Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 297

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Sensor-Augmented Insulin Pump Therapy: Results of the First Randomized Treat-to-Target Study

Hirsch, Irl B., Abelseth, Jill, Bode, Bruce W., Fischer, Jerome S., Kaufman, Francine R., Mastrototaro, John, Parkin, Christopher G., Wolpert, Howard A., Buckingham, Bruce A. · 2008 · Diabetes Technology & Therapeutics

Abstract

BACKGROUND: The objective of the study was to evaluate the clinical effectiveness and safety of a device that combines an insulin pump with real-time continuous glucose monitoring (CGM), compared to using an insulin pump with standard blood glucose monitoring systems. METHODS: This 6-month, randomized, multicenter, treat-to-target study enrolled 146 subjects treated with continuous subcutaneous insulin infusion between the ages of 12 and 72 years with type 1 diabetes and initial A1C levels of >or=7.5%. Subjects were randomized to pump therapy with real-time CGM (sensor group [SG]) or to pump therapy and self-monitoring of blood glucose only (control group [CG]). Clinical effectiveness and safety were evaluated. RESULTS: A1C levels decreased (P<0.001) from baseline (8.44+/-0.70%) in both groups (SG, -0.71+/-0.71%; CG, -0.56+/-0.072%); however, between-group differences did not achieve significance. SG subjects showed no change in mean hypoglycemia area under the curve (AUC), whereas CG subjects showed an increase (P=0.001) in hypoglycemia AUC during the blinded periods of the study. The between-group difference in hypoglycemia AUC was significant (P<0.0002). Greater than 60% sensor utilization was associated with A1C reduction (P=0.0456). Fourteen severe hypoglycemic events occurred (11 in the SG group and three in the CG group, P=0.04). CONCLUSIONS: A1C reduction was no different between the two groups. Subjects in the CG group had increased hypoglycemia AUC and number of events during blinded CGM use; however, there was no increase in hypoglycemia AUC or number of events in the SG group. Subjects with greater sensor utilization showed a greater improvement in A1C levels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2008.0068

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 297

Metadata

Authors
Hirsch, I. B., Abelseth, J., Bode, B. W., Fischer, J. S., Kaufman, F. R., Mastrototaro, J., Parkin, C. G., Wolpert, H. A., & Buckingham, B. A.
Venue
Diabetes Technology & Therapeutics
Published
2008-10
Volume
10
Issue
5
Pages
377-383
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2126938133
Cited by
297
References
14
FWCI
23.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.