxiv.0810.5755 · Cited by 28 · see citing works
Liu, G., Huang, K., Jia, Q., Liu, S., Shen, S., Li, J., Dong, E., Lemaillet, P., Allen, D. W., & Xu, R. X. (2018) · Applied Optics · doi:10.1364/ao.57.006772 · Cited by 28 · see citing works
Biomedical Optics in Otorhinolaryngology
Wong, B. J. F., Ilgner, J. F. R., Witjes, M. J. H., de Visscher, S. A. H. J., & Roodenburg, J. L. N. (2016) · Springer eBooks · doi:10.1007/978-1-4939-1758-7 · Cited by 27 · see citing works
New equivalent-electrical circuit model and a practical measurement method for human body impedance
Chinen, K., Kinjo, I., Zamami, A., Irei, K., & Nagayama, K. (2015) · Bio-Medical Materials and Engineering · doi:10.3233/bme-151369 · Cited by 26 · see citing works
Fluorescence quenching of albumin. A spectrofluorimetric experiment
Montero, M. T., Hernández‐Borrell, J., & Estelrich, J. (1990) · Biochemical Education · doi:10.1016/0307-4412(90)90188-t · Cited by 26 · see citing works
Continuous noninvasive glucose monitoring; water as a relevant marker of glucose uptake in vivo
Caduff, A., Ishai, P. B., & Feldman, Y. D. (2019) · Biophysical Reviews · doi:10.1007/s12551-019-00601-7 · Cited by 25 · see citing works
Sun, M., Zhao, X., Yin, H., Wang, Z., Jiang, C., Liu, W., Chen, Z., Yuan, Y., Li, Y., & Wang, C. (2015) · RSC Advances · doi:10.1039/c5ra07084h · Cited by 25 · see citing works
Yuan, Y., Chen, Z., Zhao, X., Sun, M., Li, Y., Wang, Z., & Wang, C. (2017) · Journal of Analytical & Bioanalytical Techniques · doi:10.4172/2155-9872.1000386 · Cited by 25 · see citing works
Saitô, T., Ishikawa, S., Higashiyama, M., Nakamura, T., Rokkaku, K., Hayashi, H., Kusaka, I., Nagasaka, S., & Saito, T. (1999) · Endocrine Journal · doi:10.1507/endocrj.46.75 · Cited by 24 · see citing works
On the suitability of refractometry for the analysis of glucose in blood-derived fluids
Zirk, K., & Pötzschke, H. (2004) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.03.008 · Cited by 24 · see citing works
Wang, S., Sherlock, T., Salazar, B., Sudheendran, N., Manapuram, R. K., Kourentzi, K. D., Ruchhoeft, P., Willson, R. C., & Larin, K. V. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2270008 · Cited by 23 · see citing works
Kirillin, M., Priezzhev, A. V., Kinnunen, M. T., Alarousu, E., Zhao, Z., Hast, J. T., & Myllyl�, R. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.535341 · Cited by 23 · see citing works
Influence of Osmolytes on In Vivo Glucose Monitoring Using Optical Coherence Tomography
Sapozhnikova, V. V., Prough, D. S., Kuranov, R. V., Cicenaite, I., & Esenaliev, R. O. (2006) · Experimental Biology and Medicine · doi:10.1177/153537020623100806 · Cited by 22 · see citing works
Pretto, L. R. D., Yoshimura, T. M., Ribeiro, M. S., & de Freitas, A. Z. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.8.086007 · Cited by 22 · see citing works
Data Processing for Noninvasive Continuous Glucose Monitoring with a Multisensor Device
Mueller, M. C., Talary, M. S., Falco, L., Feo, O. D., Stahel, W. A., & Caduff, A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500324 · Cited by 21 · see citing works
Molar extinction coefficients of some carbohydrates in aqueous solutions
Singh, K., Sandhu, G. K., Lark, B., & Sud, S. (2002) · Pramana · doi:10.1007/s12043-002-0061-0 · Cited by 20 · see citing works
