CoChat

Retrospective Analysis of 3-Month Real-World Glucose Data After the MiniMed 670G System Commercial Launch

Stone, Michael P., Agrawal, Pratik, Chen, Xiaoxiao, Liu, Margaret, Shin, John, Cordero, Toni L., Kaufman, Francine R. · 2018 · Diabetes Technology & Therapeutics
Cited by 114

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Real-world data from the first 3141 patients who completed 3 months of SmartGuard™ Auto Mode-enabled MiniMed™ 670G system use during the MiniMed 670G System Commercial Launch are reported. CareLink™ system data uploaded by real-world patients in the Commercial Launch from March 17, 2017 to December 31, 2017 were deidentified and analyzed. Comparisons of overall and night (10:00 PM-07:00 AM) time spent below, within, and above target glucose range (TIR) (70-180 mg/dL) between the baseline Manual Mode and closed-loop Auto Mode periods were made. These were evaluated alongside data from the 124 patients (aged 14-75 years) who completed the 3-month MiniMed 670G system pivotal trial (NCT 2463097), from June 2, 2015 to March 7, 2016. Real-world patients used Auto Mode a median 80.8% of the time (19 h and 24 min of the day). The overall mean of time spent in TIR was 66.0% during baseline Manual Mode versus 73.3% during Auto Mode (P < 0.001); the mean percentage of sensor glucose values <70 mg/dL was 2.7% versus 2.1% (P < 0.001); and that >180 mg/dL was 31.4% versus 24.6% (P < 0.001). The nighttime and early morning (03:00 AM-06:00 AM) TIR during Auto Mode was greater than that during baseline Manual Mode (nighttime: 77.2% vs. 67.4% [P < 0.001], early morning: 70.9% vs. 84.6% [P < 0.001]). Similar differences between Manual Mode and Auto Mode TIR were observed across different age groups. A slight increase in total insulin delivered was also observed. Consistent with improved glycemic control demonstrated in the pivotal trial, analysis of CareLink system data from >3000 real-world patients who completed 3 months of Auto Mode-enabled MiniMed 670G system use demonstrated increased TIR and decreased time below and above TIR compared with baseline. These improved clinical outcomes were observed across a broad age range of patients with type 1 diabetes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2018.0202

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 114

Metadata

Authors
Stone, M. P., Agrawal, P., Chen, X., Liu, M., Shin, J., Cordero, T. L., & Kaufman, F. R.
Venue
Diabetes Technology & Therapeutics
Published
2018-10
Volume
20
Issue
10
Pages
689-692
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2889348059
Cited by
114
References
3
FWCI
10.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.