Effect of Continuous Glucose Monitoring on Glycemic Control in Patients With Type 2 Diabetes Treated With Basal Insulin: A Randomized Clinical Trial
Open accessAbstract
Importance: Continuous glucose monitoring (CGM) has been shown to be beneficial for adults with type 2 diabetes using intensive insulin therapy, but its use in type 2 diabetes treated with basal insulin without prandial insulin has not been well studied. Objective: To determine the effectiveness of CGM in adults with type 2 diabetes treated with basal insulin without prandial insulin in primary care practices. Design, Setting, and Participants: This randomized clinical trial was conducted at 15 centers in the US (enrollment from July 30, 2018, to October 30, 2019; follow-up completed July 7, 2020) and included adults with type 2 diabetes receiving their diabetes care from a primary care clinician and treated with 1 or 2 daily injections of long- or intermediate-acting basal insulin without prandial insulin, with or without noninsulin glucose-lowering medications. Interventions: Random assignment 2:1 to CGM (n = 116) or traditional blood glucose meter (BGM) monitoring (n = 59). Main Outcomes and Measures: The primary outcome was hemoglobin A1c (HbA1c) level at 8 months. Key secondary outcomes were CGM-measured time in target glucose range of 70 to 180 mg/dL, time with glucose level at greater than 250 mg/dL, and mean glucose level at 8 months. Results: Among 175 randomized participants (mean [SD] age, 57 [9] years; 88 women [50%]; 92 racial/ethnic minority individuals [53%]; mean [SD] baseline HbA1c level, 9.1% [0.9%]), 165 (94%) completed the trial. Mean HbA1c level decreased from 9.1% at baseline to 8.0% at 8 months in the CGM group and from 9.0% to 8.4% in the BGM group (adjusted difference, -0.4% [95% CI, -0.8% to -0.1%]; P = .02). In the CGM group, compared with the BGM group, the mean percentage of CGM-measured time in the target glucose range of 70 to 180 mg/dL was 59% vs 43% (adjusted difference, 15% [95% CI, 8% to 23%]; P < .001), the mean percentage of time at greater than 250 mg/dL was 11% vs 27% (adjusted difference, -16% [95% CI, -21% to -11%]; P < .001), and the means of the mean glucose values were 179 mg/dL vs 206 mg/dL (adjusted difference, -26 mg/dL [95% CI, -41 to -12]; P < .001). Severe hypoglycemic events occurred in 1 participant (1%) in the CGM group and in 1 (2%) in the BGM group. Conclusions and Relevance: Among adults with poorly controlled type 2 diabetes treated with basal insulin without prandial insulin, continuous glucose monitoring, as compared with blood glucose meter monitoring, resulted in significantly lower HbA1c levels at 8 months. Trial Registration: ClinicalTrials.gov Identifier: NCT03566693.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Benefits of CGM in T1D include reductions in A1C, fewer severe hypoglycemia events in children and adults, increased time in range, and significant reductions in hospitalizations for severe hypoglycemia and DKA.
“Benefits of CGM in this population include reductions in A1C, fewer severe hypoglycemia events in children and adults, increased TIR, as well as significant reductions in hospitalizations for severe hypoglycemia and DKA.156,162–168”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [167]
The Introduction says prior studies found improved glycemic control with CGM in people with type 1 diabetes. This trial’s reported A1C and time-in-range improvements concern adults with type 2 diabetes, not the claimed type 1 population; its Adverse Events section does not support fewer severe hypoglycemia events or reduced hospitalizations for hypoglycemia or DKA in children or adults with type 1 diabetes. (LLM, conf=0.83)
Experimental — accuracy not yet measuredIn adults with type 2 diabetes (both using and not using insulin), continuous glucose monitoring achieves improved glycated haemoglobin concentrations without impacting the rate of hypoglycaemia.
“Continuous glucose monitoring for adults with type 2 diabetes (both those using and not using insulin)24,25 also achieves improved glycated haemoglobin concentrations without impacting the rate of hypoglycaemia.”
From Blood glucose monitoring devices: current considerations (2023) · cites this paper as [24]
The Abstract reports lower HbA1c with CGM, but this trial enrolled adults using basal insulin, not adults who were not using insulin. Although severe hypoglycemic events occurred in one participant per group, Other Glycemic Outcomes reports a reduction in CGM-measured hypoglycemia, so the broad claim that hypoglycemia rates were unaffected is not supported by this paper. (LLM, conf=0.90)
Experimental — accuracy not yet measuredRandomized controlled trials of the use of rt-CGM, compared with standard blood glucose monitoring, in adults with type 2 diabetes have generally shown reductions in HbA 1c with no significant change in time in hypoglycemia.
“Randomized controlled trials of the use of rt-CGM, compared with standard blood glucose monitoring, in adults with type 2 diabetes have generally shown reductions in HbA 1c with no significant change in time in hypoglycemia (169-172).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [172]
The Primary and Key Secondary Outcomes section reports significantly lower HbA1c with CGM than with blood glucose meter monitoring in adults with type 2 diabetes treated with basal insulin. But the Other Glycemic Outcomes section reports exploratory reductions in time below both 54 mg/dL (P = .001) and 70 mg/dL (P = .02), rather than no significant change in time in hypoglycemia. This trial also cannot establish what trials generally found. (LLM, conf=0.91)
Experimental — accuracy not yet measuredRCT data on rtCGM use in individuals with type 2 diabetes on MDI, mixed therapies, and basal insulin consistently show reductions in A1C and increases in TIR but not a reduction in hypoglycemia rates.