Caduff, A., Zanon, M., Zakharov, P., Mueller, M., Talary, M., Krebs, A., Stahel, W. A., & Donath, M. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817750932 · Cited by 17 · see citing works
Phase contrast coherence microscopy based on transverse scanning
Pircher, M., Baumann, B., Götzinger, E., Sattmann, H., & Hitzenberger, C. K. F. (2009) · Optics Letters · doi:10.1364/ol.34.001750 · Cited by 17 · see citing works
Sbrignadello, S., Tura, A., & Ravazzani, P. (2012) · Journal of Spectroscopy · doi:10.1155/2013/571372 · Cited by 16 · see citing works
Huber, D., Talary, M. S., Dewarrat, F., & Caduff, A. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0229-3 · Cited by 16 · see citing works
Dual-modulation, dual-wavelength, optical polarimetry system for glucose monitoring
Yu, Z. F., Pirnstill, C. W., & Coté, G. L. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.8.087001 · Cited by 16 · see citing works
Tang, W., Yan, W., He, G., Li, G., & Lin, L. (2018) · Infrared Physics & Technology · doi:10.1016/j.infrared.2018.11.018 · Cited by 15 · see citing works
Flagged first, then by citations
3 of the 233 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- [118]Lide D.R. CRC Handbook of Chemistry and Physics 85th ed. CRC Press Boca Raton, FL, USA 2005 Volume 85
Cited by
Sorted by citations
Non-Invasive Blood Glucose Monitoring Technology: A Review
Tang, L., Chang, S. J., Chen, C.-J., & Liu, J.-T. (2020) · Sensors · doi:10.3390/s20236925 · Cited by 481 · see citing works
Kiani, S., Rezaei, P., & Fakhr, M. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3052011 · Cited by 222 · see citing works
Pullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210 · see citing works
“The major problem with non‐invasive optical sensors is the specific measurement of glucose with sufficient analytical quality [109].”
BackgroundGlucose Detection Devices and Methods Based on Metal–Organic Frameworks and Related Materials
Adeel, M., Asif, K., Rahman, M. M., Daniele, S., Canzonieri, V., & Rizzolio, F. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202106023 · Cited by 180 · see citing works
Firouzi, F., Farahani, B., Daneshmand, M., Grise, K., Song, J., Saracco, R., Wang, L. L., Lo, K., Angelov, P. P., Soares, E. A., et al. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2021.3073904 · Cited by 152 · see citing works
Implantable Flexible Sensors for Health Monitoring
Yu, A., Zhu, M., Chen, C., Li, Y., Cui, H., Liu, S., & Zhao, Q. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202302460 · Cited by 138 · see citing works
Shokrekhodaei, M., Cistola, D. P., Roberts, R. C., & Quiñones, S. (2021) · IEEE Access · doi:10.1109/access.2021.3079182 · Cited by 132 · see citing works
Self-citationDixit, K., Fardindoost, S., Ravishankara, A., Tasnim, N., & Hoorfar, M. (2021) · Biosensors · doi:10.3390/bios11120476 · Cited by 129 · see citing works
A Review of Non-Invasive Optical Systems for Continuous Blood Glucose Monitoring
Alsunaidi, B., Althobaiti, M., Tamal, M., Albaker, W. I., & Al-Naib, I. A. I. (2021) · Sensors · doi:10.3390/s21206820 · Cited by 117 · see citing works
Artificial intelligence biosensors for continuous glucose monitoring
