The DOI matches its Crossref record.
Diffusion Limits of an in Vitro Thick Prevascularized Tissue
Abstract
Although tissue engineering promises to replace or restore lost function to nearly every tissue in the body, successful applications are currently limited to tissue less than 2 mm in thickness. in vivo capillary networks deliver oxygen and nutrients to thicker (> 2 mm) tissues, suggesting that introduction of a preformed in vitro vascular network may be a useful strategy for engineered tissues. This article describes a system for generating capillary-like networks within a thick fibrin matrix. Human umbilical vein endothelial cells, growing on the surface of microcarrier beads, were embedded in fibrin gels a known distance (Delta = 1.8-4.5 mm) from a monolayer of human dermal fibroblasts. The distance of the growth medium, which contained vascular endothelial growth factor and basic fibroblast growth factor, from the beads, C, was varied from 2.7 to 7.2 mm. Capillaries with visible lumens sprouted in 2-3 days, reaching lengths that exceeded 500 microm within 6-8 days. On day 7, capillary network formation was largely independent of C; however, a strong inverse correlation with Delta was observed, with the maximum network formation at Delta = 1.8 mm. Surprisingly, the thickness of the gel was not a limiting factor for oxygen diffusion as these tissue constructs retained a relatively high oxygen tension of > 125 mmHg. We conclude that diffusion of oxygen in vitro is not limiting, allowing the development of tissue constructs on the order of centimeters in thickness. In addition, diffusion of fibroblast-derived soluble mediators is necessary for stable capillary formation, but is significantly impeded relative to that of nutrients present in the medium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
3D bioprinting of vascularized, heterogeneous cell-laden tissue constructs
Kolesky, D. B., Truby, R. L., Gladman, A. S., Busbee, T. A., Homan, K. A., & Lewis, J. A. (2014) · Advanced Materials · doi:10.1002/adma.201305506 · Cited by 2,102
Direct 3D bioprinting of perfusable vascular constructs using a blend bioink
Jia, W., Gungor-Ozkerim, P. S., Zhang, Y. S., Yue, K., Zhu, K., Liu, W., Pi, Q., Byambaa, B., Dokmeci, M. R., Shin, S. R., et al. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.07.038 · Cited by 922
Vascularization Strategies for Tissue Engineering
Lovett, M., Lee, K., Edwards, A., & Kaplan, D. L. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0085 · Cited by 923
The use of whole organ decellularization for the generation of a vascularized liver organoid
Baptista, P. M., Siddiqui, M. M., Lozier, G., Rodriguez, S. R., Atala, A., & Soker, S. (2011) · Hepatology · doi:10.1002/hep.24067 · Cited by 681
Advances in the formation, use and understanding of multi-cellular spheroids
Achilli, T.-M., Meyer, J., & Morgan, J. R. (2012) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.2012.707181 · Cited by 572
Metadata
- Authors
- Griffith, C. K., Miller, C., Sainson, R. C. A., Calvert, J. W., Jeon, N. L., Hughes, C. C. W., & George, S. C.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2005-01
- Volume
- 11
- Issue
- 1-2
- Pages
- 257-266
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2030426885
- Cited by
- 346
- References
- 0
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffusion Limits of an in Vitro Thick Prevascularized Tissue. https://app.cochat.ai/papers/10.1089/ten.2005.11.257
- The paper
- Griffith, C. K., Miller, C., Sainson, R. C. A., Calvert, J. W., Jeon, N. L., Hughes, C. C. W., & George, S. C. (2005). Diffusion Limits of an in Vitro Thick Prevascularized Tissue. Tissue Engineering. https://doi.org/10.1089/ten.2005.11.257
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.