The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Photobiomodulation on the Angiogenesis of Skin Wounds in Rats Using Different Light Sources
Abstract
Objective: The aim of this study was to compare the angiogenic effects of laser and light-emitting diode (LED) illumination on wounds induced in rats, with varied fluence. Background Data: The LED is an alternative light source that accelerates wound healing, and its efficiency concerning the angiogenic effect was compared to low-level laser therapy (LLLT). Methods: The experimental model consisted of a circular wound inflicted on the quadriceps of 120 rats, using a 15-mm-diameter "punch." Animals were divided randomly into five groups: two groups of laser, with dosages of 5 and 20 J/cm 2 , respectively, two groups of LED, also with dosages of 5 and 20 J/cm 2 , and a control group. Six hours after wound infliction, the treated groups received the diverse applications accordingly and were irradiated every 24 h. Angiogenesis was studied through histomorphometry on days 3, 7, 14, and 21 after the wounds were inflicted. Results: On days 3, 7, and 14, the proliferation of blood vessels in all irradiated groups was superior in comparison to those of the control group( p < 0.05). Treatment with fluence of 5 J/cm 2 was better than the laser group with 20 J/cm 2 on day 21. Conclusion: Red LLLT and LED demonstrated expressive results in angiogenesis. Light coherence was shown not to be essential to angiogenesis. However, further studies are needed in order to investigate the photobiomodulatory effects of LED in relation to LLLT in various biological tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue oxygenation, anemia, and perfusion in relation to wound healing in surgical patients.
JONSSON, K., JENSEN, J. A., GOODSON, W. H., SCHEUENSTUHL, H., WEST, J., HOPF, H. W., & HUNT, T. K. (1991) · Annals of Surgery · doi:10.1097/00000658-199111000-00011 · Cited by 462
Cited by
Biphasic Dose Response in Low Level Light Therapy
Huang, Y.-Y., Chen, A. C.-H., Carroll, J. D., & Hamblin, M. R. (2009) · Dose-Response · doi:10.2203/dose-response.09-027.hamblin · Cited by 1,162
Kim, R.-H., Kim, D.-H., Xiao, J., Kim, B. H., Park, S.-I., Panilaitis, B., Ghaffari, R., Yao, J., Li, M., Liu, Z., et al. (2010) · Nature Materials · doi:10.1038/nmat2879 · Cited by 637
Effects of low-power light therapy on wound healing: LASER x LED
Chaves, M. E. D. A., Araújo, A. R. D., Piancastelli, A. C. C., & Pinotti, M. (2014) · Anais Brasileiros de Dermatologia · doi:10.1590/abd1806-4841.20142519 · Cited by 282
Peng, Q., Juzeniene, A., Chen, J., Svaasand, L. O., Warloe, T., Giercksky, K.-E., & Moan, J. (2008) · Reports on Progress in Physics · doi:10.1088/0034-4885/71/5/056701 · Cited by 255
Tim, C. R., Bossini, P. S., Kido, H. W., Malavazi, I., von Zeska Kress, M. R., Carazzolle, M. F., Parizotto, N. A., & Rennó, A. C. (2016) · Journal of Photochemistry and Photobiology B Biology · doi:10.1016/j.jphotobiol.2015.10.028 · Cited by 76
Metadata
- Authors
- Corazza, A. V., Jorge, J., Kurachi, C., & Bagnato, V. S.
- Venue
- Photomedicine and Laser Surgery
- Publisher
- SAGE Publications
- Published
- 2007-04
- Volume
- 25
- Issue
- 2
- Pages
- 102-106
- ISSN
- 1549-5418 (ISSN-L)
- 1557-8550
- OpenAlex
- W1999927166
- Cited by
- 245
- References
- 1
- FWCI
- 7.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.