The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Validation of the ‘Test of the Adherence to Inhalers’ (TAI) for Asthma and COPD Patients
Open accessAbstract
BACKGROUND: To validate the 'Test of Adherence to Inhalers' (TAI), a 12-item questionnaire designed to assess the adherence to inhalers in patients with COPD or asthma. METHODS: A total of 1009 patients with asthma or COPD participated in a cross-sectional multicenter study. Patients with electronic adherence ≥80% were defined as adherents. Construct validity, internal validity, and criterion validity were evaluated. Self-reported adherence was compared with the Morisky-Green questionnaire. RESULTS: Factor analysis study demonstrated two factors, factor 1 was coincident with TAI patient domain (items 1 to 10) and factor 2 with TAI health-care professional domain (items 11 and 12). The Cronbach's alpha was 0.860 and the test-retest reliability 0.883. TAI scores correlated with electronic adherence (ρ=0.293, p=0.01). According to the best cut-off for 10 items (score 50, area under the ROC curve 0.7), 569 (62.5%) patients were classified as non-adherents. The non-adherence behavior pattern was: erratic 527 (57.9%), deliberate 375 (41.2%), and unwitting 242 (26.6%) patients. As compared to Morisky-Green test, TAI showed better psychometric properties. CONCLUSIONS: The TAI is a reliable and homogeneous questionnaire to identify easily non-adherence and to classify from a clinical perspective the barriers related to the use of inhalers in asthma and COPD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coefficient Alpha and the Internal Structure of Tests
Cronbach, L. J. (1951) · Psychometrika · doi:10.1007/bf02310555 · Cited by 43,931
Miller, M. R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Crapo, R., Enright, P., van der Grinten, C. P. M., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034805 · Cited by 15,627
Concurrent and Predictive Validity of a Self-reported Measure of Medication Adherence
Morisky, D. E., Green, L. W., & Levine, D. M. (1986) · Medical Care · doi:10.1097/00005650-198601000-00007 · Cited by 5,317
A Second Generation Little Jiffy
Kaiser, H. F. (1970) · Psychometrika · doi:10.1007/bf02291817 · Cited by 4,785
Kaiser, H. F., & Rice, J. (1974) · Educational and Psychological Measurement · doi:10.1177/001316447403400115 · Cited by 3,423
Development of the asthma control test
Nathan, R. A., Sorkness, C. A., Kosinski, M., Schatz, M., Li, J. T., Marcus, P., Murray, J. J., & Pendergraft, T. B. (2004) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2003.09.008 · Cited by 2,906
The Delphi Method: An Experimental Study of Group Opinion
(1969) · RAND Corporation eBooks · doi:10.7249/rm5888 · Cited by 1,628
A systematic review of adherence with medications for diabetes
Cramer, J. A. (2004) · Diabetes Care · doi:10.2337/diacare.27.5.1218 · Cited by 1,203
Inhaler mishandling remains common in real life and is associated with reduced disease control
Melani, A. S., Bonavia, M., Cilenti, V., Cinti, C., Lodi, M., Martucci, P., Serra, M., Scichilone, N., Sestini, P., Aliani, M., et al. (2011) · Respiratory Medicine · doi:10.1016/j.rmed.2011.01.005 · Cited by 947
Effect of incorrect use of dry powder inhalers on management of patients with asthma and COPD
Lavorini, F., Magnan, A., Christophe Dubus, J., Voshaar, T., Corbetta, L., Broeders, M., Dekhuijzen, R., Sanchis, J., Viejo, J. L., Barnes, P., et al. (2008) · Respiratory Medicine · doi:10.1016/j.rmed.2007.11.003 · Cited by 609
Adherence to inhaled therapy, mortality and hospital admission in COPD
Vestbo, J., Anderson, J. A., Calverley, P. M. A., Celli, B., Ferguson, G. T., Jenkins, C., Knobil, K., Willits, L. R., Yates, J. C., & Jones, P. W. (2009) · Thorax · doi:10.1136/thx.2009.113662 · Cited by 516
Spirometric reference values from a Mediterranean population.
