Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 310

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Interpretation of Continuous Glucose Monitoring Data: Glycemic Variability and Quality of Glycemic Control

Rodbard, David · 2009 · Diabetes Technology & Therapeutics

Abstract

There are a large number of measures of glycemic variability, including standard deviation (SD), percentage coefficient of variation (%CV), interquartile range (IQR), mean amplitude of glucose excursion (MAGE), mean of daily differences (MODD), and continuous overlapping net glycemic action over an n-hour period (CONGA(n)). These are all highly correlated with the overall or "total" SD, SD(T). SD(T) is composed of several components corresponding to within-day variability, between-day variability (between daily means and between days-within specified time points), and the interaction of these sources of variability. We identify several subtypes of SD; each is highly correlated with SD(T). Variability may also depend on time of day. Numerous measures of quality of glycemic control have been proposed, including a weighted average of glucose values (M)(e.g., M(100) is M at 100 mg/dL), a measure of quality of glycemic control based on mean and SD (J), the Glycemic Risk Assessment Diabetes Equation (GRADE), the Index of Glycemic Control (IGC), the High Blood Glucose Index (HBGI), the Low Blood Glucose Index (LBGI), the Average Daily Risk Range (ADRR), and percentage of glucose values within specified ranges. These methods usually but not always give consistent results: they can differ widely in terms of their ability to detect responses to therapeutic interventions. Based on review of the advantages and limitations of these measures and on extensive experience in the application of these methods, we outline a systematic approach to the interpretation of continuous glucose monitoring data for use by clinical researchers and clinicians to evaluate the quality of glycemic control, glucose variability including within- and between-day variability, the day-to-day stability of glycemic patterns, and changes in response to therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2008.0132

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 310

Metadata

Authors
Rodbard, D.
Venue
Diabetes Technology & Therapeutics
Published
2009-06-02
Volume
11
Issue
S1
Pages
S-55-S-67
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2046262211
Cited by
310
References
24
FWCI
11.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Interpretation of Continuous Glucose Monitoring Data: Glycemic Variability and Quality of Glycemic Control. https://app.cochat.ai/papers/10.1089/dia.2008.0132
The paper
Rodbard, D. (2009). Interpretation of Continuous Glucose Monitoring Data: Glycemic Variability and Quality of Glycemic Control. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2008.0132

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.