“RCT data on rtCGM use in individuals with type 2 diabetes on MDI (59), mixed therapies (10, 60), and basal insulin (61,62) have consistently shown reductions in A1C levels and increases in TIR (70-180 mg/dL [3.9-10 mmol/L]) but not a reduction in rates of hypoglycemia (63).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [61]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Stratton, I. M. (2000) · BMJ · doi:10.1136/bmj.321.7258.405 · Cited by 9,059 · see citing works
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,032 · see citing works
Self-citationInternational consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069 · see citing works
Self-citationThe Diabetes Control and Complications Trial Research Group (1995) · Diabetes · doi:10.2337/diab.44.8.968 · Cited by 1,301 · see citing works
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185 · see citing works
Self-citationBolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893 · see citing works
Lind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705 · see citing works
Self-citationBeck, R. W., Riddlesworth, T. D., Ruedy, K., Ahmann, A., Haller, S., Kruger, D., McGill, J. B., Polonsky, W., Price, D., Aronoff, S., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2855 · Cited by 635 · see citing works
Self-citationvan Beers, C. A. J., DeVries, J. H., Kleijer, S. J., Smits, M. M., Geelhoed-Duijvestijn, P. H., Kramer, M. H. H., Diamant, M., Snoek, F. J., & Serné, E. H. (2016) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(16)30193-0 · Cited by 386 · see citing works
Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0303 · Cited by 318 · see citing works
Self-citationKleinman, L. C., & Norton, E. C. (2008) · Health Services Research · doi:10.1111/j.1475-6773.2008.00900.x · Cited by 297 · see citing works
Evaluation of the Cascade of Diabetes Care in the United States, 2005-2016
Kazemian, P., Shebl, F. M., McCann, N., Walensky, R. P., & Wexler, D. J. (2019) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2019.2396 · Cited by 252 · see citing works
Murata, G. H., Shah, J. H., Hoffman, R. M., Wendel, C. S., Adam, K. D., Solvas, P. A., Bokhari, S. U., & Duckworth, W. C. (2003) · Diabetes Care · doi:10.2337/diacare.26.6.1759 · Cited by 149 · see citing works
Trends in Insulin Use and Diabetes Control in the U.S.: 1988–1994 and 1999–2012
Selvin, E., Parrinello, C. M., Daya, N. R., & Bergenstal, R. M. (2015) · Diabetes Care · doi:10.2337/dc15-2229 · Cited by 111 · see citing works
Self-citationFast-Acting Insulin Aspart Use with the MiniMed TM 670G System
Hsu, L. J., Buckingham, B. A., Basina, M., Ekhlaspour, L., von Eyben, R., Wang, J. L., & Lal, R. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0083 · Cited by 57 · see citing works
An evaluation of two capillary sample collection kits for laboratory measurement of HbA1c
Beck, R. W., Bocchino, L. E., Lum, J. W., Kollman, C., Barnes-Lomen, V., Sulik, M., Haller, M. J., Bode, B., Cernich, J. T., Killeen, A. A., et al. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0023 · Cited by 42 · see citing works
Self-citationHermanns, N., Schumann, B., Kulzer, B., & Haak, T. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814524105 · Cited by 39 · see citing works
Self-Monitoring of Blood Glucose
Schnell, O., Markolf Hanefeld, E., & Monnier, L. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814528134 · Cited by 30 · see citing works
the AMD Annals-SMBG Study Group, Rossi, M. C., Lucisano, G., Ceriello, A., Mazzucchelli, C., Musacchio, N., Ozzello, A., Nicolucci, A., & Bartolo, P. D. (2018) · Acta Diabetologica · doi:10.1007/s00592-018-1186-z · Cited by 21 · see citing works
Peters, A. L., Cohen, N., Calhoun, P. M., Ruedy, K. J., Beck, R. W., Martens, T. W., Bao, S., Njeru, N. M., Beck, S. E., & Price, D. A. (2020) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14238 · Cited by 10 · see citing works
Self-citationFalk, J., Friesen, K. J., Okunnu, A., & Bugden, S. (2017) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2016.12.007 · Cited by 7 · see citing works
Flagged first, then by citations
2 of the 23 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Davies, M. J., Aroda, V. R., Collins, B. S., Gabbay, R. A., Green, J., Maruthur, N. M., Rosas, S. E., Del Prato, S., Mathieu, C., Mingrone, G., et al. (2022) · Diabetes Care · doi:10.2337/dci22-0034 · Cited by 2,104 · see citing works
“As with other wearables, for example, those collecting steps walked or monitoring dietary intake, medication dose administered, or sleep quality, use of CGM has also been proposed as a motivational tool for those with type 2 diabetes not on insulin therapy, but the evidence on this is modest (337).”
BackgroundMethodSelf-citationDavies, M. J., Aroda, V. R., Collins, B. S., Gabbay, R. A., Green, J., Maruthur, N. M., Rosas, S. E., Del Prato, S., Mathieu, C., Mingrone, G., et al. (2022) · Diabetologia · doi:10.1007/s00125-022-05787-2 · Cited by 1,048 · see citing works
“0 mmol/l [70–180 mg/dl]), fewer hyperglycaemic and hypoglycaemic episodes and improvements in diabetes distress [336, 337].”