Jin, X., Cai, A., Xu, T., & Zhang, X. (2023) · Interdisciplinary materials · doi:10.1002/idm2.12069 · Cited by 121 · see citing works
Detection of breath acetone by semiconductor metal oxide nanostructures-based gas sensors: A review
Ahmadipour, M., Pang, A. L., Ardani, M. R., Pung, S., Ooi, P. C., Hamzah, A. A., Wee, M. F. M. R., Haniff, M. A. S. M., Dee, C. F., Mahmoudi, E., et al. (2022) · Materials Science in Semiconductor Processing · doi:10.1016/j.mssp.2022.106897 · Cited by 108 · see citing works
Wearable Glucose Monitoring and Implantable Drug Delivery Systems for Diabetes Management
Zhang, J., Xu, J., Lim, J., Nolan, J. K., Lee, H., & Lee, C. H. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100194 · Cited by 109 · see citing works
Holzer, R., Bloch, W., & Brinkmann, C. K. (2022) · Sensors · doi:10.3390/s22052030 · Cited by 108 · see citing works
Huang, L. F., Le, T., Huang, K., & Han, G. (2021) · Nature Communications · doi:10.1038/s41467-021-22282-1 · Cited by 101 · see citing works
Hydrogel-based flexible materials for diabetes diagnosis, treatment, and management
Jiang, S., Zhang, Y., Chan, S. Y., Du, Z., Yan, Y., Wang, T., Li, P., & Huang, W. (2021) · npj Flexible Electronics · doi:10.1038/s41528-021-00122-y · Cited by 100 · see citing works
Reddy, V. S., Agarwal, B., Ye, Z., Zhang, C., Roy, K., Chinnappan, A., Narayan, R. J., Ramakrishna, S., & Ghosh, R. (2022) · Nanomaterials · doi:10.3390/nano12071082 · Cited by 97 · see citing works
Non-invasive measurements of blood glucose levels by time-gating mid-infrared optoacoustic signals
Uluç, N., Glasl, S., Gasparin, F., Yuan, T., He, H., Jüstel, D., Pleitez, M. A., & Ntziachristos, V. (2024) · Nature Metabolism · doi:10.1038/s42255-024-01016-9 · Cited by 98 · see citing works
Review of present method of glucose from human blood and body fluids assessment
Fiedorova, K., Augustýnek, M., Kubíček, J., Kudrna, P., & Bibbo, D. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114348 · Cited by 93 · see citing works
Microwave Planar Resonant Solutions for Glucose Concentration Sensing: A Systematic Review
Juan, C. G., Potelon, B., Quendo, C., & Bronchalo, E. (2021) · Applied Sciences · doi:10.3390/app11157018 · Cited by 84 · see citing works
Commercial and Scientific Solutions for Blood Glucose Monitoring—A Review
Xue, Y., Thalmayer, A. S., Zeising, S., Fischer, G., & Lübke, M. (2022) · Sensors · doi:10.3390/s22020425 · Cited by 85 · see citing works
Filippo, D. D., Sunstrum, F. N., Khan, J. U., & Welsh, A. W. (2023) · Sensors · doi:10.3390/s23229130 · Cited by 90 · see citing works
Zhou, C., Meng, F., Chen, K., Yang, X., Wang, T., Sun, P., Liu, F., Yan, X., Shimanoe, K., & Lu, G. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.129912 · Cited by 71 · see citing works
Shang, T., Zhang, J. Y., Thomas, A., Arnold, M. A., Vetter, B., Heinemann, L., & Klonoff, D. C. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211007212 · Cited by 73 · see citing works
Non-Invasive Glucose Measurement Technologies: Recent Advancements and Future Challenges
Jain, P., Joshi, A. M., Mohanty, S. P., & Cenkeramaddi, L. R. (2024) · IEEE Access · doi:10.1109/access.2024.3389819 · Cited by 78 · see citing works
Gupta, S., & Tai, N. (2023) · Journal of the Taiwan Institute of Chemical Engineers · doi:10.1016/j.jtice.2023.104957 · Cited by 69 · see citing works
