CoChat

Glycated Hemoglobin Assessment in Clinical Practice: Comparison of the A1cNow™ Point-of-Care Device with Central Laboratory Testing (GOAL A1C Study)

Open access
Kennedy, Laurence, Herman, William H. · 2005 · Diabetes Technology & Therapeutics
Cited by 39

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The Glycemic Optimization with Algorithms and Labs At Po1nt of Care (GOAL A1C) Study assessed the effect of titration monitoring strategies and methods of A1C testing on glycemic control in patients with type 2 diabetes failing oral therapy and beginning basal insulin glargine. The availability of both point-of-care (POC) and central laboratory A1C values provided an opportunity to evaluate correlation and statistical agreement between these methods of testing. This analysis forms the basis of the current report. METHODS: This is a 24-week, randomized, four-arm, open-label study conducted in 7,758 subjects enrolled at 2,130 sites. At baseline, patients had A1C measurements both by POC testing using the A1cNow device (Metrika, Inc., Sunnyvale, CA), which applies an immunoassay method, and by central laboratory analysis using ion exchange high-performance liquid chromatography. These measures were compared statistically. RESULTS: An r value of 0.72 was calculated for POC and laboratory A1C assessments. Although the mean POC A1C values were in agreement with the central laboratory values, there was a large range in individual POC A1C values. CONCLUSIONS: POC testing of A1C in predominantly primary care settings using the A1cNow device was correlated with central laboratory results. The correlation was less than expected based on each method's reproducibility data. Although there was agreement between the average POC A1C values and the corresponding central laboratory values, the dispersion of individual POC A1C values was large. Thus, we conclude that these two methods of A1C testing should not be used interchangeably.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2005.7.907

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 39

Metadata

Authors
Kennedy, L., & Herman, W. H.
Venue
Diabetes Technology & Therapeutics
Published
2005-12
Volume
7
Issue
6
Pages
907-912
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2071023674
Cited by
39
References
4
FWCI
2.01
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Glycated Hemoglobin Assessment in Clinical Practice: Comparison of the A1cNow™ Point-of-Care Device with Central Laboratory Testing (GOAL A1C Study). https://app.cochat.ai/papers/10.1089/dia.2005.7.907
The paper
Kennedy, L., & Herman, W. H. (2005). Glycated Hemoglobin Assessment in Clinical Practice: Comparison of the A1cNow™ Point-of-Care Device with Central Laboratory Testing (GOAL A1C Study). Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2005.7.907

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.