CoChat

Switching from Suspend-Before-Low Insulin Pump Technology to a Hybrid Closed-Loop System Improves Glucose Control and Reduces Glucose Variability: A Retrospective Observational Case–Control Study

Lepore, Giuseppe, Scaranna, Cristiana, Corsi, Anna, Dodesini, Alessandro Roberto, Trevisan, Roberto · 2020 · Diabetes Technology & Therapeutics
Cited by 24

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

There are no data whether hybrid closed-loop (HCL) systems are superior to sensor-augmented pump (SAP) therapy with predictive low glucose suspend (PLGS) feature in improving glucose control. Aim of our study was to evaluate the effect on metabolic control and glucose variability of the switch from SAP therapy with PLGS to a HCL system in type 1 diabetic individuals. Forty adults with type 1 diabetes, who had been using SAP therapy with PLGS feature (Minimed 640G; Medtronic, Northridge, CA) for at least 12 months were evaluated in a 6-month case–control observational retrospective study. Twenty subjects who consecutively switched from Minimed 640G to a HCL system (Minimed 670G; Medtronic) (670G group) were compared with a control group consisting of 20 subjects who continued with the MiniMed 640G pump (640G group) matched for age, gender, and HbA 1c . At the end of the study there was a significant reduction in average HbA 1c levels (−4.9 ± 6.4 mmol/mol [−0.4% ± 0.6%], P < 0.01), sensor glucose concentrations (−15.4 ± 17.7 mg/dL, P < 0.005), coefficient of variation of sensor glucose concentrations (−3.8% ± 3.6%, P < 0.01), percentage time spent in both hyperglycemic range 181–250 mg/dL (−5.1% ± 4.5%, P < 0.05), and >250 mg/dL (−6.1% ± 6.9%, P < 0.05) in the 670G group, whereas they remained unchanged in the 640G group. Percentage of time spent in euglycemic range significantly increased (11.6% ± 8.3%, P < 0.005) only in the 670G group. There was no change in time spent in hypoglycemic range in both groups. In adults with type 1 diabetes, switching from a 640G to a 670G system significantly improved glucose control and reduced glucose variability, thus reaching in most cases the recommended targets for time spent in euglycemic and hyperglycemic ranges without increasing the risk of hypoglycemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2019.0302

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 24

Metadata

Authors
Lepore, G., Scaranna, C., Corsi, A., Dodesini, A. R., & Trevisan, R.
Venue
Diabetes Technology & Therapeutics
Published
2020-04-01
Volume
22
Issue
4
Pages
321-325
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2980407603
Cited by
24
References
3
FWCI
2.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.