The Most Common Methods for Breath Acetone Concentration Detection: A Review
Obeidat, Y. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3074610 · Cited by 65 · see citing works
Jin, R., Jiang, Y., Zhao, L., Wang, T., Liu, X., Liu, F., Yan, X., Sun, P., & Lu, G. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.131839 · Cited by 65 · see citing works
Zeynali, M., Alipour, K., Tarvirdizadeh, B., & Ghamari, M. (2025) · Scientific Reports · doi:10.1038/s41598-024-84265-8 · Cited by 65 · see citing works
Thermal Detection of Glucose in Urine Using a Molecularly Imprinted Polymer as a Recognition Element
Caldara, M., Lowdon, J. W., Rogosic, R., Arreguin-Campos, R., Jiménez-Monroy, K. L., Heidt, B., Tschulik, K., Cleij, T. J., Diliën, H., Eersels, K., et al. (2021) · ACS Sensors · doi:10.1021/acssensors.1c02223 · Cited by 63 · see citing works
Susana, E., Ramli, K., Murfi, H., & Apriantoro, N. H. (2022) · Information · doi:10.3390/info13020059 · Cited by 59 · see citing works
Optical glucose biosensor built-in disposable strips and wearable electronic devices
Reda, A., El‐Safty, S. A., Selim, M. M., & Shenashen, M. A. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113237 · Cited by 59 · see citing works
Juan, C. G., Potelon, B., Quendo, C., García, H. G., Ávila-Navarro, E., Bronchalo, E., & Sabater-Navarro, J. M. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3122525 · Cited by 56 · see citing works
Electrically Transduced Gas Sensors Based on Semiconducting Metal Oxide Nanowires
Wang, Y., Duan, L., Deng, Z. Y., & Liao, J. (2020) · Sensors · doi:10.3390/s20236781 · Cited by 53 · see citing works
Noninvasive Diabetes Detection through Human Breath Using TinyML-Powered E-Nose
Gudiño-Ochoa, A., García-Rodríguez, J. A., Ochoa-Ornelas, R., Chávez, J. I. C., & Sánchez-Arias, D. A. (2024) · Sensors · doi:10.3390/s24041294 · Cited by 56 · see citing works
Kandwal, A., Liu, L. W., Deen, M. J., Jasrotia, R., Kanaujia, B. K., & Nie, Z. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3327466 · Cited by 50 · see citing works
Mehmood, S., Ahmad, I., Arif, H., Ammara, U. E., & Majeed, A. (2020) · Applied System Innovation · doi:10.3390/asi3030031 · Cited by 50 · see citing works
Electronic nose based on metal oxide semiconductor sensors for medical diagnosis
Zhang, Z., Zheng, Z., He, X., Liu, K., Debliquy, M., Zhou, Y., & Zhang, C. (2024) · Progress in Natural Science Materials International · doi:10.1016/j.pnsc.2024.01.018 · Cited by 46 · see citing works
Low dimensional materials for glucose sensing
Xu, L., Zhang, X., Wang, Z., Haidry, A. A., Yao, Z., Haque, E., Wang, Y., Li, G., Daeneke, T., McConville, C. F., et al. (2021) · Nanoscale · doi:10.1039/d1nr02529e · Cited by 44 · see citing works
Glucose Level Sensing Using Single Asymmetric Split Ring Resonator
Saleh, G., Ateeq, I. S., & Al-Naib, I. A. I. (2021) · Sensors · doi:10.3390/s21092945 · Cited by 44 · see citing works
Gopal, T. S., Alzahrani, K. E., Assaifan, A. K., Albrithen, H., Alodhayb, A. N., Muthuramamoorthy, M., Pandiaraj, S., & Grace, A. N. (2022) · Scientific Reports · doi:10.1038/s41598-022-24700-w · Cited by 43 · see citing works
Recent Progress and Perspectives on Non-Invasive Glucose Sensors
