Point Accuracy of Interstitial Continuous Glucose Monitoring During Exercise in Type 1 Diabetes
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Previous studies of aerobic exercise have found lower sensor accuracy during exercise. Whether or not resistance exercise would also be associated with lower sensor accuracy has not yet been examined. This study sought to investigate the accuracy of continuous glucose monitoring sensor values at rest, during aerobic exercise, and during resistance exercise. SUBJECTS AND METHODS: Twelve individuals with type 1 diabetes performed 45 min of aerobic exercise, resistance exercise, or no exercise/rest followed by 60 min of recovery while monitored by continuous glucose monitoring systems. RESULTS: Sensors underestimated plasma glucose to the greatest extent during rest (-1.29 ± 1.39 mmol/L, P<0.001) and resistance exercise (-0.71 ± 1.35 mmol/L, P<0.001) and least during aerobic exercise (-0.11 ± 1.71 mmol/L, P=0.416). CONCLUSIONS: Optimal accuracy observed with aerobic exercise might arise from augmented blood flow better equilibrating plasma and interstitial fluid or from the combination of systematic sensor underestimation and sensor lag time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Standards of medical care in diabetes—2011
American Diabetes Association (2011) · Diabetes Care · doi:10.2337/dc11-s011 · Cited by 2,880
Cited by
Physical activity/exercise and diabetes: A position statement of the American Diabetes Association
Colberg, S. R., Sigal, R. J., Yardley, J. E., Riddell, M. C., Dunstan, D. W., Dempsey, P. C., Horton, E. S., Castorino, K., & Tate, D. F. (2016) · Diabetes Care · doi:10.2337/dc16-1728 · Cited by 2,991
Self-citationExercise management in type 1 diabetes: a consensus statement
Riddell, M. C., Gallen, I. W., Smart, C. E., Taplin, C. E., Adolfsson, P., Lumb, A. N., Kowalski, A., Rabasa-Lhoret, R., McCrimmon, R. J., Hume, C., et al. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30014-1 · Cited by 903
Self-citationChetty, T., Shetty, V., Fournier, P. A., Adolfsson, P., Jones, T. W., & Davis, E. A. (2019) · Frontiers in Endocrinology · doi:10.3389/fendo.2019.00326 · Cited by 69
Metadata
- Authors
- Yardley, J. E., Sigal, R. J., Kenny, G. P., Riddell, M. C., Lovblom, L. E., & Perkins, B. A.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2013-01
- Volume
- 15
- Issue
- 1
- Pages
- 46-49
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2032320840
- Cited by
- 58
- References
- 2
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Point Accuracy of Interstitial Continuous Glucose Monitoring During Exercise in Type 1 Diabetes. https://app.cochat.ai/papers/10.1089/dia.2012.0182
- The paper
- Yardley, J. E., Sigal, R. J., Kenny, G. P., Riddell, M. C., Lovblom, L. E., & Perkins, B. A. (2013). Point Accuracy of Interstitial Continuous Glucose Monitoring During Exercise in Type 1 Diabetes. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2012.0182
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.