Family Perceptions of Insulin Pump Adverse Events in Children and Adolescents

Wheeler, Benjamin J., Donaghue, Kim C., Heels, Kristine, Ambler, Geoffrey R.·2014·Diabetes Technology & Therapeutics

Abstract

Background: Insulin pumps (for continuous subcutaneous insulin infusion [CSII]) are used widely in type 1 diabetes mellitus. Although there has been considerable study of outcomes, there are few recent data on CSII-associated adverse events and no data on family perceptions of adverse events and their confidence in dealing with them. Subjects and Methods: We approached all families of children and adolescents ≤19 years of age on CSII attending the diabetes clinic over a 16-week clinic cycle. Participants completed a retrospective questionnaire examining issues over the previous 12 months. Data on pump adverse events as well as answers to questions pertaining to education and confidence were collected. Results: Our survey received a response rate of 99%, with 235 of the 238 families approached participating. In the preceding 12 months, 104 of 230 (45%) had reported at least one pump-related adverse event (either mechanical or set-related), with an associated 52 of 229 (23%) resulting in pump replacement. This equated to a minimum incidence density of 53 adverse events/100 person-years. Additionally, 18 of 230 (8%) reported a hospital admission or emergency department attendance as a consequence. Pump malfunction and infusion set/site failures were the most common events reported, with one or more events in 58 of 104 (56%) and 47 of 104 (45%), respectively. Adverse events, excluding set/site failures, were associated with older age (13.1±3.4 years vs. 11.9±4 years; P =0.02). Conclusions: This is the first study to look at family perceptions of adverse events while using modern CSII. It highlights a high self-reported rate of CSII-related adverse events, pump replacement, and subsequent presentation to the hospital. Potential areas for additional targeted education are identified. Further prospective study examining pump adverse event characteristics and incidence is warranted.

Integrity signals

Registry

Crossref · 10.1089/dia.2013.0315

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Wheeler, B. J., Donaghue, K. C., Heels, K., & Ambler, G. R.
Affiliations
The Institute of Endocrinology and Diabetes
Venue
Diabetes Technology & Therapeutics
Published
2014-04
Volume
16
Issue
4
Pages
204-207
ISSN
  • 1520-9156
  • 1557-8593
Cited by
27
References
2
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review