Self-citationContinuous glucose monitoring and metrics for clinical trials: an international consensus statement
Battelino, T., Alexander, C. M., Amiel, S. A., Arreaza-Rubin, G., Beck, R. W., Bergenstal, R. M., Buckingham, B. A., Carroll, J., Ceriello, A., Chow, E., et al. (2023) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(22)00319-9 · Cited by 831 · see citing works
Self-citationBlonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507 · see citing works
Self-citationPop‐Busui, R., Januzzi, J. L., Bruemmer, D., Butalia, S., Green, J. B., Horton, W. B., Knight, C. M., Levi, M., Rasouli, N., & Richardson, C. R. (2022) · Diabetes Care · doi:10.2337/dci22-0014 · Cited by 424 · see citing works
“T2D (198)—all of whom are at higher risk”
BackgroundSelf-citationSamson, S. L., Vellanki, P., Blonde, L., Christofides, E. A., Galindo, R. J., Hirsch, I. B., Isaacs, S. D., Izuora, K. E., Low Wang, C. C., Twining, C. L., et al. (2023) · Endocrine Practice · doi:10.1016/j.eprac.2023.02.001 · Cited by 375 · see citing works
Self-citation7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348 · see citing works
Self-citationSacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351 · see citing works
Self-citation7. Diabetes Technology: <i>Standards of Care in Diabetes</i> — <i>2023</i>
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301 · see citing works
Self-citationWearable Devices in Cardiovascular Medicine
Hughes, A. N., Shandhi, M. M. H., Master, H., Dunn, J., & Brittain, E. L. (2023) · Circulation Research · doi:10.1161/circresaha.122.322389 · Cited by 323 · see citing works
7. Diabetes Technology: <i>Standards of Care in Diabetes—2024</i>
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281 · see citing works
Self-citation7. Diabetes Technology: <i>Standards of Medical Care in Diabetes—2022</i>
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358 · see citing works
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Care in Diabetes—2026
Bajaj, M. S., McCoy, R. G., Balapattabi, K., Bannuru, R. R., Bellini, N. J., Bennett, A. K., Beverly, E. A., Early, K. B., ChallaSivaKanaka, S., Echouffo-Tcheugui, J. B., et al. (2025) · Diabetes Care · doi:10.2337/dc26-s009 · Cited by 302 · see citing works
Self-citationContinuous glucose monitoring in adults with type 2 diabetes: a systematic review and meta-analysis
Jancev, M., Vissers, T. A. C. M., Visseren, F. L. J., van Bon, A. C., Serné, E. H., DeVries, J. H., de Valk, H. W., & van Sloten, T. T. (2024) · Diabetologia · doi:10.1007/s00125-024-06107-6 · Cited by 191 · see citing works
Accuracy and Safety of Dexcom G7 Continuous Glucose Monitoring in Adults with Diabetes
Garg, S. K., Kipnes, M., Castorino, K., Bailey, T. S., Akturk, H. K., Welsh, J. B., Christiansen, M. P., Balo, A. K., Brown, S. A., Reid, J. L., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0011 · Cited by 179 · see citing works
Self-citation7. Diabetes Technology: Standards of Care in Diabetes—2026
Bajaj, M. S., McCoy, R. G., Balapattabi, K., Bannuru, R. R., Bellini, N. J., Bennett, A. K., Beverly, E. A., Early, K. B., ChallaSivaKanaka, S., Echouffo-Tcheugui, J. B., et al. (2025) · Diabetes Care · doi:10.2337/dc26-s007 · Cited by 194 · see citing works
Self-citationHypoglycemia in diabetes: An update on pathophysiology, treatment, and prevention
Nakhleh, A., & Shehadeh, N. (2021) · World Journal of Diabetes · doi:10.4239/wjd.v12.i12.2036 · Cited by 170 · see citing works
Sacks, D. B., Arnold, M. A., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad080 · Cited by 157 · see citing works
Self-citationGlycaemic management in diabetes: old and new approaches
Ceriello, A., Prattichizzo, F., Phillip, M., Hirsch, I. B., Mathieu, C., & Battelino, T. (2021) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(21)00245-x · Cited by 146 · see citing works
The relationship between intraocular pressure and glaucoma: An evolving concept
Asrani, S., McGlumphy, E. J., Al‐Aswad, L. A., Chaya, C. J., Lin, S. C., Musch, D. C., Pitha, I., Robin, A. L., Wirostko, B. M., & Johnson, T. V. (2024) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2024.101303 · Cited by 138 · see citing works
Aronson, R., Brown, R. E., Chu, L., Bajaj, H. S., Khandwala, H., Abitbol, A., Malakieh, N., & Goldenberg, R. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.14949 · Cited by 118 · see citing works
“4% (4 mmol/mol) greater lowering of HbA1c and a 15% greater time in target range (TIR) using rtCGM.(4) However, among individuals using only non-insulin therapies for type 2 diabetes, rtCGM use, in periodic exposures, did not show an improvement in HbA1c versus controls.”
Continuous glucose monitoring for the routine care of type 2 diabetes mellitus
Ajjan, R. A., Battelino, T., Cos, X., Del Prato, S., Philips, J.-C., Meyer, L., Seufert, J., & Seidu, S. (2024) · Nature Reviews Endocrinology · doi:10.1038/s41574-024-00973-1 · Cited by 117 · see citing works
“…RCT, which involved 175 individuals with T2DM on basal insulin, showed that CGM can significantly reduce HbA 1c , time in hyperglycaemia (defined as >250 mg/dl (13.9 mmol/l)) and the rate of hypoglycaemia events over an 8-month period, compared with a control group using SMBG testing alone 58 .”
