Cited by 2Diabetes Management and ResearchHealth Systems, Economic Evaluations, Quality of LifeDiabetes Management and Education

A Response to: Letter to the Editor with Regard to the Cost-Effectiveness of an Advanced Hybrid Closed-Loop System in People with Type 1 Diabetes: A Health Economic Analysis in Sweden

Open access
Jendle, J., Buompensiere, M. I., Holm, A. L., de Portu, S., Malkin, S. J. P., Cohen, O.·2022·Diabetes Therapy

Abstract

We would like to thank Levrat-Guillen and Ghazi for their interest in our recent analysis relating to the cost-effectiveness of advanced hybrid closed-loop (AHCL) insulin delivery relative to intermittently scanned continuous glucose monitoring (isCGM) in combination with multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII) in people with type 1 diabetes (T1D) [1].Levrat-Guillen and Ghazi have expressed concern over several aspects of the analysis.In an attempt to alleviate these concerns, the issues raised are addressed in a point-by-point fashion below.In the absence of head-to-head comparisons of AHCL versus isCGM, Levrat-Guillen and Ghazi expressed concern over the clinical input data used to inform the analysis.For the isCGM arm, the HbA1c treatment effect was sourced from the real-world FUTURE study published by Charleer et al. [2].Whilst several other potential data sources were available, the FUTURE study was chosen owing to the robust nature and design of the study (e.g., the study was conducted in specialist diabetes centers, with a large number of patients and long duration of follow-up) and a baseline HbA1c value that closely matched the levels observed in the study published by Collyns et al. [3], which was used to inform the AHCL arm.Levrat-Guillen and Ghazi mentioned three sources specifically (Gilbert et al. [4], Evans et al. [5], and Rose et al.[6]) but these studies were not considered for several reasons.The study published by Gilbert et al. [4] was considered inappropriate as the authors assessed the effectiveness of real-time CGM (rtCGM) rather than isCGM; utilization of this study would therefore require the assumption that isCGM and rtCGM are equivalent and evidence from a recent head-to-head study has suggested that this is not the case [7].The metaanalysis by Evans et al. [5] reported a mean HbA1c reduction of 0.56% with isCGM; however, this was based on a large number of studies with baseline HbA1c values ranging from 6.79% to 10.28%.Finally, in the German observational study by Rose et al. [6], patients had a mean

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s13300-022-01252-w

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Multiple analyses have demonstrated the cost-effectiveness of AID, driven by significant reductions in diabetes-related complications.

    “Multiple analyses have demonstrated the cost‐effectiveness of AID, driven by significant reductions in diabetes‐related complications.”

    From Social disadvantage and technology use among adults with type 1 diabetes in Quebec: A cross‐sectional study using data from the Canadian <scp>T1D</scp> ( <scp>BETTER</scp> ) Registry (2025) · cites this paper as [43]

    The response discusses a cost-effectiveness analysis of advanced hybrid closed-loop insulin delivery and reports additional sensitivity analyses (main text and Table 1; page unavailable). It does not establish that multiple independent analyses demonstrated cost-effectiveness driven by significant reductions in diabetes-related complications: the reduction in severe hypoglycemic events was a modeling assumption, while the authors identify reduced fear of hypoglycemia as a key driver. (LLM, conf=0.86)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 9

  1. [1]Levrat-Guillen F, Ghazi T. Cost-effectiveness of intermittently scanned continuous glucose monitoring versus advanced hybrid closed-loop systems in type 1 diabetes: comment on Jendle et al. Diabetes Ther. 10.1007/s13300-022-01251-x. PMC9076758 35403951 · DOI
  2. [4]Gilbert TR Noar A Blalock O Polonsky WH Change in hemoglobin A1c and quality of life with real-time continuous glucose monitoring use by people with insulin-treated diabetes in the landmark study Diabetes Technol Ther 2021 23 S35 S39 10.1089/dia.2020.0666 33470882 PMC7957368 · DOI
  3. [6]Rose L Klausmann G Seibold A Improving HbA1c control in type 1 or type 2 diabetes using flash glucose monitoring: a retrospective observational analysis in two German centres Diabetes Ther 2021 12 363 372 10.1007/s13300-020-00978-9 33314006 PMC7843720 · DOI
  4. [7]Visser MM Charleer S Fieuws S Comparing real-time and intermittently scanned continuous glucose monitoring in adults with type 1 diabetes (ALERTT1): a 6-month, prospective, multicentre, randomised controlled trial Lancet 2021 397 10291 2275 2283 10.1016/S0140-6736(21)00789-3 34089660 · DOI · Paper page
  5. [8]Cordero TL Garg SK Brazg R The effect of prior continuous glucose monitoring use on glycemic outcomes in the pivotal trial of the MiniMed™ 670G hybrid closed-loop system Diabetes Technol Ther 2017 19 749 752 10.1089/dia.2017.0208 29148821 · DOI
  6. [10]Lepore G Scaranna C Corsi A Dodesini AR Trevisan R Switching from suspend-before-low insulin pump technology to a hybrid closed-loop system improves glucose control and reduces glucose variability: a retrospective observational case-control study Diabetes Technol Ther 2020 22 4 321 325 10.1089/dia.2019.0302 31617752 · DOI
  7. [15]Petrovski G Al Khalaf F Campbell J One-year experience of hybrid closed-loop system in children and adolescents with type 1 diabetes previously treated with multiple daily injections: drivers to successful outcomes Acta Diabetol 2021 58 2 207 213 10.1007/s00592-020-01607-4 33044604 PMC7548407 · DOI
  8. [16]Nørgaard K Scaramuzza A Bratina N Routine sensor-augmented pump therapy in type 1 diabetes: the INTERPRET study Diabetes Technol Ther 2013 15 273 280 10.1089/dia.2012.0288 23438304 PMC3696941 · DOI
  9. [17]Al Hayek AA Robert AA Al Dawish MA Evaluation of FreeStyle Libre flash glucose monitoring system on glycemic control, health-related quality of life, and fear of hypoglycemia in patients with type 1 diabetes Clin Med Insights Endocrinol Diabetes 2017 10 10 1179551417746957 29270042 PMC5731614

Cited by

Sorted by citations

Authors
Jendle, J., Buompensiere, M. I., Holm, A. L., de Portu, S., Malkin, S. J. P., & Cohen, O.
Affiliations
  • Örebro University (SE)
  • Medtronic (Switzerland) (CH)
Corresponding author
Jendle, J.
Venue
Diabetes Therapy
Published
2022-04-11
Volume
13
Issue
5
Pages
1125-1129
ISSN
  • 1869-6953 (ISSN-L)
  • 1869-6961
OpenAlex
W4223425727
Cited by
2
References
8
Citations by year
2025: 1 · 2023: 1
Type
journal article
Language
en
Open access
Locations
  • Diabetes Therapy (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Social Sciences › Economics, Econometrics and Finance › Economics and Econometrics › Health Systems, Economic Evaluations, Quality of Life
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
Keywords
advanced hybrid closed-loop system, type 1 diabetes, cost-effectiveness, intermittently scanned continuous glucose monitoring, multiple daily insulin injections, insulin pump therapy, HbA1c reduction, real-world evidence, insulin delivery

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review