Davison, N. B., Gaffney, C. J., Kerns, J. G., & Zhuang, Q. (2022) · Diabetology · doi:10.3390/diabetology3010005 · Cited by 40 · see citing works
Leon, M. J. B. M., Abedin, S., & Kabir, M. A. (2020) · Sensors International · doi:10.1016/j.sintl.2020.100061 · Cited by 40 · see citing works
Artificial intelligence powered glucose monitoring and controlling system: Pumping module
Medanki, S., Dommati, N., Bodapati, H. H., Katru, V. N. S. K., Moses, G., Komaraju, A., Donepudi, N. S., Yalamanchili, D., Sateesh, J., & Turimerla, P. (2024) · World Journal of Experimental Medicine · doi:10.5493/wjem.v14.i1.87916 · Cited by 39 · see citing works
Non-invasive blood glucose monitoring technology in diabetes management: review
Moses, J. C., Adibi, S., Wickramasinghe, N. S., Nguyen, L., Angelova, M. N., & Islam, S. M. S. (2024) · mHealth · doi:10.21037/mhealth-23-9 · Cited by 41 · see citing works
Kaysir, M. R., Song, J., Rassel, S., Aloraynan, A., & Ban, D. (2023) · Biosensors · doi:10.3390/bios13070716 · Cited by 38 · see citing works
Noninvasive blood glucose monitoring using a dual band microwave sensor with machine learning
Farouk, M., El-Hameed, A. S. A., Eldamak, A. R. A. M. A., & Elsheakh, D. N. (2025) · Scientific Reports · doi:10.1038/s41598-025-94367-6 · Cited by 36 · see citing works
Swargiary, K., Thaneerat, S., Kongsawang, N., Pathak, A. K., & Viphavakit, C. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.117061 · Cited by 34 · see citing works
Todaro, B., Begarani, F., Sartori, F., & Luin, S. (2022) · Frontiers in Chemistry · doi:10.3389/fchem.2022.994272 · Cited by 35 · see citing works
Sun, Y., Cano-Garcia, H., Kallos, E., O’Brien, F., Akintonde, A., Motei, D. E., Ancu, O., Mackenzie, R., & Kosmas, P. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3293248 · Cited by 33 · see citing works
Elagan, S. K., Abdelwahab, S. F., Zanaty, E. A., Alkinani, M. H., Alotaibi, H., & Zanaty, M. E. A. (2021) · Results in Physics · doi:10.1016/j.rinp.2021.103910 · Cited by 31 · see citing works
Sanai, F., Sahid, A. S., Huvanandana, J., Spoa, S., Boyle, L. H., Hribar, J., Wang, D. T.-Y., Kwan, B., Colagiuri, S., Cox, S. J., et al. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211054110 · Cited by 30 · see citing works
Advancements in Glucose Monitoring: From Traditional Methods to Wearable Sensors
Dey, K., Santra, T. S., & Tseng, F. (2025) · Applied Sciences · doi:10.3390/app15052523 · Cited by 27 · see citing works
Roblyer, D. M. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.10.102703 · Cited by 29 · see citing works
Colorimetric Nanoplasmonics to Spot Hyperglycemia From Saliva
Donati, P. P., Pomili, T., Boselli, L., & Pompa, P. P. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.601216 · Cited by 27 · see citing works
Althobaiti, M., & Al-Naib, I. A. I. (2021) · IEEE photonics journal · doi:10.1109/jphot.2021.3079408 · Cited by 27 · see citing works
Terahertz Asymmetric S-Shaped Complementary Metasurface Biosensor for Glucose Concentration
Al-Naib, I. A. I. (2022) · Biosensors · doi:10.3390/bios12080609 · Cited by 27 · see citing works
Sohrabi, H., Dezhakam, E., Nozohouri, E., Majidi, M. R., Orooji, Y., Yoon, Y., & Khataee, A. (2022) · Chemosphere · doi:10.1016/j.chemosphere.2022.136633 · Cited by 27 · see citing works