InfluentialJarvis, P. R. E., Cardin, J. L., Nisevich-Bede, P. M., & McCarter, J. P. (2023) · Metabolism · doi:10.1016/j.metabol.2023.155640 · Cited by 86 · see citing works
Yoo, J. H., & Kim, J. H. (2023) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2022.0271 · Cited by 93 · see citing works
A Randomized Trial of Automated Insulin Delivery in Type 2 Diabetes.
Kudva, Y. C., Raghinaru, D., Lum, J. W., Graham, T. E., Liljenquist, D., Spanakis, E. K., Pasquel, F. J., Ahmann, A., Ahn, D. T., Aleppo, G., et al. (2025) · New England Journal of Medicine · doi:10.1056/nejmoa2415948 · Cited by 83 · see citing works
Self-citationAleppo, G., Beck, R. W., Bailey, R., Ruedy, K. J., Calhoun, P., Peters, A. L., Pop-Busui, R., Philis-Tsimikas, A., Bao, S., Umpierrez, G., et al. (2021) · Diabetes Care · doi:10.2337/dc21-1304 · Cited by 82 · see citing works
“Methods for the initial 8-month randomized trial have been reported (6,7).”
BackgroundSelf-citationCommercial and Scientific Solutions for Blood Glucose Monitoring—A Review
Xue, Y., Thalmayer, A. S., Zeising, S., Fischer, G., & Lübke, M. (2022) · Sensors · doi:10.3390/s22020425 · Cited by 85 · see citing works
Bao, S., Bailey, R., Calhoun, P., & Beck, R. W. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0494 · Cited by 81 · see citing works
“Details of the protocol and methods have been previously published 7,8 ; relevant aspects of the protocol are summarized hereunder.”
Self-citationMayberry, L. S., Guy, C., Hendrickson, C. D., McCoy, A. B., & Elasy, T. A. (2023) · Journal of General Internal Medicine · doi:10.1007/s11606-023-08222-3 · Cited by 79 · see citing works
Lin, J. B., Narayanan, R., Philippakis, E., Yonekawa, Y., & Apte, R. S. (2024) · Nature Reviews Disease Primers · doi:10.1038/s41572-024-00501-5 · Cited by 75 · see citing works
“In addition, in patients requiring insulin, approaches for continuous glucose monitoring have been shown to improve glycaemic control as evidenced by significantly lower HbA1c levels 125 .”
Uhl, S., Choure, A., Rouse, B., Loblack, A., & Reaven, P. (2024) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgad652 · Cited by 76 · see citing works
Moon, J. S., Kang, S., Choi, J. H., Lee, K. A., Moon, J. H., Chon, S., Kim, D. J., Kim, H. J., Seo, J. A., Kim, M. K., et al. (2024) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2024.0249 · Cited by 76 · see citing works
Oser, T. K., Hall, T. L., Dickinson, L. M., Callen, E. F., Carroll, J. K., Nease, D. E., Michaels, L. C., & Oser, S. M. (2022) · The Annals of Family Medicine · doi:10.1370/afm.2876 · Cited by 79 · see citing works
Lind, N., Christensen, M. B., Hansen, D. L., & Nørgaard, K. (2024) · Diabetes Care · doi:10.2337/dc23-2194 · Cited by 73 · see citing works
Carlson, A. L., Daniel, T. D., DeSantis, A., Jabbour, S. A., French, E. K., Kruger, D. F., Miller, E. M., Özer, K., & Elliott, T. (2022) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2021-002590 · Cited by 73 · see citing works
Self-citationReaven, P. D., Newell, M., Rivas, S., Zhou, X., Norman, G. J., & Zhou, J. (2023) · Diabetes Care · doi:10.2337/dc22-2189 · Cited by 73 · see citing works
Moon, S. J., Kim, K., Lee, W. J., Lee, M. Y., Vigersky, R., & Park, C. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.14852 · Cited by 69 · see citing works
“The use of RT-CGM in people with T2D has not been as well-documented, and most of those studies reporting its use in that population have included subjects on insulin.(12,13) Some continuous glucose monitoring (CGM) studies conducted in patients with T2D included participants using only OADs, but these studies also in…”
Expanding the Role of Continuous Glucose Monitoring in Modern Diabetes Care Beyond Type 1 Disease
Klupa, T., Czupryniak, L., Dzida, G. J., Fichna, P., Jarosz-Chobot, P. A., Gumprecht, J., Myśliwiec, M., Szadkowska, A., Bomba-Opon, D. A., Czajkowski, K., et al. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01431-3 · Cited by 85 · see citing works
“Use of CGM in people with T2DM on basal-only insulin is associated with improvements in HbA1c while reducing hypoglycemia [19].”
MethodNdumele, C. E., Rodríguez, F., Dixon, D. L., Khan, S. S., Mukherjee, D., Bajaj, M. S., Bangalore, S., Bozkurt, B., Breathett, K. K., Clarke, S. L., et al. (2026) · Circulation · doi:10.1161/cir.0000000000001453 · Cited by 87 · see citing works
Riveline, J.-P., Roussel, R., Vicaut, E., de Pouvourville, G., Detournay, B., Emery, C., Levrat-Guillen, F., & Guerci, B. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0085 · Cited by 64 · see citing works
Health Care Disparities in Use of Continuous Glucose Monitoring
Isaacs, D. M., Bellini, N. J., Biba, U., Cai, A., & Close, K. L. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0268 · Cited by 61 · see citing works
Shaw, J. L. V., Bannuru, R. R., Beach, L. A., ElSayed, N. A., Freckmann, G., Füzéry, A. K., Fung, A. W. S., Gilbert, J. D., Yun, H., Korpi-Steiner, N. L., et al. (2024) · Diabetes Care · doi:10.2337/dci24-0073 · Cited by 65 · see citing works
Self-citationNatale, P., Chen, S., Chow, C. K., Cheung, N. W., Martinez‐Martin, D., Caillaud, C., Scholes‐Robertson, N., Kelly, A., Craig, J. C., Strippoli, G., et al. (2023) · Journal of Diabetes · doi:10.1111/1753-0407.13454 · Cited by 63 · see citing works
The Glucose Management Indicator: Time to Change Course?
