The DOI matches its Crossref record.
Does Training on a Virtual Reality Robotic Simulator Improve Performance on the da Vinci ® Surgical System?
Abstract
PURPOSE: The primary objective of this study is to determine if training on the Mimic dV-Trainer (MdVT) simulator results in improved ability on the da Vinci surgical system (dVSS) using exercises with inanimate objects. MATERIALS AND METHODS: Twelve trainees (MdVT group) and 10 residents and one fellow (dVSS group) were recruited for the study. Each participant in the MdVT group completed one session of five exercises on the dVSS that were scored for timing and accuracy, followed by four training sessions on the MdVT, and concluded with a final session on the dVSS in which the initial exercises were repeated. Improvement on the dVSS exercises was compared with dVSS group who completed four to six training sessions using the same exercises on the dVSS without any simulator training. RESULTS: Both groups had similar significant improvements in the Letter Board and String Running exercises for both timing and accuracy. The MdVT group demonstrated significant improvement in the Pattern Cutting and Peg Board times. Only the dVSS group significantly improved in the Knot Tying time and the Peg Board accuracy. CONCLUSION: Training with the MdVT provided similar improvement on five exercises performed on the dVSS when compared with training on the dVSS alone. The use of this simulator in resident and student training may help bridge the gap between the safe acquisition of surgical skills and effective performance during live robot-assisted surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cook, D. A., Hamstra, S. J., Brydges, R., Zendejas, B., Szostek, J. H., Wang, A. T., Erwin, P. J., & Hatala, R. (2013) · Medical Teacher · doi:10.3109/0142159x.2012.714886 · Cited by 709
Goh, A. C., Goldfarb, D. W., Sander, J. C., Miles, B. J., & Dunkin, B. J. (2012) · Journal of Urology · doi:10.1016/j.juro.2011.09.032 · Cited by 480
Medical Robots: Current Systems and Research Directions
Beasley, R. A. (2012) · Journal of Robotics · doi:10.1155/2012/401613 · Cited by 312
A Systematic Review of Virtual Reality Simulators for Robot-assisted Surgery
Moglia, A., Ferrari, V., Morelli, L., Ferrari, M., Mosca, F., & Cuschieri, A. (2016) · European Urology · doi:10.1016/j.eururo.2015.09.021 · Cited by 300
Visuo-tactile integration and body ownership during self-generated action
Rognini, G., Sengül, A., Aspell, J. E., Salomon, R., Bleuler, H., & Blanke, O. (2013) · European Journal of Neuroscience · doi:10.1111/ejn.12128 · Cited by 46
Metadata
- Authors
- Lerner, M. A., Ayalew, M., Peine, W. J., & Sundaram, C. P.
- Venue
- Journal of Endourology
- Publisher
- SAGE Publications
- Published
- 2010-03
- Volume
- 24
- Issue
- 3
- Pages
- 467-472
- ISSN
- 0892-7790 (ISSN-L)
- 1557-900X
- OpenAlex
- W2038965490
- Cited by
- 165
- References
- 0
- FWCI
- 19.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Does Training on a Virtual Reality Robotic Simulator Improve Performance on the da Vinci ® Surgical System? https://app.cochat.ai/papers/10.1089/end.2009.0190
- The paper
- Lerner, M. A., Ayalew, M., Peine, W. J., & Sundaram, C. P. (2010). Does Training on a Virtual Reality Robotic Simulator Improve Performance on the da Vinci ® Surgical System? Journal of Endourology. https://doi.org/10.1089/end.2009.0190
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.