A Noninvasive Blood Glucose Estimation System Using Dual-Channel PPGs and Pulse-Arrival Velocity
Lee, P., Wang, K., & Hsiao, C. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3306343 · Cited by 26 · see citing works
Conductive and Eco-friendly Biomaterials-based Hydrogels for Noninvasive Epidermal Sensors: A Review
Zhang, Y., Tang, Q., Zhou, J., Zhao, C., Li, J., & Wang, H. (2023) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.3c01003 · Cited by 26 · see citing works
Karami, P., & Parandin, F. (2025) · Results in Engineering · doi:10.1016/j.rineng.2025.106416 · Cited by 24 · see citing works
Noninvasive Glucose Sensing In Vivo
Leung, H. M. C., Forlenza, G. P., Prioleau, T., & Zhou, X. (2023) · Sensors · doi:10.3390/s23167057 · Cited by 28 · see citing works
On the use of fiber lasers in non-invasive blood glucose monitoring
Peng, X., Yan, Y., & Liu, H. (2022) · Optical Fiber Technology · doi:10.1016/j.yofte.2022.102822 · Cited by 23 · see citing works
On the Selectivity of Planar Microwave Glucose Sensors with Multicomponent Solutions
Juan, C. G., Bronchalo, E., Potelon, B., Quendo, C., Muñoz, V. F., Vicente, J. M. F., & Sabater-Navarro, J. M. (2022) · Electronics · doi:10.3390/electronics12010191 · Cited by 23 · see citing works
Zhang, C., Wei, C., Chen, D., Xu, Z., & Huang, X. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.133630 · Cited by 23 · see citing works
Cheon, S.-I., Kweon, S.-J., Kim, Y.-I., Koo, J., Ha, S., & Je, M. (2022) · Sensors · doi:10.3390/s22041563 · Cited by 22 · see citing works
Nano/micro-scaled materials based optical biosensing of glucose
Kumar, R., & Chauhan, S. (2021) · Ceramics International · doi:10.1016/j.ceramint.2021.10.170 · Cited by 21 · see citing works
Sensing Glucose Concentration Using Symmetric Metasurfaces under Oblique Incident Terahertz Waves
Al-Naib, I. A. I. (2021) · Crystals · doi:10.3390/cryst11121578 · Cited by 21 · see citing works
Cano-Garcia, H., Kshirsagar, R., Pricci, R. L., Teyeb, A., O’Brien, F., Saha, S. C., Kosmas, P., & Kallos, E. (2021) · Sensors · doi:10.3390/s21093275 · Cited by 19 · see citing works
Gouzi, F., Ayache, D., Hédon, C., Molinari, N., & Vicet, A. (2021) · Journal of Breath Research · doi:10.1088/1752-7163/ac356d · Cited by 19 · see citing works
Gallium ions induced in-situ MOF-derived hierarchical porous Co3O4 for ultra-high acetone response
Guo, R., Deng, Y., Jia, Y., Shi, C., Zhang, W., Zhou, Y. T., & Hou, X. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.134832 · Cited by 18 · see citing works
Continuous glucose monitoring using wearable non-enzymatic sensors in a physiological environment
Tehrani, M. A., Ahmadi, S. H., Alimohammadi, S., Sasanpour, P., Batvani, N., Kazemi, S. H., & Kiani, M. A. (2024) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2024.100482 · Cited by 17 · see citing works
Machine Learning Methods of Regression for Plasmonic Nanoantenna Glucose Sensing
Corcione, E., Pfezer, D., Hentschel, M., Giessen, H. W., & Tarín, C. (2021) · Sensors · doi:10.3390/s22010007 · Cited by 16 · see citing works
A glucose-responsive microgel-based soft etalon as an epidermal glucose colorimetric sensor
Nam, S., Kim, H., Lee, S. M., Durukan, M. B., Ünalan, H. E., & Lee, H. J. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.134554 · Cited by 16 · see citing works