Selvin, E. (2024) · Diabetes Care · doi:10.2337/dci23-0086 · Cited by 64 · see citing works
Choe, H. J., Rhee, E.-J., Won, J. C., Park, K. S., Lee, W.-Y., & Cho, Y. M. (2022) · Diabetes Care · doi:10.2337/dc22-0764 · Cited by 59 · see citing works
“basal insulin in patients with T2D (11,12).”
Digital Technology for Diabetes
Hughes, M. S., Addala, A., & Buckingham, B. (2023) · New England Journal of Medicine · doi:10.1056/nejmra2215899 · Cited by 59 · see citing works
Ndumele, C. E., Rodriguez, F., Dixon, D. L., Khan, S. S., Mukherjee, D., Bajaj, M., Bangalore, S., Bozkurt, B., Breathett, K., Clarke, S. L., et al. (2026) · JACC · doi:10.1016/j.jacc.2026.03.056 · Cited by 90 · see citing works
Galindo, R. J., Ali, M. K., Funni, S. A., Dodge, A. B., Kurani, S. S., Shah, N. D., Umpierrez, G. E., & McCoy, R. G. (2022) · Diabetes Care · doi:10.2337/dc21-1579 · Cited by 53 · see citing works
Self-citationContinuous Glucose Monitoring Use in Older Adults for Optimal Diabetes Management
Munshi, M. N. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0111 · Cited by 53 · see citing works
“In a subanalysis of the randomized MOBILE study, 28 Bao et al. evaluated the effectiveness and safety in 42 T2D adults, age ‡ 65 years (range 56–79 years), treated with basal insulin.”
Chun, K., Oh, J., Lee, C. J., Park, J. J., Lee, S. E., Kim, M., Cho, H., Choi, J., Lee, H., Hwang, K., et al. (2022) · Cardiovascular Diabetology · doi:10.1186/s12933-022-01720-4 · Cited by 50 · see citing works
Chen, E., Prakash, S., Reddi, V. J., Kim, D. A., & Rajpurkar, P. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01115-0 · Cited by 51 · see citing works
How Continuous Glucose Monitoring Can Motivate Self-management: Can Motivation Follow Behaviour?
Vallis, M., Ryan, H., Berard, L., Cosson, E., Kristensen, F. B., Levrat‐Guillen, F., Naïditch, N., RABASA-LHORET, R. P. R., & Polonsky, W. H. (2023) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2023.04.001 · Cited by 48 · see citing works
Self-citationThe History, Evolution and Future of Continuous Glucose Monitoring (CGM)
Bender, C., Vestergaard, P., & Cichosz, S. L. (2025) · Diabetology · doi:10.3390/diabetology6030017 · Cited by 43 · see citing works
Aggarwal, A., Pathak, S., & Goyal, R. (2022) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2022.109825 · Cited by 47 · see citing works
Crawford, A. L., & Laiteerapong, N. (2024) · Annals of Internal Medicine · doi:10.7326/aitc202406180 · Cited by 47 · see citing works
Kong, A. P. S., Lim, S. K., Yoo, S.-H., Ji, L., Chen, L., Bao, Y., Yeoh, E. C. K., Chan, S.-P., Wang, C., Mohan, V., et al. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.110718 · Cited by 48 · see citing works
Self-citationOser, T. K., Litchman, M. L., Allen, N. A., Kwan, B. M., Fisher, L., Jortberg, B. T., Polonsky, W. H., & Oser, S. M. (2021) · Current Diabetes Reports · doi:10.1007/s11892-021-01408-1 · Cited by 43 · see citing works
Self-citationComprehensive Telehealth Model to Support Diabetes Self-Management
Aleppo, G., Gal, R. L., Raghinaru, D., Kruger, D., Beck, R. W., Bergenstal, R. M., Cushman, T., Hood, K. K., Johnson, M. L., McArthur, T., et al. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.36876 · Cited by 42 · see citing works
“The median (IQR) number of additional follow-up contacts per participant was 8 (6-10).”
