Insulin Pump and Continuous Glucose Monitor Initiation in Hospitalized Patients with Type 2 Diabetes Mellitus
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Insulin pumps and continuous glucose monitoring (CGM) are commonly used by patients with diabetes mellitus in the outpatient setting. The efficacy and safety of initiating inpatient insulin pumps and CGM in the nonintensive care unit setting is unknown. MATERIALS AND METHODS: In a prospective pilot study, inpatients with type 2 diabetes were randomized to receive standard subcutaneous basal-bolus insulin and blinded CGM (group 1, n = 5), insulin pump and blinded CGM (group 2, n = 6), or insulin pump and nonblinded CGM (group 3, n = 5). Feasibility, glycemic control, and patient satisfaction were evaluated among groups. RESULTS: = 0.05). CGM detected 19 hypoglycemic episodes (glucose <70 mg/dL) among all treatment groups, compared with 12 episodes detected by capillary testing, although not statistically significant. No significant differences were found for the total daily dose of insulin or percentage of time spent below target glucose range (<90 mg/dL), in target glucose range (90-180 mg/dL), or above target glucose range (>180 mg/dL). On the Diabetes Treatment Satisfaction Questionnaire-Change, group 3 reported increased hyperglycemia and decreased hypoglycemia frequency compared with the other two groups, although the differences did not reach statistical significance. CONCLUSIONS: Insulin pump and CGM initiation are feasible during hospitalization, although they are labor intensive. Although insulin pump initiation may not lead to improved glycemic control, there is a trend toward CGM detecting a greater number of hypoglycemic episodes. Larger studies are needed to determine whether use of this technology can lower inpatient morbidity and mortality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Capes, S. E., Hunt, D., Malmberg, K., & Gerstein, H. C. (2000) · The Lancet · doi:10.1016/s0140-6736(99)08415-9 · Cited by 2,187
Management of diabetes and hyperglycemia in hospitals.
Clement, S., Braithwaite, S. S., Magee, M. F., Ahmann, A., Smith, E. P., Schafer, R. G., Hirsch, I. B., & on behalf of the Diabetes in Hospitals Writing Committee (2004) · Diabetes Care · doi:10.2337/diacare.27.2.553 · Cited by 1,266 · cited 1×
“These findings have led to recommendations for more frequent inpatient glycemic monitoring, especially in patients at high risk for recurrent hypoglycemia.(5) In the nonintensive care unit (non-ICU), patients with diabetes are typically administered subcutaneous long-acting basal and rapid-acting insulin analogues, ba…”
BackgroundStahn, A., Pistrosch, F., Ganz, X., Teige, M., Koehler, C., Bornstein, S., & Hanefeld, M. (2014) · Diabetes Care · doi:10.2337/dc13-0600 · Cited by 173
Bellido, V., Suarez, L., Rodriguez, M. G., Sanchez, C., Dieguez, M., Riestra, M., Casal, F., Delgado, E., Menendez, E., & Umpierrez, G. E. (2015) · Diabetes Care · doi:10.2337/dc15-0160 · Cited by 118 · cited 1×
“glycemic targets.(19,20) Numerous publications, primarily reviews and retrospective studies, have evaluated the continued use of outpatient insulin pumps during an acute care hospitalization.”
Background
Cited by
Korytkowski, M. T., Muniyappa, R., Antinori-Lent, K., Donihi, A. C., Drincic, A. T., Hirsch, I. B., Luger, A., McDonnell, M. E., Murad, M. H., Nielsen, C., et al. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac278 · Cited by 315
Seisa, M. O., Saadi, S., Nayfeh, T., Muthusamy, K., Shah, S. H., Firwana, M., Hasan, B., Jawaid, T., Abd-Rabu, R., Korytkowski, M. T., et al. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac277 · Cited by 65
Diabetes technology in the inpatient setting for management of hyperglycemia
Davis, G. M., Galindo, R. J., Migdal, A. L., & Umpierrez, G. E. (2020) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.11.002 · Cited by 62
Carlson, A. L., Huyett, L. M., Jantz, J., Chang, A., Vienneau, T., & Ly, T. T. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.108735 · Cited by 20
Metadata
- Authors
- Levitt, D. L., Spanakis, E. K., Ryan, K. A., & Silver, K. D.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2018-01
- Volume
- 20
- Issue
- 1
- Pages
- 32-38
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2781585919
- Cited by
- 26
- References
- 4
- FWCI
- 2.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Insulin Pump and Continuous Glucose Monitor Initiation in Hospitalized Patients with Type 2 Diabetes Mellitus. https://app.cochat.ai/papers/10.1089/dia.2017.0250
- The paper
- Levitt, D. L., Spanakis, E. K., Ryan, K. A., & Silver, K. D. (2018). Insulin Pump and Continuous Glucose Monitor Initiation in Hospitalized Patients with Type 2 Diabetes Mellitus. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2017.0250
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.