Cited by 39Diabetes Management and ResearchHealth Systems, Economic Evaluations, Quality of LifeDiabetes Treatment and Management

Cost-Effectiveness Analysis of a Hybrid Closed-Loop System Versus Multiple Daily Injections and Capillary Glucose Testing for Adults with Type 1 Diabetes

Pease, Anthony, Zomer, Ella, Liew, Danny, Earnest, Arul, Soldatos, Georgia, Ademi, Zanfina, Zoungas, Sophia·2020·Diabetes Technology & Therapeutics

Abstract

Background: Hybrid closed-loop systems may offer improved HbA1c levels, more time-in-range, and less hypoglycemia than alternative treatment strategies. However, it is unclear if glycemic improvements offset this technology's higher acquisition costs. Among adults with type 1 diabetes in Australia, we sought to evaluate the cost-effectiveness of a hybrid closed-loop system in comparison with the current standard of care, comprising insulin injections and capillary glucose testing. Methods: Cost-effectiveness analysis was performed using decision analysis in combination with a Markov model to simulate disease progression in a cohort of adults with type 1 diabetes and compare the downstream health and economic consequences of hybrid closed-loop therapy versus current standard of care. Transition probabilities and utilities were sourced from published studies. Costs were considered from the perspective of the Australian health care system. A lifetime horizon was considered, with annual discount rates of 5% applied to future costs and outcomes. Uncertainty was assessed with probabilistic and deterministic sensitivity analyses. Results: Use of a hybrid closed-loop system resulted in an incremental cost-effectiveness ratio of Australian dollars (AUD) 37,767 per quality-adjusted life year (QALY) gained. This is below the traditionally cited willingness to pay a threshold of $50,000 per QALY gained in the Australian setting. Sensitivity analyses that varied baseline glycemic control,…

Integrity signals

Registry

Crossref · 10.1089/dia.2020.0064

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Pease, A., Zomer, E., Liew, D., Earnest, A., Soldatos, G., Ademi, Z., & Zoungas, S.
Affiliations
  • Monash Health (AU)
  • Monash University (AU)
  • Alfred Health (AU)
Corresponding author
Zoungas, Sophia
Venue
Diabetes Technology & Therapeutics
Published
2020-11
Volume
22
Issue
11
Pages
812-821
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W3019470381
Cited by
39
References
13
Citations by year
2026: 3 · 2025: 7 · 2024: 5 · 2023: 2 · 2022: 11 · 2021: 10 · 2020: 1
FWCI
4.54
Type
journal article
Language
en
Open access
closed
Locations
  • Diabetes Technology & Therapeutics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Social Sciences › Economics, Econometrics and Finance › Economics and Econometrics › Health Systems, Economic Evaluations, Quality of Life
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
type 1 diabetes, hybrid closed-loop system, insulin pump therapy, multiple daily insulin injections, cost-effectiveness, quality-adjusted life years, glycemic control, hypoglycemia, adults
MeSH terms
Adult, Australia, Blood Glucose, Cost-Benefit Analysis, Diabetes Mellitus, Type 1, Humans, Insulin, Insulin Infusion Systems, Quality-Adjusted Life Years

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review