BackgroundSelf-citationComparisons of Fifth-, Sixth-, and Seventh-Generation Continuous Glucose Monitoring Systems
Welsh, J. B., Psavko, S., Zhang, X., Gao, P., & Balo, A. K. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221099879 · Cited by 43 · see citing works
Self-citationEmerging Diabetes Technologies: Continuous Glucose Monitors/Artificial Pancreases
ALMURASHI, A. M., Rodriguez, E., & Garg, S. K. (2023) · Journal of the Indian Institute of Science · doi:10.1007/s41745-022-00348-3 · Cited by 48 · see citing works
Clark, T. L., Polonsky, W. H., & Soriano, E. C. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0612 · Cited by 41 · see citing works
Self-citationIdentifying the deficiencies of currently available <scp>CGM</scp> to improve uptake and benefit
Barnard‐Kelly, K. D., Martínez‐Brocca, M. A., Glatzer, T., & Oliver, N. (2024) · Diabetic Medicine · doi:10.1111/dme.15338 · Cited by 37 · see citing works
Reddy, M., & Oliver, N. S. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15504 · Cited by 40 · see citing works
Isitt, J. J., Roze, S., Sharland, H., Cogswell, G., Alshannaq, H. A., Norman, G. J., & Lynch, P. M. (2022) · Diabetes Therapy · doi:10.1007/s13300-022-01324-x · Cited by 37 · see citing works
Kim, J. Y., Jin, S.-M., Sim, K. H., Kim, B.-Y., Cho, J. H., Moon, J. S., Lim, S., Kang, E. S., Park, C.-Y., Kim, S. G., et al. (2024) · Diabetologia · doi:10.1007/s00125-024-06152-1 · Cited by 36 · see citing works
Zhang, Z., Wang, Y., Lu, J., & Zhou, J. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.16033 · Cited by 36 · see citing works
“6 As CGM has gained progressively wider clinical application, new metrics derived from this technology have emerged, including time in range (TIR 3.9 – 10.0 13 Hence, TIR has been consistently recommended by international consensus statements and guidelines as a valid measure of glycemic control.”
InfluentialLu, J., Ying, Z., Wang, P., Fu, M., Han, C., & Zhang, M. (2024) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.15328 · Cited by 39 · see citing works
Czupryniak, L., Dzida, G. J., Fichna, P., Jarosz-Chobot, P. A., Gumprecht, J., Klupa, T., Myśliwiec, M., Szadkowska, A., Bomba-Opon, D. A., Czajkowski, K., et al. (2022) · Diabetes Therapy · doi:10.1007/s13300-022-01229-9 · Cited by 35 · see citing works
“Importantly, the use of CGM systems is proven to reduce HbA1c in people with type 1 diabetes or type 2 diabetes [3] on intensive insulin therapy, but they are equally effective for people with type 2 diabetes on basal insulin therapy only [4, 5] or those on non-insulin therapy [4].”
BackgroundKong, S.-Y., & Cho, M.-K. (2024) · Healthcare · doi:10.3390/healthcare12050571 · Cited by 36 · see citing works
Zelada, H., Perez‐Guzman, M. C., Cherñavvsky, D. R., & Galindo, R. J. (2023) · Endocrine Connections · doi:10.1530/ec-23-0180 · Cited by 34 · see citing works
“Interestingly, there is also evidence of its benefits in reducing HbA1C in people with T2D on long-acting basal insulin (23).”
BackgroundNathanson, D., Eeg‐Olofsson, K., Spelman, T. D., Bülow, E., Kyhlstedt, M., Levrat‐Guillen, F., & Bolinder, J. (2024) · Diabetologia · doi:10.1007/s00125-024-06289-z · Cited by 34 · see citing works
Aleppo, G., Hirsch, I. B., Parkin, C. G., McGill, J., Galindo, R., Kruger, D. F., Levy, C. J., Forlenza, G. P., Umpierrez, G. E., Grunberger, G., et al. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0268 · Cited by 34 · see citing works
Self-citationJohnston, A. R., Poll, J. B., Hays, E., & Jones, C. W. (2022) · Diabetes Epidemiology and Management · doi:10.1016/j.deman.2022.100068 · Cited by 33 · see citing works
Continuous Glucose Monitoring to Optimize Management of Diabetes in Patients with Advanced CKD
Galindo, R. J., de Boer, I. H., Neumiller, J. J., & Tuttle, K. R. (2022) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.04510422 · Cited by 35 · see citing works
Prasad‐Reddy, L., Godina, A., Chetty, A. K., Close Concerns, S. F., & Isaacs, D. (2022) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2022.18.2.116 · Cited by 33 · see citing works
Accuracy of continuous glucose monitoring in the hospital setting: an observational study
O’Connor, M. Y., Flint, K. L., Sabean, A., Ashley, A. L., Zheng, H., Yan, J., Steiner, B. A., Anandakugan, N., CALVERLEY, M. M., Bartholomew, R. A., et al. (2024) · Diabetologia · doi:10.1007/s00125-024-06250-0 · Cited by 35 · see citing works
“In the outpatient setting, continuous glucose monitoring (CGM) has been shown to improve glycaemic control in people with diabetes [10–13], and has been approved by regulatory agencies for use in determination of appropriate insulin dosing without the need for fingerstick glucose confirmation.”
Accuracy of Continuous Glucose Monitoring in Hemodialysis Patients With Diabetes
Narasaki, Y., Kalantar‐Zadeh, K., Daza, A. C., You, A. S., Novoa, A., Peralta, R. A., Siu, M. K. M., Nguyen, D. V., & Rhee, C. M. (2024) · Diabetes Care · doi:10.2337/dc24-0635 · Cited by 34 · see citing works
Consensus Report on the Use of Continuous Glucose Monitoring in Chronic Kidney Disease and Diabetes
Rhee, C. M., Gianchandani, R. Y., Kerr, D. E., Philis‐Tsimikas, A., Kovesdy, C. P., Stanton, R. C., Drincic, A., Galindo, R. J., Kalantar‐Zadeh, K., Neumiller, J. J., et al. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241292041 · Cited by 34 · see citing works
“109,164,165 Motivated by these observations, DTS convened a panel of experts in nephrology and diabetes to review and discuss the current state of evidence, challenges, and future research directions centered on the use of CGM technology in patients with diabetes and CKD. Conclusions were based on…”
Self-citationBattelino, T., Lalic, N. M., Hussain, S., Ceriello, A., Majanović, S. K., Davies, S., Topsever, P., Heverly, J., Ulivi, F., Brady, K., et al. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2025.112111 · Cited by 34 · see citing works
Davis, G. M., Bailey, R. J., Calhoun, P. M., Price, D. A., & Beck, R. W. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0489 · Cited by 33 · see citing works
“9% and mean (–SD) baseline TIR 70–180 mg/dL was 40% – 25%.(21,22) Potential participants were recruited from primary care practices and were not under the care of an endocrinologist to manage their diabetes.”
