The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Grafting of Gelatin on Electrospun Poly(caprolactone) Nanofibers to Improve Endothelial Cell Spreading and Proliferation and to Control Cell Orientation
Abstract
We modified the surface of electrospun poly(caprolactone) (PCL) nanofibers to improve their compatibility with endothelial cells (ECs) and to show the potential application of PCL nanofibers as a blood vessel tissue-engineering scaffold. Nonwoven PCL nanofibers (PCL NF) and aligned PCL nanofibers (APCL NF) were fabricated by electrospinning technology. To graft gelatin on the nanofiber surface, PCL nanofibers were first treated with air plasma to introduce -COOH groups on the surface, followed by covalent grafting of gelatin molecules, using water-soluble carbodiimide as the coupling agent. The chemical change in the material surface during surface modification was confirmed by X-ray photoelectron spectroscopy and quantified by colorimetric methods. ECs were cultured to evaluate the cytocompatibility of surface-modified PCL NF and APCL NF. Gelatin grafting can obviously enhance EC spreading and proliferation compared with the original material. Moreover, gelatin-grafted APCL NF readily orients ECs along the fibers whereas unmodified APCL NF does not. Immunostaining micrographs showed that ECs cultured on gelatin-grafted PCL NF were able to maintain the expression of three characteristic markers: platelet-endothelial cell adhesion molecule 1 (PECAM-1), intercellular adhesion molecule 1 (ICAM-1), and vascular cell adhesion molecule 1 (VCAM-1). The surface-modified PCL nanofibrous material is a potential candidate material in blood vessel tissue engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A biodegradable nanofiber scaffold by electrospinning and its potential for bone tissue engineering
Yoshimoto, H., Shin, Y. M., Terai, H., & Vacanti, J. P. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00635-x · Cited by 1,977
Introduction to Colloid and Surface Chemistry
(1992) · Elsevier eBooks · doi:10.1016/c2009-0-24070-0 · Cited by 1,856
Yang, F., Murugan, R., Wang, S., & Ramakrishna, S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.051 · Cited by 1,804
Self-citationEffects of synthetic micro- and nano-structured surfaces on cell behavior
Flemming, R. G., Murphy, C. J., Abrams, G. A., Goodman, S. L., & Nealey, P. F. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00209-9 · Cited by 1,450
Aligned biodegradable nanofibrous structure: a potential scaffold for blood vessel engineering
Xu, C. Y., Inai, R., Kotaki, M., & Ramakrishna, S. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00593-3 · Cited by 1,213
Self-citationMo, X. M., Xu, C. Y., Kotaki, M., & Ramakrishna, S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.042 · Cited by 803
Self-citationAlbelda, S. M., Muller, W. A., Buck, C. A., & Newman, P. J. (1991) · The Journal of cell biology · doi:10.1083/jcb.114.5.1059 · Cited by 716
Li, W., Danielson, K. G., Alexander, P. G., & Tuan, R. S. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10101 · Cited by 536
Biomaterials in the development and future of vascular grafts
Xue, L., & Greisler, H. P. (2003) · Journal of Vascular Surgery · doi:10.1067/mva.2003.88 · Cited by 519
Xu, C., Inai, R., Kotaki, M., & Ramakrishna, S. (2004) · Tissue Engineering · doi:10.1089/1076327041887736 · Cited by 399
Self-citationOppenheimer-Marks, N., Davis, L. S., Bogue, D. T., Ramberg, J., & Lipsky, P. E. (1991) · The Journal of Immunology · doi:10.4049/jimmunol.147.9.2913 · Cited by 387
Contractile cardiac grafts using a novel nanofibrous mesh
Shin, M., Ishii, O., Sueda, T., & Vacanti, J. P. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.055 · Cited by 359
Biological surface engineering: a simple system for cell pattern formation
Zhang, S., Yan, L., Altman, M., Lässle, M., Nugent, H., Frankel, F., Lauffenburger, D. A., Whitesides, G. M., & Rich, A. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00014-9 · Cited by 344
Deutsch, M., Meinhart, J., Fischlein, T., Preiss, P., & Zilla, P. (1999) · Surgery · doi:10.1016/s0039-6060(99)70025-5 · Cited by 322
Tissue engineering of vascular grafts
Ratcliffe, A. (2000) · Matrix Biology · doi:10.1016/s0945-053x(00)00080-9 · Cited by 290
Correlation of endothelial cell shape and wall shear stress in a stenosed dog aorta.
