CoChat

Increased Vascularization and Heterogeneity of Vascular Structures Occurring in Polyglycolide Matrices Containing Aortic Endothelial Cells Implanted in the Rat

Open access
Holder, Walter D., Gruber, Helen E., Roland, Wendy D., Moore, Alecia L., Culberson, Catherine R., Loebsack, Anna B., Burg, Karen J.L., Mooney, David J. · 1997 · Tissue Engineering
Cited by 68

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The development of sufficient vascularization to maintain adequate perfusion is a primary consideration in the engineering of large tissue constructs. This research investigated the ability of aortic endothelial cells to affect the organization of vascular structures within a matrix both in vitro and in vivo. Highly porous matrices of poly(glycolic) acid (PGA) (50 mg/cc) 10 × 10 × 3 mm meshes were implanted subcutaneously (two per rat) in inbred rats, with and without syngeneic cells. Test groups (n = 8/group) were: PGA; PGA with aortic endothelial cells; PGA with aortic smooth muscle cells; PGA with skeletal muscle cells. Matrices were evaluated histologically from two rats per week at weeks 1,2,3, and 4. Scanning electron microscopy was done on matrices prior to implantation. Matrices without cells demonstrated typical ingrowth of host fibroblasts, capillaries, and macrophages/giant cells. Matrices containing skeletal muscle or aortic smooth muscle cells showed similar vascularization to matrices without cells. The implanted muscle cells demonstrated cellular growth with little organization. Matrices containing aortic endothelial cells demonstrated organized and unorganized endothelial cells within the matrix, increased numbers of capillaries, increased numbers of lymphatic-like structures, and numerous heterogeneous and unusual vascular structures which were positive for factor VIII localization including: 1) large parallel arrays of capillaries, 2) large thin sinusoidal vascular structures, and 3) layered complex vascular structures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/ten.1997.3.149

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Holder, W. D., Gruber, H. E., Roland, W. D., Moore, A. L., Culberson, C. R., Loebsack, A. B., Burg, K. J. L., & Mooney, D. J.
Venue
Tissue Engineering
Published
1997-06
Volume
3
Issue
2
Pages
149-160
ISSN
  • 1076-3279 (ISSN-L)
  • 1557-8690
OpenAlex
W2089122164
Cited by
68
References
2
FWCI
4.97
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.