Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 185

The DOI matches its Crossref record.

Repair of Large Articular Osteochondral Defects Using Hybrid Scaffolds and Bone Marrow-Derived Mesenchymal Stem Cells in a Rabbit Model

Shao, Xinxin, Goh, James C.H., Hutmacher, Dietmar W., Lee, Eng Hin, Zigang, Ge·2006·Tissue Engineering

Abstract

In order to evaluate the repair potential in large osteochondral defects on high load-bearing sites, a hybrid scaffold system was made of three-dimensional porous Polycaprolactone (PCL) scaffold for the cartilage and tricalcium phosphate-reinforced PCL for the bone portion. Osteochondral defects of 4-mm diameter x 5.5-mm depth were created in the medial femoral condyle of adult New Zealand White rabbits. The defects were treated with hybrid scaffolds without cells (control group) or seeded with allogenic bone marrow-derived mesenchymal stem cells (BMSC) in each part (experimental group) by press-fit implantation. Implanted cells were tracked using Adeno-LacZ labeling. Repair tissues were evaluated at 3 and 6 months after implantation. Overall, the experimental group showed superior repair results as compared to the control group using gross examination, qualitative and quantitative histology, and biomechanical assessment. With BMSC implantation, the hybrid scaffolds provided sufficient support to new osteochondral tissues formation. The bone regeneration was consistently good from 3 to 6 months with firm integration to the host tissue. Cartilage layer resurfacing was more complicated. All of the samples showed cartilage tissues mixed with PCL scaffold filaments at 3 months. Histology at 6 months revealed some degradation phenomenon in several samples whereas others had a good appearance; however, the Young's moduli from the experimental group (0.72 MPa) approached that of normal cartilage (0.81 MPa). In vivo viability of implanted cells was demonstrated by the retention for 6 weeks in the scaffolds. This investigation showed that PCL-based hybrid scaffolds with BMSC may be an alternative treatment for large osteochondral defects in high-loading sites.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/ten.2006.12.1539

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 185

Metadata

Authors
Shao, X., Goh, J. C. H., Hutmacher, D. W., Lee, E. H., & Zigang, G.
Venue
Tissue Engineering
Published
2006-06
Volume
12
Issue
6
Pages
1539-1551
ISSN
  • 1076-3279 (ISSN-L)
  • 1557-8690
OpenAlex
W2057459297
Cited by
185
References
0
FWCI
9.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Repair of Large Articular Osteochondral Defects Using Hybrid Scaffolds and Bone Marrow-Derived Mesenchymal Stem Cells in a Rabbit Model. https://app.cochat.ai/papers/10.1089/ten.2006.12.1539
The paper
Shao, X., Goh, J. C. H., Hutmacher, D. W., Lee, E. H., & Zigang, G. (2006). Repair of Large Articular Osteochondral Defects Using Hybrid Scaffolds and Bone Marrow-Derived Mesenchymal Stem Cells in a Rabbit Model. Tissue Engineering. https://doi.org/10.1089/ten.2006.12.1539

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.