The DOI matches its Crossref record.
Cyclic Mechanical Preconditioning Improves Engineered Muscle Contraction
Abstract
The inability to engineer clinically relevant functional muscle tissue remains a major hurdle to successful skeletal muscle reconstructive procedures. This article describes an in vitro preconditioning protocol that improves the contractility of engineered skeletal muscle after implantation in vivo. Primary human muscle precursor cells (MPCs) were seeded onto collagen-based acellular tissue scaffolds and subjected to cyclic strain in a computer-controlled bioreactor system. Control constructs (static culture conditions) were run in parallel. Bioreactor preconditioning produced viable muscle tissue constructs with unidirectional orientation within 5 days, and in vitro-engineered constructs were capable of generating contractile responses after 3 weeks of bioreactor preconditioning. MPC-seeded constructs preconditioned in the bioreactor for 1 week were also implanted onto the latissimus dorsi muscle of athymic mice. Analysis of tissue constructs retrieved 1 to 4 weeks postimplantation showed that bioreactor-preconditioned constructs, but not statically cultured control tissues, generated tetanic and twitch contractile responses with a specific force of 1% and 10%, respectively, of that observed on native latissimus dorsi. To our knowledge, this is the largest force generated for tissue-engineered skeletal muscle on an acellular scaffold. This finding has important implications to the application of tissue engineering and regenerative medicine to skeletal muscle replacement and reconstruction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mechanical forces direct stem cell behaviour in development and regeneration
Vining, K. H., & Mooney, D. J. (2017) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.108 · Cited by 1,656
Choi, J. S., Lee, S. J., Christ, G. J., Atala, A., & Yoo, J. J. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.031 · Cited by 611
Self-citationNanoparticles in tissue engineering: applications, challenges and prospects
Hasan, A., Morshed, M., Memic, A., Hassan, S., Webster, T., & Marei, H. (2018) · International Journal of Nanomedicine · doi:10.2147/ijn.s153758 · Cited by 496
Biomaterials for Integration with 3-D Bioprinting
Skardal, A., & Atala, A. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1207-1 · Cited by 474
Self-citationQazi, T. H., Mooney, D. J., Pumberger, M., Geißler, S., & Duda, G. N. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.110 · Cited by 433
Metadata
- Authors
- Moon, D. G., Christ, G., Stitzel, J. D., Atala, A., & Yoo, J. J.
- Venue
- Tissue Engineering Part A
- Publisher
- SAGE Publications
- Published
- 2008-04
- Volume
- 14
- Issue
- 4
- Pages
- 473-482
- ISSN
- 1937-3341 (ISSN-L)
- 1937-335X
- OpenAlex
- W1998646921
- Cited by
- 202
- References
- 0
- FWCI
- 10.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cyclic Mechanical Preconditioning Improves Engineered Muscle Contraction. https://app.cochat.ai/papers/10.1089/tea.2007.0104
- The paper
- Moon, D. G., Christ, G., Stitzel, J. D., Atala, A., & Yoo, J. J. (2008). Cyclic Mechanical Preconditioning Improves Engineered Muscle Contraction. Tissue Engineering Part A. https://doi.org/10.1089/tea.2007.0104
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.