Continuous Glucose Monitoring in Subjects After Simultaneous Pancreas-Kidney and Kidney-Alone Transplantation
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Simultaneous pancreas-kidney (SPK) transplantation is an important replacement therapy for individuals with diabetes and end-stage renal disease. Kidney-alone (KA) transplantation is associated with a high incidence of post-transplant diabetes. METHODS: This was a cross-sectional study. We studied 48-h glucose concentrations in eight subjects with type 1 diabetes mellitus after SPK transplantation, six subjects post-KA transplantation, and nine healthy controls using the CGMS (Medtronic Minimed, Northridge, CA) continuous glucose monitoring system. RESULTS: The 48-h mean glucose concentration was 101 +/- 7 mg/dL in the SPK subjects, 105 +/- 12 mg/dL in the KA subjects, and 99 +/- 7 mg/dL in the healthy controls. The glycemic excursions were higher in the KA group compared to the SPK cohort and healthy controls (P < 0.0001). No differences in the incidence of hypoglycemia were detected among the three groups. Significant postprandial hyperglycemia was uncovered in four of the six KA subjects. CONCLUSIONS: SPK transplantation is very effective at normalizing glycemic excursions. Unsuspected hyperglycemia was identified in the KA group. The CGMS was a useful ambulatory tool to study glucose profiles in the post-transplant period and may help uncover hyperglycemia undetected by routine laboratory testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Association, A. D. (2001) · Diabetes Care · doi:10.2337/diacare.24.4.775 · Cited by 464
Amiel, S. A., Tamborlane, W. V., Simonson, D. C., & Sherwin, R. S. (1987) · New England Journal of Medicine · doi:10.1056/nejm198705283162205 · Cited by 309 · cited 1×
“The ability to perceive hypoglycemia is also compromised, increasing the risk related to it.(12) Successful whole-pancreas transplantation improves glucagon and epinephrine responses to hypoglycemia.”
Barrou, Z., Seaquist, E. R., & Robertson, R. P. (1994) · Diabetes · doi:10.2337/diab.43.5.661 · Cited by 64 · cited 3×
“Although significant improvements in counterregulatory responses have been shown in previous studies, the responses are not as robust as in the healthy state.(13,14) The systemic venous drainage of the pancreas graft as opposed to portal delivery of insulin results in peripheral hyperinsulinemia, suggesting the risk f…”
Paty, B. W., Lanz, K., Kendall, D. M., Sutherland, D. E. R., & Paul Robertson, R. (2001) · Transplantation · doi:10.1097/00007890-200109270-00021 · Cited by 53 · cited 1×
“A study examining hypoglycemia counterregulatory response in long-term post-pancreas transplant individuals (in the range of 5–19 years post-transplantation) revealed adequate increase in plasma glucagon in response to hypoglycemia but suboptimal epinephrine response compared with normal individuals.(24) Redmon et al.”
Cited by
Vantyghem, M.-C., Raverdy, V., Balavoine, A.-S., Defrance, F., Caiazzo, R., Arnalsteen, L., Gmyr, V., Hazzan, M., Noël, C., Kerr-Conte, J., et al. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-2115 · Cited by 103
Meyer, G., Hackemann, A., Reusch, J., & Badenhoop, K. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0158 · Cited by 50
Idrees, T., Castro-Revoredo, I. A., Oh, H. D., Gavaller, M. D., Zabala, Z., Moreno, E., Moazzami, B., Galindo, R. J., Vellanki, P., Cabb, E., et al. (2024) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2024.01.031 · Cited by 22
Metadata
- Authors
- Rodríguez, L. M., Knight, R. J., & Heptulla, R. A.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2010-05
- Volume
- 12
- Issue
- 5
- Pages
- 347-351
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2074894769
- Cited by
- 35
- References
- 4
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.