Polymer Substrate Topography Actively Regulates the Multicellular Organization and Liver-Specific Functions of Cultured Hepatocytes
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This study examines the role of topography of porous synthetic polymer substrates in regulating the tissue-specific morphogenesis of cultured hepatocytes. Porous foams of amorphous 50/50 poly(D,L glycolic-co-lactic acid) (PGLA) with a wide range of controlled pore-size distributions ( approximately 1 to 100 microm) were used as culture model surfaces. We found that the induction of microporosity in PGLA substrates significantly improved cell attachment and viability in comparison to those observed on non-porous PGLA films. A detailed evaluation of cellular morphogenesis on the microporous matrices showed that hepatocellular organization was sensitively dependent on the topographical feature size of the foam surfaces. Foams with subcellular size voids ( approximately 3 microm) induced kinetics of two-dimensional hepatocyte reorganization, yet limited the extent of three-dimensional aggregation. In contrast, foams with supercellular size voids ( approximately 67-microm) restricted hepatocyte motility, thereby promoting the kinetics of 3D aggregation. At intermediate void sizes ( approximately 17 microm), both 2D and 3D reorganization kinetics were promoted. Albumin secretory kinetics progressively increased on all void size configurations, the most rapid and sustained kinetics observed in supercellular sized voids, which may serve to minimize cell-polymer contacts and maximize cell-cell contacts in 3D. Overall, these studies demonstrate that void topography of porous polymer substrates is a critical textural feature to induce short-term cell adhesion and viability, and to also selectively regulate the kinetics and extent of multicellular spreading versus 3D aggregation. By virtue of its effects on cell adhesion and morphogenesis, the void topography of nonphysiological polymer scaffolds also is a powerful variable to microengineer hepatospecific activity of tissue analogs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Engineering cell shape and function
Singhvi, R., Kumar, A., Lopez, G. P., Stephanopoulos, G. N., Wang, D. I. C., Whitesides, G. M., & Ingber, D. E. (1994) · Science · doi:10.1126/science.8171320 · Cited by 1,453
de Groot, J. H., Nijenhuis, A. J., Bruin, P., Pennings, A. J., Veth, R. P. H., Klompmaker, J., & Jansen, H. W. B. (1990) · Colloid and Polymer Science · doi:10.1007/bf01410672 · Cited by 81
Cited by
Godoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280
Cell proliferation and migration in silk fibroin 3D scaffolds
Mandal, B. B., & Kundu, S. C. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.02.006 · Cited by 583
Functionalizing PLGA and PLGA Derivatives for Drug Delivery and Tissue Regeneration Applications
Martins, C., Sousa, F., Araújo, F., & Sarmento, B. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701035 · Cited by 362
Zmora, S., Glicklis, R., & Cohen, S. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00146-1 · Cited by 297
Design of artificial extracellular matrices for tissue engineering
Kim, B.-S., Park, I.-K., Hoshiba, T., Jiang, H.-L., Choi, Y.-J., Akaike, T., & Cho, C.-S. (2011) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.10.001 · Cited by 296
Metadata
- Authors
- Ranucci, C. S., & Moghe, P. V.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 1999-10
- Volume
- 5
- Issue
- 5
- Pages
- 407-420
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2044021612
- Cited by
- 91
- References
- 2
- FWCI
- 3.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.