BackgroundMethodInfluentialSelf-citationNorman, G. J., Paudel, M. L., Parkin, C. G., Bancroft, T., & Lynch, P. M. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0525 · Cited by 32 · see citing works
“…and real-world retrospective and prospective observational studies, use of rtCGM facilitates reductions in glycated hemoglobin (HbA1c), 11–17 increased time in target glucose range 11–17 and reductions in hypoglycemia risk, 18 with corresponding reductions in diabetes-related hospitalizations.”
Blood Glucose Level Time Series Forecasting: Nested Deep Ensemble Learning Lag Fusion
Khadem, H., Nemat, H., Elliott, D., & Benaissa, M. (2023) · Bioengineering · doi:10.3390/bioengineering10040487 · Cited by 34 · see citing works
“For example, technological breakthroughs, such as continuous glucose monitoring biosensors [17,18] and insulin pumps [19,20], nowadays, serve myriads of type 1 diabetes patients.”
BackgroundAlkabbani, W., CROMER, S. J., Kim, D. H., Paik, J. M., Bykov, K., Munshi, M. N., Wexler, D. J., & Patorno, E. (2025) · Diabetes Care · doi:10.2337/dca25-0006 · Cited by 28 · see citing works
Porter, M., Fonda, S. J., Swigert, T. J., & Ehrhardt, N. M. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211053886 · Cited by 28 · see citing works
Wearable Microfluidics for Continuous Assay
Lin, P.-H., Nien, H.-H., & Li, B.-R. (2023) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-091322-082930 · Cited by 28 · see citing works
Szmuilowicz, E. D., & Aleppo, G. (2022) · Postgraduate Medicine · doi:10.1080/00325481.2022.2110507 · Cited by 27 · see citing works
Diabetes: the role of continuous glucose monitoring
Kluemper, J. R., Smith, A. C., & Wobeter, B. R. (2022) · Drugs in Context · doi:10.7573/dic.2021-9-13 · Cited by 29 · see citing works
Shields, S., Thomas, R., Durham, J., Moran, J., Clary, J., & Ciemins, E. L. (2024) · Scientific Reports · doi:10.1038/s41598-024-83548-4 · Cited by 28 · see citing works
Omotosho, I. A., Shamsuddin, N., Huri, H. Z., Chong, W. L., & Rehman, I. U. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26146909 · Cited by 29 · see citing works
“%) in insulin-treated patients, surpassing traditional blood glucose meters (BGM) [39].”
NiNP/Cu-MOF-C/GCE for the the noninvasive detection of glucose in natural saliva samples
Feng, L., Lin, X., Feng, J., Min, X., & Ni, Y. (2023) · Microchemical Journal · doi:10.1016/j.microc.2023.108657 · Cited by 26 · see citing works
Short-term use of CGM in youth onset type 2 diabetes is associated with behavioral modifications
Manfredo, J., Lin, T., Gupta, R., Abiola, K., West, M., Busin, K., Tracey, J., Brown, E. A., Magge, S. N., & Wolf, R. M. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1182260 · Cited by 25 · see citing works
Estimating Glycemia From HbA1c and CGM: Analysis of Accuracy and Sources of Discrepancy
Tozzo, V., Genco, M. T., Omololu, S. O., Mow, C., Patel, H. R., Patel, C. H., Ho, S. N., Lam, E., Abdulsater, B., Patel, N., et al. (2024) · Diabetes Care · doi:10.2337/dc23-1177 · Cited by 27 · see citing works
Lu, Y., Liu, D., Liang, Z., Liu, R., Chen, P., Liu, Y., Li, J., Feng, Z., Li, L. M., Sheng, B., et al. (2025) · National Science Review · doi:10.1093/nsr/nwaf039 · Cited by 31 · see citing works
“Evidence from clinical research has demonstrated that CGM devices can improve glycemic con-trol for people with T2DM, as well as more-timely treatment intensification, lower risk of diabetes complications and hospital admissions [86 –88 ].”
