Mechanical Characterization of the Injured Spinal Cord after Lateral Spinal Hemisection Injury in the Rat
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The glial scar formed at the site of traumatic spinal cord injury (SCI) has been classically hypothesized to be a potent physical and biochemical barrier to nerve regeneration. One longstanding hypothesis is that the scar acts as a physical barrier due to its increased stiffness in comparison to uninjured spinal cord tissue. However, the information regarding the mechanical properties of the glial scar in the current literature is mostly anecdotal and not well quantified. We monitored the mechanical relaxation behavior of injured rat spinal cord tissue at the site of mid-thoracic spinal hemisection 2 weeks and 8 weeks post-injury using a microindentation test method. Elastic moduli were calculated and a modified standard linear model (mSLM) was fit to the data to estimate the relaxation time constant and viscosity. The SLM was modified to account for a spectrum of relaxation times, a phenomenon common to biological tissues, by incorporating a stretched exponential term. Injured tissue exhibited significantly lower stiffness and elastic modulus in comparison to uninjured control tissue, and the results from the model parameters indicated that the relaxation time constant and viscosity of injured tissue were significantly higher than controls. This study presents direct micromechanical measurements of injured spinal cord tissue post-injury. The results of this study show that the injured spinal tissue displays complex viscoelastic behavior, likely indicating changes in tissue permeability and diffusivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Astrocyte activation and reactive gliosis
Pekny, M., & Nilsson, M. (2005) · Glia · doi:10.1002/glia.20207 · Cited by 1,611
The bright side of the glial scar in CNS repair
Rolls, A., Shechter, R., & Schwartz, M. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2591 · Cited by 674 · cited 1×
“…at the site of spinal cord injury is physiologically advantageous in the acute phase of injury, limiting the diffusion of neurotoxic agents out of the lesion site, thus providing neuroprotection (Fawcett and Asher, 1999; Renault-Mihara et al., 2008; Rolls et al., 2009; Silver and Miller, 2004).”
The role of extracellular matrix in CNS regeneration
Busch, S. A., & Silver, J. (2007) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2006.09.004 · Cited by 468 · cited 2×
“…characterized by other investigators, and our immunohistological findings are similar to those of several other studies reported in the literature (Busch and Silver, 2007; Fawcett and Asher, 1999; Hermanns et al., 2001; Klapka and Mu¨ller, 2006; Klapka et al., 2005; Siegenthaler et al., 2007;…”
Pekny, M., Johansson, C. B., Eliasson, C., Stakeberg, J., Wallén, Å., Perlmann, T., Lendahl, U., Betsholtz, C., Berthold, C.-H., & Frisén, J. (1999) · The Journal of Cell Biology · doi:10.1083/jcb.145.3.503 · Cited by 405 · cited 1×
“Additionally, Miller and colleagues (2009) hypothesized that reactive astrocytes could be a mechanically favorable substrate for neuronal regrowth and repair in the absence of other inhibitory factors (Pekny and Nilsson, 2005; Pekny et al.,1999).”
Cited by
The stiffness of living tissues and its implications for tissue engineering
Guimarães, C. F., Gasperini, L., Marques, A. P., & Reis, R. L. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0169-1 · Cited by 1,515
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
The soft mechanical signature of glial scars in the central nervous system
Moeendarbary, E., Weber, I. P., Sheridan, G. K., Koser, D. E., Soleman, S., Haenzi, B., Bradbury, E. J., Fawcett, J., & Franze, K. (2017) · Nature Communications · doi:10.1038/ncomms14787 · Cited by 406
Relationship between intracortical electrode design and chronic recording function
Karumbaiah, L., Saxena, T., Carlson, D., Patil, K., Patkar, R., Gaupp, E. A., Betancur, M., Stanley, G. B., Carin, L., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.016 · Cited by 241
Self-citationChondroitin sulfate glycosaminoglycan hydrogels create endogenous niches for neural stem cells
Karumbaiah, L., Enam, S. F., Brown, A. C., Saxena, T., Betancur, M. I., Barker, T. H., & Bellamkonda, R. V. (2015) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.5b00397 · Cited by 73
Self-citation
Metadata
- Authors
- Saxena, T., Gilbert, J., Stelzner, D., & Hasenwinkel, J.
- Venue
- Journal of Neurotrauma
- Publisher
- SAGE Publications
- Published
- 2012-06-10
- Volume
- 29
- Issue
- 9
- Pages
- 1747-1757
- ISSN
- 0897-7151 (ISSN-L)
- 1557-9042
- OpenAlex
- W2149090625
- Cited by
- 52
- References
- 4
- FWCI
- 3.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.