The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Origin of Exhaled Breath Particles from Healthy and Human Rhinovirus-Infected Subjects
Open accessAbstract
Background: Exhaled breath studies suggest that humans exhale fine particles during tidal breathing, but little is known of their physical origin in the respiratory system during health or disease. Methods: Particles generated by 3 healthy and 16 human rhinovirus (HRV)-infected subjects were counted using an optical particle counter with nominal diameter-size bins ranging between 0.3 and 10 μm. Data were collected from HRV-infected subjects during tidal breathing. In addition, data from healthy subjects were collected during coughs, swallows, tidal breathing, and breathing to total lung capacity (TLC) and residual volume (RV). Using general additive models, we graphed exhaled particle concentration versus airflow during exhalation. Exhaled particles were collected from expired air on gelatin filters and analyzed for HRV via quantitative PCR. Results: HRV-infected subjects exhaled from 0.1 to 7200 particles per liter of exhaled air during tidal breathing (geometric mean = 32 part/L). A small fraction (24%) of subjects exhaled most (81%) of the particles measured and 82% of particles detected were 0.300–0.499 μm. Minute ventilation, maximum airflow during exhalation, and forced expiratory volume 1 second (FEV 1 % predicted) were positively correlated with particle production. No human rhinovirus was detected in exhaled breath samples. Three healthy subjects exhaled less than 100 particles per liter of exhaled air during tidal breathing and increased particle concentrations more with exhalation to RV than with coughing, swallowing, or rapid exhalation. Conclusions: Submicron particles were detected in the exhaled breath of healthy and HRV-infected subjects. Particle concentrations were correlated with airflow during the first half of exhalation, and peaked at the end of exhalation, indicating both lower and upper airways as particle sources. The effect of breathing maneuver suggested a major contribution from lower airways, probably the result of opening collapsed small airways and alveoli.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690
Influenza Virus in Human Exhaled Breath: An Observational Study
Fabian, P., McDevitt, J. J., DeHaan, W. H., Fung, R. O. P., Cowling, B. J., Chan, K. H., Leung, G. M., & Milton, D. K. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002691 · Cited by 496
Self-citationInhaling to mitigate exhaled bioaerosols
Edwards, D. A., Man, J. C., Brand, P., Katstra, J. P., Sommerer, K., Stone, H. A., Nardell, E., & Scheuch, G. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408159101 · Cited by 362
Droplet expulsion from the respiratory tract.
(1967) · PubMed · doi:10.1164/arrd.1967.95.3.435 · Cited by 240
Fabian, P., McDevitt, J. J., Lee, W.-M., Houseman, E. A., & Milton, D. K. (2009) · J. Environ. Monit. · doi:10.1039/b813520g · Cited by 49
Self-citation
Cited by
Respiratory virus shedding in exhaled breath and efficacy of face masks
Leung, N. H. L., Chu, D. K. W., Shiu, E. Y. C., Chan, K.-H., McDevitt, J. J., Hau, B. J. P., Yen, H.-L., Li, Y., Ip, D. K. M., Peiris, J. S. M., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0843-2 · Cited by 2,270
Self-citationAirborne transmission of respiratory viruses
Wang, C. C., Prather, K. A., Sznitman, J., Jimenez, J. L., Lakdawala, S. S., Tufekci, Z., & Marr, L. C. (2021) · Science · doi:10.1126/science.abd9149 · Cited by 1,543
Transmissibility and transmission of respiratory viruses
Leung, N. H. L. (2021) · Nature Reviews Microbiology · doi:10.1038/s41579-021-00535-6 · Cited by 890
Infectious virus in exhaled breath of symptomatic seasonal influenza cases from a college community
Yan, J., Grantham, M., Pantelic, J., Bueno de Mesquita, P. J., Albert, B., Liu, F., Ehrman, S., Milton, D. K., EMIT Consortium, Adamson, W., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1716561115 · Cited by 534
Self-citationAirborne spread of infectious agents in the indoor environment
Wei, J., & Li, Y. (2016) · American Journal of Infection Control · doi:10.1016/j.ajic.2016.06.003 · Cited by 519
Metadata
- Authors
- Fabian, P., Brain, J., Houseman, E. A., Gern, J., & Milton, D. K.
- Venue
- Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Publisher
- SAGE Publications
- Published
- 2011-03
- Volume
- 24
- Issue
- 3
- Pages
- 137-147
- ISSN
- 1941-2703 (ISSN-L)
- 1941-2711
- OpenAlex
- W1986741472
- Cited by
- 166
- References
- 5
- FWCI
- 2.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Origin of Exhaled Breath Particles from Healthy and Human Rhinovirus-Infected Subjects. https://app.cochat.ai/papers/10.1089/jamp.2010.0815
- The paper
- Fabian, P., Brain, J., Houseman, E. A., Gern, J., & Milton, D. K. (2011). Origin of Exhaled Breath Particles from Healthy and Human Rhinovirus-Infected Subjects. Journal of Aerosol Medicine and Pulmonary Drug Delivery. https://doi.org/10.1089/jamp.2010.0815
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.