CoChat

Characterizing Environmental Factors that Impact the Viability of Tissue-Engineered Constructs Fabricated by a Direct-Write Bioassembly Tool

Smith, Cynthia M., Christian, Joseph J., Warren, William L., Williams, Stuart K. · 2007 · Tissue Engineering
Cited by 116

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Tissue engineering combines the fields of medicine and engineering to build replacement tissue capable of restoring, maintaining, or improving damaged tissue. Researchers have recently developed techniques to fabricate tissue in which both the cells and matrix have a carefully defined architecture. This report details studies evaluating the use of a direct-write, 3-dimensional (3D) bioassembly tool (BAT) capable of extruding cells and matrix into spatially organized, 3D constructs. This system has been characterized by its ability to fabricate viable 2-dimensional and 3D constructs containing up to 2 separate cellular solutions suspended in type I collagen. The effects of various environmental factors, such as extrusion pressure, humidity, and stage heating, were examined with respect to the viability of the extruded cells. The data indicate that the system parameters required to extrude cells suspended in collagen do not adversely affect the viability of those cells. Maintaining a high humidity, especially when stage heat was applied, is critical in maintaining the viability of the printed cells. These results demonstrate that the BAT is capable of spatially organizing separate cellular solutions into a defined architecture; however, when cells were extruded in a supporting matrix of 3.0 mg/mL type I collagen, it was not possible to consistently generate adjacent, touching, but nonoverlapping lines of separate solutions. Thus, when a fabrication system such as BAT is used to generate complex, 3D viable constructs, the supporting matrix for the cells should be carefully chosen on the basis of such characteristics as its rate of polymerization and stiffness.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/ten.2006.0101

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 116

Metadata

Authors
Smith, C. M., Christian, J. J., Warren, W. L., & Williams, S. K.
Venue
Tissue Engineering
Published
2007-02
Volume
13
Issue
2
Pages
373-383
ISSN
  • 1076-3279 (ISSN-L)
  • 1557-8690
OpenAlex
W2047045486
Cited by
116
References
1
FWCI
3.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characterizing Environmental Factors that Impact the Viability of Tissue-Engineered Constructs Fabricated by a Direct-Write Bioassembly Tool. https://app.cochat.ai/papers/10.1089/ten.2006.0101
The paper
Smith, C. M., Christian, J. J., Warren, W. L., & Williams, S. K. (2007). Characterizing Environmental Factors that Impact the Viability of Tissue-Engineered Constructs Fabricated by a Direct-Write Bioassembly Tool. Tissue Engineering. https://doi.org/10.1089/ten.2006.0101

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.