CoChat

Essential Continuous Glucose Monitoring Metrics: The Principal Dimensions of Glycemic Control in Diabetes

Montaser, Eslam, Fabris, Chiara, Kovatchev, Boris · 2022 · Diabetes Technology & Therapeutics
Cited by 41

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

Background: With the proliferation of continuous glucose monitoring (CGM), a number of metrics were developed to assess quality of glycemic control. Many of them are highly correlated. Thus, we aim to identify the principal dimensions of glycemic control—a minimal set of metrics, necessary and sufficient for comprehensive assessment of diabetes management. Methods: Seventy-five thousand five hundred sixty-three 2-week CGM profiles recorded in six studies by 790 individuals with type 1 or type 2 diabetes were used to compute mean glucose (MG), percentage time >180 mg/dL (TAR), >250 mg/dL (TAR2), <70 mg/dL (TBR), <54 mg/dL (TBR2), and coefficient of variation (CV). The true dimensionality of the glycemic-metric space was identified in a training set (53,380 profiles) and validated in an independent test set (22,183 profiles). Results: Correlation analysis identified two blocks of metrics—(MG, TAR, TAR2) and (TBR, TBR2, CV)—each with high internal correlation, but insignificant between-block correlation, suggesting that the true dimensionality of the glycemic-metric space is 2. Principal component analysis confirmed two essential metrics quantifying exposure to hyperglycemia (i.e., treatment efficacy) and risk for hypoglycemia (i.e., treatment safety), and explaining ∼90% of the variance in the training and test data. Conclusion: Two essential metrics, treatment efficacy and treatment safety, are necessary and sufficient to characterize glycemic control in diabetes. Thus, quantitatively, diabetes treatment optimization is reduced to a two-dimensional problem, meaning that minimizing both exposure to hyperglycemia and risk for hypoglycemia will lead to improvement in any other metric of glycemic control.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2022.0104

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 41

Metadata

Authors
Montaser, E., Fabris, C., & Kovatchev, B.
Venue
Diabetes Technology & Therapeutics
Published
2022-11-01
Volume
24
Issue
11
Pages
797-804
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W4283077142
Cited by
41
References
19
FWCI
4.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Essential Continuous Glucose Monitoring Metrics: The Principal Dimensions of Glycemic Control in Diabetes. https://app.cochat.ai/papers/10.1089/dia.2022.0104
The paper
Montaser, E., Fabris, C., & Kovatchev, B. (2022). Essential Continuous Glucose Monitoring Metrics: The Principal Dimensions of Glycemic Control in Diabetes. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2022.0104

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.