CoChat

Fast-Acting Insulin Aspart Use with the MiniMed TM 670G System

Open access
Hsu, Liana, Buckingham, Bruce, Basina, Marina, Ekhlaspour, Laya, von Eyben, Rie, Wang, Justin, Lal, Rayhan A. · 2021 · Diabetes Technology & Therapeutics
Cited by 57

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Background: This study assessed the efficacy and safety of ultrarapid insulin Fiasp ® in the hybrid closed-loop MiniMed™ 670G system. Methods: This was a pilot randomized double-blinded crossover study among established MiniMed™ 670G users comparing percentage time in range (TIR) and hypoglycemia for Novolog ® and Fiasp. After 2 weeks optimization with their home insulin, participants were randomized to receive Novolog or Fiasp for 2 weeks, followed by the other insulin for the next 2 weeks. Data from the second week of blinded insulin use were analyzed to allow 1 week for 670G adaptation. During the second week, individuals were asked to eat the same breakfast for 3 days to assess differences in meal pharmacodynamics. Results: Nineteen adults were recruited with mean age of 40 ± 18 years, diabetes duration of 27 ± 12 years, and median hemoglobin A1c of 7.1% (6.9, 7.5), using 0.72 (0.4, 1.2) units/(kg·day). For Novolog and Fiasp, respectively, the %TIR (70–180 mg/dL) was 75.3 ± 9.5 and 78.4 ± 9.3; %time <70 mg/dL was 3.1 ± 2.1 and 2.3 ± 2.0; %time >180 mg/dL was 21.6 ± 9.0 and 19.3 ± 8.9; mean glucose was 147 ± 12 and 146 ± 12 mg/dL; coefficient of variation was 28.6% ± 4.5% and 26.8% ± 4.4%; %time in auto mode 86.4 ± 9.2 and 84.4 ± 9.2. All comparisons were nonsignificant for insulin type. Total daily dose (Novolog 48.8 ± 28.4 vs. Fiasp 52.4 ± 31.7 units; P = 0.01) and daily basal (Novolog 17.6 [15.5, 33.8] vs. Fiasp 19.1 [15.3, 38.5] units; P = 0.07) correlated with TIR and %time >180 mg/dL. For insulin delivery in auto mode there was no statistical difference in total daily dose or daily basal between arms. Paired analysis for matched breakfast meals revealed no significant differences in time to maximum glucose, peak glucose, or glucose excursion. Conclusions: In this pilot study, the use of either Novolog or Fiasp in a commercially available MiniMed 670G system operating in auto mode resulted in clinically similar glycemic outcomes, with a slight increase in daily insulin requirements using Fiasp.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2020.0083

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 57

Metadata

Authors
Hsu, L., Buckingham, B., Basina, M., Ekhlaspour, L., von Eyben, R., Wang, J., & Lal, R. A.
Venue
Diabetes Technology & Therapeutics
Published
2021-01-01
Volume
23
Issue
1
Pages
1-7
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W3034091528
Cited by
57
References
8
FWCI
6.69
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.