Biodegradable Implants for the Treatment of Osteochondral Defects in a Goat Model
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Full-thickness, circular, 7 × 7 mm, osteochondral defects were created in the weight-bearing aspect of the medial femoral condyle in skeletally mature female Spanish goats. Four treatment approaches were used to manage the osteochondral defects. Defects were left (a) empty (negative control), (b) filled with a two-phase biodegradable polymeric implant, (c) filled with the implant plus 180 ng transforming growth factor beta (TGFβ), or (d) filled with the implant plus 1,800 ng TGFβ. At 16 weeks following surgery, resurfacing of osteochondral defects was found to be incomplete in all groups. Biomechanical and histologic evaluation of the neocartilage showed that slightly better quality repair was promoted by the two implant groups containing TGFβ. The use of the two-phase biodegradable implant for delivering TGFβ seems to be beneficial insofar as structural quality of subchondral bone is concerned, although even in these two groups new cartilage did not fill the defects completely.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elevated temperature degradation of a 50:50 copolymer of PLA-PGA
Agrawal, C. M., Huang, D., Schmitz, J. P., & Athanasiou, K. A. (1997) · Tissue Engineering · doi:10.1089/ten.1997.3.345 · Cited by 120
Self-citation
Cited by
Poly(lactic acid) modifications
Rasal, R. M., Janorkar, A. V., & Hirt, D. E. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.12.003 · Cited by 2,204
Application of chitosan-based polysaccharide biomaterials in cartilage tissue engineering: a review
Francis Suh, J.-K., & Matthew, H. W. T. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00126-5 · Cited by 1,997
Recent Developments in Ring Opening Polymerization of Lactones for Biomedical Applications
Albertsson, A.-C., & Varma, I. K. (2003) · Biomacromolecules · doi:10.1021/bm034247a · Cited by 1,582
Review: tissue engineering for regeneration of articular cartilage
Temenoff, J. S., & Mikos, A. G. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00213-6 · Cited by 1,052
Biodegradable polymeric scaffolds for musculoskeletal tissue engineering
Agrawal, C. M., & Ray, R. B. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200105)55:2<141::aid-jbm1000>3.0.co;2-j · Cited by 1,052
Metadata
- Authors
- Athanasiou, K., Korvick, D., & Schenck, R.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 1997-12
- Volume
- 3
- Issue
- 4
- Pages
- 363-373
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2047732103
- Cited by
- 80
- References
- 1
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biodegradable Implants for the Treatment of Osteochondral Defects in a Goat Model. https://app.cochat.ai/papers/10.1089/ten.1997.3.363
- The paper
- Athanasiou, K., Korvick, D., & Schenck, R. (1997). Biodegradable Implants for the Treatment of Osteochondral Defects in a Goat Model. Tissue Engineering. https://doi.org/10.1089/ten.1997.3.363
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.