Roca, J., Sanchis, J., Agustí-Vidal, A., Segarra, F., Navajas, D., Rodríguez-Roisin, R., Casán, P., & Sans, S. (1986) · PubMed · Cited by 499
Relationship between adherence to inhaled corticosteroids and poor outcomes among adults with asthma
Williams, L. K., Pladevall, M., Xi, H., Peterson, E. L., Joseph, C., Lafata, J. E., Ownby, D. R., & Johnson, C. C. (2004) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2004.09.028 · Cited by 489
Properties of the COPD assessment test in a cross-sectional European study
Jones, P. W., Brusselle, G., Dal Negro, R. W., Ferrer, M., Kardos, P., Levy, M. L., Perez, T., Soler Cataluña, J. J., van der Molen, T., Adamek, L., et al. (2011) · European Respiratory Journal · doi:10.1183/09031936.00177210 · Cited by 341
Measuring Adherence to Asthma Medication Regimens
Rand, C. S., & Wise, R. A. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm/149.2_pt_2.s69 · Cited by 338
Metered-Dose Inhaler Adherence in a Clinical Trial
Rand, C. S., Wise, R. A., Nides, M., Simmons, M. S., Bleecker, E. R., Kusek, J. W., Li, V. C., & Tashkin, D. P. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/146.6.1559 · Cited by 302
Cohen, J. L., Mann, D. M., Wisnivesky, J. P., Horne, R., Leventhal, H., Musumeci-Szabó, T. J., & Halm, E. A. (2009) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)60532-7 · Cited by 235
[Assessment of the reliability of clinical findings: the intraclass correlation coefficient].
Prieto, L., Lamarca, R., & Casado, A. (1998) · PubMed · Cited by 211
Validation of the Spanish Version of the Asthma Control Test (ACT)
Vega, J. M., Badia, X., Badiola, C., López-Viña, A., Olaguíbel, J. M., Picado, C., Sastre, J., & Dal-Ré, R. (2007) · Journal of Asthma · doi:10.1080/02770900701752615 · Cited by 173
Self-citationBoulet, L.-P., Vervloet, D., Magar, Y., & Foster, J. M. (2012) · Clinics in Chest Medicine · doi:10.1016/j.ccm.2012.06.002 · Cited by 169
Jiménez, A. V., Ballestero, G. A., Visa, P. M., Ferré, M. L. F., & León Sanromá, M. (1992) · PubMed · Cited by 168
Determinants of Patient Adherence to an Aerosol Regimen
Rau, J. L. (2005) · Respiratory Care · doi:10.4187/respcare.05501346 · Cited by 135
Development of the ASK-20 Adherence Barrier Survey
Hahn, S. R., Park, J., Skinner, E. P., Yu-Isenberg, K. S., Weaver, M. B., Crawford, B., & Flowers, P. W. (2008) · Current Medical Research and Opinion · doi:10.1185/03007990802174769 · Cited by 130
Brooks, C. M., Richards, J. M., Kohler, C. L., Soong, S., Martin, B., Windsor, R. A., & Bailey, W. C. (1994) · Medical Care · doi:10.1097/00005650-199403000-00008 · Cited by 117
It’s the adherence, stupid (that determines asthma control in preschool children)!
Klok, T., Kaptein, A. A., Duiverman, E. J., & Brand, P. L. P. (2013) · European Respiratory Journal · doi:10.1183/09031936.00054613 · Cited by 92
Cecere, L. M., Slatore, C. G., Uman, J. E., Evans, L., Udris, E. M., Bryson, C. L., & Au, D. H. (2012) · COPD Journal of Chronic Obstructive Pulmonary Disease · doi:10.3109/15412555.2011.650241 · Cited by 92
Asthma control: importance of compliance and inhaler technique assessments
Baddar, S. A., Jayakrishnan, B., & Al-Rawas, O. A. (2013) · Journal of Asthma · doi:10.3109/02770903.2013.871558 · Cited by 87
The development of the ProMAS: a Probabilistic Medication Adherence Scale
Kleppe, M., Lacroix, J. P. W., Ham, J. R. C., & Midden, C. (2015) · Patient Preference and Adherence · doi:10.2147/ppa.s76749 · Cited by 62
McHorney, C. A., Spain, C. V., Alexander, C. M., & Simmons, J. B. (2009) · Clinical Therapeutics · doi:10.1016/j.clinthera.2009.11.030 · Cited by 62
In vitro evaluation of an asthma dosing device: The smart-inhaler
Burgess, S., Wilson, S., Cooper, D. M., Sly, P. D., & Devadason, S. G. (2005) · Respiratory Medicine · doi:10.1016/j.rmed.2005.09.004 · Cited by 59
Csako, G., McGriff, N. J., Rotman-Pikielny, P., Sarlis, N. J., & Pucino, F. (2001) · Annals of Pharmacotherapy · doi:10.1345/aph.1a031 · Cited by 40
Metadata
- Authors
- Plaza, V., Fernández-Rodríguez, C., Melero, C., Cosío, B. G., Entrenas, L. M., de Llano, L. P., Gutiérrez-Pereyra, F., Tarragona, E., Palomino, R., López-Viña, A., & on behalf of the TAI Study Group
- Venue
- Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Publisher
- SAGE Publications
- Published
- 2016-04
- Volume
- 29
- Issue
- 2
- Pages
- 142-152
- ISSN
- 1941-2703 (ISSN-L)
- 1941-2711
- OpenAlex
- W2121612376
- Cited by
- 284
- References
- 31
- FWCI
- 10.07
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.