Novel Design of a Soft Lightweight Pneumatic Continuum Robot Arm with Decoupled Variable Stiffness and Positioning
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Soft robot arms possess unique capabilities when it comes to adaptability, flexibility, and dexterity. In addition, soft systems that are pneumatically actuated can claim high power-to-weight ratio. One of the main drawbacks of pneumatically actuated soft arms is that their stiffness cannot be varied independently from their end-effector position in space. The novel robot arm physical design presented in this article successfully decouples its end-effector positioning from its stiffness. An experimental characterization of this ability is coupled with a mathematical analysis. The arm combines the light weight, high payload to weight ratio and robustness of pneumatic actuation with the adaptability and versatility of variable stiffness. Light weight is a vital component of the inherent safety approach to physical human-robot interaction. To characterize the arm, a neural network analysis of the curvature of the arm for different input pressures is performed. The curvature-pressure relationship is also characterized experimentally.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A general regression neural network
Specht, D. F. (1991) · IEEE Transactions on Neural Networks · doi:10.1109/72.97934 · Cited by 4,492
Orthogonal least squares learning algorithm for radial basis function networks
Chen, S., Cowan, C. F. N., & Grant, P. M. (1991) · IEEE Transactions on Neural Networks · doi:10.1109/72.80341 · Cited by 3,362
Artificial neural networks: fundamentals, computing, design, and application
Basheer, I. A., & Hajmeer, M. (2000) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(00)00201-3 · Cited by 3,231 · cited 1×
“A detailed review of NN can be found in [31].”
BackgroundSoft Robotics: Biological Inspiration, State of the Art, and Future Research
Trivedi, D., Rahn, C. D., Kier, W. M., & Walker, I. D. (2008) · Applied Bionics and Biomechanics · doi:10.1080/11762320802557865 · Cited by 1,708
Universal robotic gripper based on the jamming of granular material
Brown, E., Rodenberg, N., Amend, J., Mozeika, A., Steltz, E., Zakin, M. R., Lipson, H., & Jaeger, H. M. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1003250107 · Cited by 1,603
Measurement and modeling of McKibben pneumatic artificial muscles
Chou, C.-P., & Hannaford, B. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.481753 · Cited by 1,589
2021 IEEE International Conference on Robotics and Automation (ICRA)
(2021) · doi:10.1109/icra48506.2021 · Cited by 1,039
Variable impedance actuators: A review
Vanderborght, B., Albu-Schaeffer, A., Bicchi, A., Burdet, E., Caldwell, D. G., Carloni, R., Catalano, M., Eiberger, O., Friedl, W., Ganesh, G., et al. (2013) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2013.06.009 · Cited by 1,008
Soft Robotic Grippers for Biological Sampling on Deep Reefs
Galloway, K. C., Becker, K. P., Phillips, B., Kirby, J., Licht, S., Tchernov, D., Wood, R. J., & Gruber, D. F. (2016) · Soft Robotics · doi:10.1089/soro.2015.0019 · Cited by 848 · cited 2×
“DFCA¼ 3PCA 4nCA2p LCAn 2 LCA02 (19) Similarly, DFCB¼ 3PCB 4nCB2p LCBn 2 LCB02 (20) DFE¼ 3PE 4nE2p LEn 2 LE02 (21) These are the amounts of external force to be applied to each muscle to achieve the deflection shown in the loaded case.”
Mechanical Programming of Soft Actuators by Varying Fiber Angle
Connolly, F., Polygerinos, P., Walsh, C. J., & Bertoldi, K. (2015) · Soft Robotics · doi:10.1089/soro.2015.0001 · Cited by 522
Modelling of the McKibben artificial muscle: A review
Tondu, B. (2012) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x11435435 · Cited by 490 · cited 4×
“If this manipulator is now moved to position rEncn with the same displacement d used in the previous example, each muscle will again change length to LCAn, LCBn, and LEn, respectively, and the amount of force they are each now generating is again described by Equations (19–21).”