Wafa, I. A., Pratama, N. R., Sofia, N. F., Anastasia, E. S., Konstantin, T., Wijaya, M. A., Wiyono, M. R., Djuari, L., & Novida, H. (2022) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2021.0125 · Cited by 24 · see citing works
Kalyani, R. R., Allende-Vigo, M. Z., Antinori-Lent, K. J., Close, K. L., Das, S. R., Deroze, P., Edelman, S. V., El Sayed, N. A., Kerr, D., Neumiller, J. J., et al. (2024) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgad745 · Cited by 25 · see citing works
From reactive to proactive: Continuous protein monitoring for preventive health care
Donnelly, J. M., Neff, R. A., Sedlack, A. J. H., Juska, V. B., Ayala‐Cardona, L. F., Bass, J. T., McNally, E. M., Shah, S. J., Alshurafa, N. I., Kimchi, E. Y., et al. (2025) · Science · doi:10.1126/science.ady6497 · Cited by 25 · see citing works
Glycaemic control in people with diabetes following acute myocardial infarction
Esdaile, H., Hill, N. E., Mayet, J., & Oliver, N. S. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.110644 · Cited by 27 · see citing works
Interruption of Continuous Glucose Monitoring: Frequency and Adverse Consequences
Markov, A. M., Krutilova, P., Cedeno, A., McGill, J. B., & McKee, A. M. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231156572 · Cited by 22 · see citing works
Self-citationSamson, S. L., Vellanki, P., Blonde, L., Hirsch, I. B., Hoang, T. D., Isaacs, S. D., Izuora, K. E., Wang, C. C. L., Ooi, C. P., Padilla, B. I., et al. (2026) · Endocrine Practice · doi:10.1016/j.eprac.2026.01.006 · Cited by 27 · see citing works
Self-citationContinuous Glucose Monitoring in Older Adults: What We Know and What We Have Yet to Learn
Price, C. E., Callahan, K. E., Aloi, J., & Usoh, C. O. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241234651 · Cited by 23 · see citing works
“16 Similar HbA1c lowering was noted in the RCT by Martens et al 17 who evaluated adults with T2DM managed with MDI or noninsulin glycemic medications, noting a reduction by −1.1% in the CGM arm versus −0.6% Hb A1c reduction in the FSBG arm.”
BackgroundInfluential
- Authors
- Martens, T., Beck, R. W., Bailey, R., Ruedy, K. J., Calhoun, P., Peters, A. L., Pop-Busui, R., Philis-Tsimikas, A., Bao, S., Umpierrez, G., Davis, G., Kruger, D., Bhargava, A., Young, L., McGill, J. B., Aleppo, G., Nguyen, Q. T., Orozco, I., Biggs, W., Lucas, K. J., Polonsky, W. H., Buse, J. B., Price, D., Bergenstal, R. M., MOBILE Study Group, Carlson, A., Chambers, S., Yang, S., Kirkman, M. S., Kass, A., Fraser, R., Cushman, T., Ramos, C., Magar, M., Walker, M., Serafin-Dokhan, S., Salam, M., Hurst, S., Clifton, M. J., Kravarusic, J., Bansal, A., Fulkerson, C., Ang, L., Richardson, C., Mizokami-Stout, K., Reiss, J., Leone, V., Stifel, K., Dailey, G., Change, A., McCallum, J., Garcia, M. I., Davis, D., Lovell, C., Root, C., Toler, F., Wilhelm, L., Eifert, R., Murguia, L., Cota, B., Nguyen, L., Lipski, R., Lawrence, M. K., Fournier, A., Carter, M., Hoover, S., Cohen, N., Mouse, T., Rusnak, J., Campos, T., Njeru, N., Arant, T., Beck, S. E., & Balo, A.
- Affiliations
- Park Nicollet Health Services (US)
- Jaeb Center for Health Research (US)
- University of Southern California (US)
- University of Michigan, Ann Arbor
- Scripps Whittier Diabetes Institute, San Diego, California
- Vanderbilt University Medical Center (US)
- Emory University (US)
- Henry Ford Health (US)
- Iowa Diabetes Research, West Des Moines
- University of North Carolina at Chapel Hill (US)
- Washington University in St. Louis (US)
- Northwestern University (US)
- Las Vegas Endocrinology, Henderson, Nevada
- Carteret General Hospital (US)
- Amarillo Medical Specialists, Amarillo, Texas
- Diabetes & Endocrinology Consultants PC, Morehead City, North Carolina
- Behavioral Diabetes Institute, San Diego, California
- Dexcom (United States) (US)
- HealthPartners (US)
- for the MOBILE Study Group
- Corresponding author
- Beck, Roy W.
- ORCID
- Martens, Thomas
- Beck, Roy W.
- Bailey, Ryan
- Calhoun, Peter
- Peters, Anne L.
- Bao, Shichun
- Umpierrez, Guillermo
- Davis, Georgia
- Kruger, Davida
- Bhargava, Anuj
- Young, Laura
- McGill, Janet B.
- Aleppo, Grazia
- Polonsky, William H.
- Buse, John B.
- Price, David
- Bergenstal, Richard M.
- Carlson, Anders
- Yang, Shoua
- Kirkman, Marian Sue
- Serafin-Dokhan, Sara
- Salam, Maamoun
- Ang, Lynn
- Richardson, Caroline
- Leone, Virginia
- Dailey, George
- Hoover, Stephanie
- Cohen, Nathan
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2021-06-08
- Volume
- 325
- Issue
- 22
- Pages
- 2262
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- PMC
- PMC8173473
- OpenAlex
- W3164064295
- Cited by
- 543
- References
- 23
- Citations by year
- 2026: 116 · 2025: 132 · 2024: 107 · 2023: 98 · 2022: 65 · 2021: 24
- FWCI
- 54.81
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- JAMA (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (UL1TR001422)
- National Institute of Diabetes and Digestive and Kidney Diseases (P30DK092926, P30DK020572, P30DK124723, P30DK111022)
- National Center for Advancing Translational Sciences
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- continuous glucose monitoring, type 2 diabetes, basal insulin, glycemic control, HbA1c, blood glucose meters, time in target glucose range, primary care, intensive insulin therapy, glycemic variability, hypoglycemia, hyperglycemia, HbA1c reduction, HbA1c variability
- MeSH terms
- Glycemic Control, Aged, Blood Glucose, Diabetes Mellitus, Type 2, Female, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Insulin, Male, Middle Aged, Time Factors, Confidence Intervals, Treatment Outcome, Patient Satisfaction, Sample Size, Postprandial Period
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review