Increased Vascularization and Heterogeneity of Vascular Structures Occurring in Polyglycolide Matrices Containing Aortic Endothelial Cells Implanted in the Rat
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The development of sufficient vascularization to maintain adequate perfusion is a primary consideration in the engineering of large tissue constructs. This research investigated the ability of aortic endothelial cells to affect the organization of vascular structures within a matrix both in vitro and in vivo. Highly porous matrices of poly(glycolic) acid (PGA) (50 mg/cc) 10 × 10 × 3 mm meshes were implanted subcutaneously (two per rat) in inbred rats, with and without syngeneic cells. Test groups (n = 8/group) were: PGA; PGA with aortic endothelial cells; PGA with aortic smooth muscle cells; PGA with skeletal muscle cells. Matrices were evaluated histologically from two rats per week at weeks 1,2,3, and 4. Scanning electron microscopy was done on matrices prior to implantation. Matrices without cells demonstrated typical ingrowth of host fibroblasts, capillaries, and macrophages/giant cells. Matrices containing skeletal muscle or aortic smooth muscle cells showed similar vascularization to matrices without cells. The implanted muscle cells demonstrated cellular growth with little organization. Matrices containing aortic endothelial cells demonstrated organized and unorganized endothelial cells within the matrix, increased numbers of capillaries, increased numbers of lymphatic-like structures, and numerous heterogeneous and unusual vascular structures which were positive for factor VIII localization including: 1) large parallel arrays of capillaries, 2) large thin sinusoidal vascular structures, and 3) layered complex vascular structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomaterials in Tissue Engineering
Hubbell, J. A. (1995) · Nature Biotechnology · doi:10.1038/nbt0695-565 · Cited by 1,060
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722
Cited by
Biomaterial developments for bone tissue engineering
Burg, K. J. L., Porter, S., & Kellam, J. F. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00102-2 · Cited by 1,643
Self-citationDevelopment of biocompatible synthetic extracellular matrices for tissue engineering
Kim, B.-S., & Mooney, D. J. (1998) · Trends in Biotechnology · doi:10.1016/s0167-7799(98)01191-3 · Cited by 931
Self-citationRapid prototyping in tissue engineering: challenges and potential
Yeong, W.-Y., Chua, C.-K., Leong, K.-F., & Chandrasekaran, M. (2004) · Trends in Biotechnology · doi:10.1016/j.tibtech.2004.10.004 · Cited by 807
Host response to tissue engineered devices
Babensee, J. E., Anderson, J. M., McIntire, L. V., & Mikos, A. G. (1998) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00023-4 · Cited by 585
Angiogenesis in Tissue Engineering: Breathing Life into Constructed Tissue Substitutes
Laschke, M. W., Harder, Y., Amon, M., Martin, I., Farhadi, J., Ring, A., Torio-Padron, N., Schramm, R., Rücker, M., Junker, D., et al. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2093 · Cited by 546
Metadata
- Authors
- Holder, W. D., Gruber, H. E., Roland, W. D., Moore, A. L., Culberson, C. R., Loebsack, A. B., Burg, K. J. L., & Mooney, D. J.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 1997-06
- Volume
- 3
- Issue
- 2
- Pages
- 149-160
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2089122164
- Cited by
- 68
- References
- 2
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.