Zheng, Z., Qiu, S., & Wei, Z. (2022) · Chemosensors · doi:10.3390/chemosensors10080332 · Cited by 15 · see citing works
Li, X., Hu, X., Li, A., Kometani, R., Yamada, I., Sashida, K., Noma, M., Nakanishi, K., Fukuda, Y., Takemori, T., et al. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.114070 · Cited by 15 · see citing works
Liu, K., Zhu, T., Yao, L., Zhang, Z., Li, H., Ye, J., & Li, P. (2021) · Biomedical Optics Express · doi:10.1364/boe.430104 · Cited by 15 · see citing works
Hossain, S., Haque, C. A., & Kim, K. (2021) · Applied Sciences · doi:10.3390/app11156867 · Cited by 15 · see citing works
Ghosh, N., & Verma, S. (2024) · Current Medical Research and Opinion · doi:10.1080/03007995.2024.2422005 · Cited by 18 · see citing works
Marzouk, H. M., El-Hameed, A. S. A., Allam, A., Pokharel, R. K., & Abdel-Rahman, A. B. (2023) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.3903 · Cited by 14 · see citing works
Gao, M., Guo, D., Wang, J., Tan, Y., Liu, K., Gao, L., Zhang, Y., Ding, Z., Gu, Y., & Li, P. (2024) · Biomedical Optics Express · doi:10.1364/boe.506092 · Cited by 14 · see citing works
Li, D., Zhang, Y., Sun, F., Félidj, N., Gagey‐Eilstein, N., Lamouri, A., Hémadi, M., Nizard, P., Luo, Y., & Mangeney, C. (2024) · ACS Applied Bio Materials · doi:10.1021/acsabm.3c01250 · Cited by 14 · see citing works
Dielectric Models of Blood-Glucose Solutions: A Systematic Literature Review
Dima, R., Costanzo, S., & Solimene, R. (2024) · IEEE Access · doi:10.1109/access.2024.3479099 · Cited by 14 · see citing works
Liu, J., Chu, J., Xu, J., Zhang, Z., & Wang, S. (2024) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2024.125584 · Cited by 14 · see citing works
Xu, C., Rassel, S., Zhang, S. L., Aloraynan, A., & Ban, D. (2020) · Biomedical Optics Express · doi:10.1364/boe.413086 · Cited by 14 · see citing works
PPG-based glucose sensors: a review
Jiang, H., Yao, T., & Ding, C. (2025) · Artificial Intelligence Review · doi:10.1007/s10462-025-11379-4 · Cited by 15 · see citing works
Illuminating the Tiny World: A Navigation Guide for Proper Raman Studies on Microorganisms
Frempong, S. B., Salbreiter, M., Mostafapour, S., Pistiki, A. C., Bocklitz, T. W., Rösch, P., & Popp, J. (2024) · Molecules · doi:10.3390/molecules29051077 · Cited by 13 · see citing works
Evaluation of microwave square ring metamaterial-based resonator for glucose detection
Kamal, M. H. M., Qureshi, S. A., Abidin, Z. Z., Majid, H. A., & See, C. H. (2024) · Journal of Engineering and Applied Science · doi:10.1186/s44147-024-00366-1 · Cited by 13 · see citing works
López-Peña, G., Ortiz-Mansilla, E., Arranz, A., Bogdan, N., Manso‐Silván, M., & Rodríguez, E. M. (2024) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2024.113934 · Cited by 12 · see citing works
Du, K., Zhao, M., Hua, Y., Wei, S., Wang, T., Qu, G., & Cai, H. (2025) · Results in Physics · doi:10.1016/j.rinp.2025.108272 · Cited by 13 · see citing works
A solid-state glucose sensor based on Cu and Fe–doped carbon nitride
Dante, R. C., Trakulmututa, J., Smith, S. M., Sirisit, N., Martín‐Ramos, P., Chamorro‐Posada, P., Rutto, D., & Dante, D. G. (2020) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2020.124023 · Cited by 13 · see citing works