Levesque, M. J., Liepsch, D., Moravec, S., & Nerem, R. M. (1986) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.6.2.220 · Cited by 242
Immobilization of proteins on poly(methyl methacrylate) films
Kang, I., Kwon, B. K., Lee, J. H., & Lee, H. B. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90045-4 · Cited by 147
Ying, L., Yin, C. N., Zhuo, R. ‐., Leong, K. W., Mao, H., Kang, E. T., & Neoh, K. G. (2002) · Biomacromolecules · doi:10.1021/bm025676w · Cited by 141
Jarrell, B. E., Williams, S. K., Stokes, G. K., Hubbard, F. A., Carabasi, R. A., Koolpe, E., Greener, D. A., Pratt, K. J., Moritz, M. J., & Radomski, J. S. (1986) · PubMed · Cited by 134
Spargo, B. J., Testoff, M. A., Nielsen, T. B., Stenger, D. A., Hickman, J. J., & Rudolph, A. S. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.23.11070 · Cited by 123
Contact guidance induced organization of extracellular matrix
Manwaring, M. E., Walsh, J. F., & Tresco, P. A. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.043 · Cited by 118
Tang, Y. W., Labow, R. S., & Santerre, J. P. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00563-x · Cited by 109
Microchannel Platform for the Study of Endothelial Cell Shape and Function
Gray, B. L., Lieu, D. K., Collins, S. D., Smith, R. L., & Barakat, A. I. (2002) · Biomedical Microdevices · doi:10.1023/a:1014211627166 · Cited by 87
Gümüşderelı́oğlu, M., & Şaşmazel, H. T. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00128-x · Cited by 82
An Apparatus to Study the Response of Cultured Endothelium to Shear Stress
Viggers, R. F., Wechezak, A. R., & Sauvage, L. R. (1986) · Journal of Biomechanical Engineering · doi:10.1115/1.3138624 · Cited by 64
Adhesive protein expression on human endothelial cells after in vitro contact with woven Dacron
Granchi, D., Cenni, E., Verri, E., Ciapetti, G., Gori, A., Gamberini, S., Leo, A. D., & Pizzoferrato, A. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00161-0 · Cited by 37
Jarrell, B. E., & Williams, S. K. (1991) · Journal of Vascular Surgery · doi:10.1016/0741-5214(91)90366-3 · Cited by 16
Cited by
Electrospinning: A fascinating fiber fabrication technique
Bhardwaj, N., & Kundu, S. C. (2010) · Biotechnology Advances · doi:10.1016/j.biotechadv.2010.01.004 · Cited by 5,028
Electrospinning: A Fascinating Method for the Preparation of Ultrathin Fibers
Greiner, A., & Wendorff, J. H. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604646 · Cited by 4,241
Electrospinning: Applications in drug delivery and tissue engineering
Sill, T. J., & von Recum, H. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.01.011 · Cited by 3,289
Haider, A., Haider, S., & Kang, I.-K. (2018) · Arabian Journal of Chemistry · doi:10.1016/j.arabjc.2015.11.015 · Cited by 1,861
Electrospun poly(ɛ-caprolactone)/gelatin nanofibrous scaffolds for nerve tissue engineering
Ghasemi-Mobarakeh, L., Prabhakaran, M. P., Morshed, M., Nasr-Esfahani, M.-H., & Ramakrishna, S. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.08.007 · Cited by 1,152
Self-citation
Metadata
- Authors
- Ma, Z., He, W., Yong, T., & Ramakrishna, S.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2005-07
- Volume
- 11
- Issue
- 7-8
- Pages
- 1149-1158
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W1981791383
- Cited by
- 477
- References
- 27
- FWCI
- 7.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.