BackgroundInfluentialRequirements for Safe Robots: Measurements, Analysis and New Insights
Haddadin, S., Albu-Schäffer, A., & Hirzinger, G. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364909343970 · Cited by 444 · cited 3×
“For example, the same arm length can be obtained (1) in a low stiffness configuration by inflating the expanding muscle and the internal parallel array of contractors and keeping the external array of contractors deflated and (2) in a high stiffness configuration by increasing the internal pressure of the expanding mu…”
BackgroundMethodA New Approach to Modeling Hysteresis in a Pneumatic Artificial Muscle Using The Maxwell-Slip Model
Minh, T. V., Tjahjowidodo, T., Ramón, H., & BRUSSEL, H. V. (2010) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2009.2038373 · Cited by 285
Safety Evaluation Method of Design and Control for Human-Care Robots
Ikuta, K., Ishii, H., & Nokata, M. (2003) · The International Journal of Robotics Research · doi:10.1177/027836403128965079 · Cited by 239
Enhanced Modelling and Performance in Braided Pneumatic Muscle Actuators
Davis, S., Tsagarakis, N., Canderle, J., & Caldwell, D. G. (2003) · The International Journal of Robotics Research · doi:10.1177/027836403128964908 · Cited by 177
Self-citationBraid Effects on Contractile Range and Friction Modeling in Pneumatic Muscle Actuators
Davis, S., & Caldwell, D. G. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906063227 · Cited by 162
Self-citationVariable Stiffness Structures Utilizing Fluidic Flexible Matrix Composites
Shan, Y., Philen, M. K., Lotfi, A., Li, S., Bakis, C. E., Rahn, C. D., & Wang, K. (2008) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x08095270 · Cited by 125
A variable compliance, soft gripper
Giannaccini, M. E., Georgilas, I. P., Horsfield, I., Peiris, B., Lenz, A., Pipe, T., & Dogramadzi, S. (2013) · Autonomous Robots · doi:10.1007/s10514-013-9374-8 · Cited by 117
Self-citationTiwari, R., Meller, M. A., Wajcs, K. B., Moses, C., Reveles, I., & Garcia, E. (2012) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x12438627 · Cited by 107 · cited 2×
“Hydraulic pMAs are reported in Tiwari et al.18 and Shan et al.19 High bulk modulus fluids have the disadvantage of increasing the weight of the structure considerably, a considerable problem unless they are used in underwater robots.20 The novel robot arm physical design presented in this work combines the light weigh…”
BackgroundSantiago, J. L. C., Godage, I. S., Gonthina, P. S., & Walker, I. D. (2016) · Soft Robotics · doi:10.1089/soro.2015.0021 · Cited by 98
Soft Robotics on the Move: Scientific Networks, Activities, and Future Challenges
Nurzaman, S. G., Fumiya Iida, A., Margheri, L., & Laschi, C. (2014) · Soft Robotics · doi:10.1089/soro.2014.0012 · Cited by 33
Biohybrid Control of General Linear Systems Using the Adaptive Filter Model of Cerebellum
Wilson, E. D., Assaf, T., Pearson, M. J., Rossiter, J. M., Dean, P., Anderson, S., & Porrill, J. (2015) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2015.00005 · Cited by 17
Cited by
Soft Robotic Manipulators: Designs, Actuation, Stiffness Tuning, and Sensing
Dou, W., Zhong, G., Cao, J., Shi, Z., Peng, B., & Jiang, L. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202100018 · Cited by 237
Metadata
- Authors
- Giannaccini, M. E., Xiang, C., Atyabi, A., Theodoridis, T., Nefti-Meziani, S., & Davis, S.
- Venue
- Soft Robotics
- Publisher
- SAGE Publications
- Published
- 2018-02
- Volume
- 5
- Issue
- 1
- Pages
- 54-70
- ISSN
- 2169-5172 (ISSN-L)
- 2169-5180
- OpenAlex
- W2746200739
- Cited by
- 166
- References
- 24
- FWCI
- 4.19
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.