Estimation of the Differential Pathlength Factor for Human Skin Using Monte Carlo Simulations
Althobaiti, M. (2023) · Diagnostics · doi:10.3390/diagnostics13020309 · Cited by 12 · see citing works
Noninvasive blood glucose sensing by secondary speckle pattern artificial intelligence analyses
Pal, D., Kumar, A., Avraham, N., Eisenbach, Y., Beiderman, Y., Agdarov, S., Beiderman, Y., & Zalevsky, Z. (2023) · Journal of Biomedical Optics · doi:10.1117/1.jbo.28.8.087001 · Cited by 12 · see citing works
Acetone sensors for non-invasive diagnosis of diabetes based on metal–oxide–semiconductor materials
Li, Y., Zhang, M., & Zhang, H. (2020) · Chinese Physics B · doi:10.1088/1674-1056/aba60b · Cited by 12 · see citing works
Afshari, N., Hashemi, S. M., & Geran, F. (2023) · IET Microwaves Antennas & Propagation · doi:10.1049/mia2.12404 · Cited by 11 · see citing works
Glucose Concentration Monitoring Using Microstrip Spurline Sensor
Harnsoongnoen, S., & Buranrat, B. (2023) · Measurement Science Review · doi:10.2478/msr-2023-0022 · Cited by 11 · see citing works
Lee, Y. S., Son, M., Zhbanov, A. I., Jung, Y., Jung, M. H., Eom, K., Nam, S. H., Park, J., & Yang, S. H. (2020) · Sensors · doi:10.3390/s20216231 · Cited by 11 · see citing works
In Vitro System for Evaluation of Biosensors in Controlled Dynamic Environmental Conditions
Ko, B. S., Zavareh, A. T., & McShane, M. J. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3334366 · Cited by 10 · see citing works
Optical sensor to improve the accuracy of non-invasive blood sugar monitoring
Zilgarayeva, A., Смайлов, Н., Pavlov, S. V., Mirzakulova, S., Alimova, M., Kulambayev, B., & Nurpeissova, D. (2024) · Indonesian Journal of Electrical Engineering and Computer Science · doi:10.11591/ijeecs.v34.i3.pp1489-1498 · Cited by 9 · see citing works
Gold Nanoparticles in Porous Silicon Nanotubes for Glucose Detection
González-Rodríguez, R., Hathaway, E., Coffer, J. L., del Castillo, R. M., Lin, Y., & Cui, J. (2024) · Chemosensors · doi:10.3390/chemosensors12040063 · Cited by 8 · see citing works
A’dawiah, R., Yap, A. A. M., Rajarahm, P., Zheng, S., Zhang, R., Yi, Q., Dinish, U. S., Xu, W., Balasundaram, G., Olivo, M., et al. (2025) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2025.2485280 · Cited by 8 · see citing works
- Authors
- Shokrekhodaei, M., & Quinones, S.
- Affiliations
- The University of Texas at El Paso (US)
- Department of Metallurgical, Materials and Biomedical Engineering, The University of Texas at El Paso, El Paso, TX 79968, USA
- Corresponding author
- Shokrekhodaei, Maryamsadat
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-02-25
- Volume
- 20
- Issue
- 5
- Pages
- 1251
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC7085605
- OpenAlex
- W3007868482
- Cited by
- 221
- References
- 233
- Citations by year
- 2026: 23 · 2025: 31 · 2024: 36 · 2023: 38 · 2022: 38 · 2021: 41 · 2020: 14
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- University of Texas at El Paso
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- non-invasive glucose monitoring, diabetes mellitus, continuous glucose monitoring, optical glucose sensor, clinical accuracy
- MeSH terms
- Acetone, Blood Glucose, Breath Tests, Electricity, Humans, Biosensing Techniques, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review